Abstract

In order to get a marketing authorization, breast implants (BI) must meet a number of standard requirements. French and European standards ISO 14607 list a number of official tests to be performed before an implant can be used clinically. However, the BI material characteristics evolution over implantation time remains a research field which is unexplored. The goal of the present study is to compare the mechanical ageing of two breast implant generations and assess if the use of one generation rather than the other is advantageous in terms of durability. For that purpose, 21 explanted BI were analyzed in terms of biomechanical characteristics and compared. Twelve BI were textured anatomic specimens of 5th generation and 10 BI were round textured specimens of 4th generation. All the specimens were produced by the same manufacturer. Implantation time ranged from 3 to 130 months. Both the shell and the gel of every specimen were analyzed. Results show that the mechanical properties go down with the implantation time for all the implants. Moreover, the shell of round implants appear to be less resistant than the shell of anatomic specimens with 25% lower rupture forces. With regard to the gel, whatever the specimen, results show that the properties change with implantation time. The color changes from transparent to milky to finally become yellow, while the cohesion goes down especially for the round specimens. Globally, the study brings out that BI get degraded with implantation time and provides information which could help predicting the durability of the implant.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Breast Implant and Reconstruction · Reconstructive Surgery and Microvascular Techniques · Automotive and Human Injury Biomechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (21)

Show source-provided references
1. ANSM (Agence nationale de sécurité du médicament et des produits de santé), 2014. Evaluation of the Use of Silicone Breast Implants (other than PIP) in France 2010–2013 (Report).
2. Adams, W., Jr., Robinson, J., Rohrich, R., 1998. Lipid infiltration as a possible biologic cause of silicone gel breast implant aging. Plast. Reconstr. Surg. 101 (1), 64–68.10.1097/00006534-199801000-00011 ↗
3. Biodurability of retrieved silicone gel breast implants10.1097/01.PRS.0000060795.16982.1C ↗
4. Silicone technology for the plastic surgeon10.1016/S0094-1298(20)31386-9 ↗
5. Indications for the use of MemoryShape breast implants in aesthetic and reconstructive breast surgery: long-term clinical outcomes of shaped versus round silicone breast implants10.1097/PRS.0000000000000609 ↗
6. The biology and evolution of cohesive gel and shaped implants10.1097/PRS.0000000000000347 ↗
7. Mechanical analysis of explanted silicone breast implants10.1097/00006534-199608000-00008 ↗
8. Discussion: form stability of the style 410 anatomically shaped cohesive silicone gel-filled breast implant in subglandular breast augmentation evaluated with magnetic resonance imaging10.1097/PRS.0b013e3181fad403 ↗
9. Silicone gel breast implant failure: evaluation of properties of shells and gels for explanted prostheses and meta-analysis of literature rupture data10.1097/00000637-200209000-00001 ↗
10. Augmentation mammaplasty: general considerations
11. Natrelle style 410 form-stable silicone breast implants: core study results at 6 years10.1177/1090820X12452423 ↗
12. NF EN ISO 14607, 2009. Implants chirurgicaux non actifs – Implants mammaires – Exigences particulières, November 2009.
13. Failure of silicone gel breast implants: is the machanical weakening due to shell swelling a significant cause of prostheses rupture?10.1016/j.jmbbm.2011.06.019 ↗
14. Style 410 cohesive silicone breast implants: safety and effectiveness at 5 to 9 Years after implantation
15. Factors affecting the rupture of silicone-gel breast implants10.1097/00000637-199405000-00001 ↗
16. Analysis of explanted silicone implants: a report of 300 patients10.1097/00000637-199501000-00001 ↗
17. Natrelle round silicone breast implants: Core Study results at 10 years10.1097/PRS.0000000000000021 ↗
18. Inamed silicone breast implant core study results at 6 years10.1097/01.prs.0000286580.93214.df ↗
19. Pressure resistance of breast implants as a function of implantation time10.1097/00000637-198812000-00013 ↗
20. Chemical, physical and mechanical analysis of explanted breast implants
21. Surface and mechanical analysis of explanted poly implant prosthese silicone breast implants10.1002/bjs.9094 ↗