Minimizing specimen length in elastic testing of end-constrained cancellous bone
Source abstract
Abstract
End-constraint is needed when performing tensile and compressive testing of cancellous bone so that frictional and structural end-effects are minimized and the mechanical properties are not underestimated. Since many end-constrained testing techniques are limited to certain sites and species by the large specimen sizes required, reductions in overall specimen length would be advantageous. The following study examines the effect of specimen gauge length and aspect ratio on the elastic tensile testing of cancellous bone from the bovine femoral condyle. Three different nominal gauge lengths (10, 16, 22 mm) were examined at two different diameters (5.1, 10.7 mm) which bound the range typically used for cancellous bone testing. No effect of gauge length or aspect ratio was observed, but evidence of a diameter effect was noted. Three-dimensional finite element method (FEM) models confirmed the experimental observations and demonstrated that an overestimation of modulus begins to occur for specimens shorter than 10 mm.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Lower Extremity Biomechanics and Pathologies · Orthopedic Surgery and Rehabilitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. A comparison between cancellous bone compressive moduli determined from surface strain and total specimen deflection
2. Size effects in ductile cellular solids. Part II: Experimental results10.1016/S0020-7403(00)00043-6 ↗
3. Effect of sample geometry on the measurement of mechanical properties of anisotropic materials10.1016/0032-3861(76)90129-4 ↗
4. Elastic properties of cancellous bone: Measurement by an ultrasonic technique10.1016/0021-9290(87)90327-7 ↗
5. Inhomogeneity of human vertebral cancellous bone: Systematic density and structure patterns inside the vertebral body10.1016/S8756-3282(01)00425-2 ↗
6. Revised standard values for pH measurements from 0 to 95 ∘C10.6028/jres.066A.016 ↗
7. Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site10.1016/j.jbiomech.2007.05.008 ↗
8. Saint–Venant’s principle for a piezoelectric body10.1137/S0036139997319323 ↗
9. The compressive behaviour of bone as a two-phase porous structure10.2106/00004623-197759070-00021 ↗
10. Tensile fracture of cancellous bone10.3109/17453678008990868 ↗
11. Resistance of copper and copper alloys to homogeneous deformation in compression
12. Limitations of the continuum assumption in cancellous bone10.1016/0021-9290(88)90257-6 ↗
13. Mathematical relationships between bone density and mechanical properties: A literature review10.1016/j.clinbiomech.2007.08.024 ↗
14. Saint-Venant end effects in composites10.1177/002199838201600506 ↗
15. Tensile strength of bovine trabecular bone10.1016/0021-9290(85)90027-2 ↗
16. Theoretical analysis of the experimental artifact in trabecular bone compressive modulus10.1016/0021-9290(93)90021-6 ↗
17. Trabecular bone exhibits fully linear elastic behavior and yields at low strains10.1016/0021-9290(94)90053-1 ↗
18. Biomechanics of trabecular bone10.1146/annurev.bioeng.3.1.307 ↗
19. Systematic and random errors in compression testing of trabecular bone10.1002/jor.1100150115 ↗
20. Saint-Venant end effects for materials with negative Poisson’s ratios10.1115/1.2894037 ↗
21. Specimen size effect in the volumetric shrinkage of cancellous bone measured at two levels of dehydration10.1016/j.jbiomech.2006.09.002 ↗
22. The effect of constraint on the mechanical behaviour of trabecular bone specimens10.1016/0021-9290(89)90209-1 ↗
23. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens10.1016/0021-9290(92)90255-Y ↗
24. Time-lapsed microstructural imaging of bone failure behavior10.1016/S0021-9290(03)00254-9 ↗
25. Design and implementation of a novel mechanical testing system for cellular solids10.1002/jbm.b.30232 ↗
26. The interaction of microstructure and volume fraction in predicting failure in cancellous bone10.1016/j.bone.2006.06.013 ↗
27. Compressive axial strain distributions in cancellous bone specimens10.1016/0021-9290(89)90066-3 ↗
28. The underestimation of Young’s modulus in compressive testing of cancellous bone specimens10.1016/0021-9290(91)90333-I ↗
29. Size effects in ductile cellular solids. Part I: Modeling10.1016/S0020-7403(00)00042-4 ↗
30. Dependence of mechanical compressive strength on local variations in microarchitecture in cancellous bone of proximal human femur10.1016/j.jbiomech.2007.08.003 ↗
31. On the dependence of the elasticity and strength of cancellous bone on apparent density10.1016/0021-9290(88)90008-5 ↗
32. Tensile and compressive properties of cancellous bone10.1016/0021-9290(91)90006-9 ↗
33. Decay rates for the hollow circular cylinder10.1115/1.2894038 ↗
34. Structural and radiological parameters for the characterization of jawbone10.1111/j.1600-0501.2005.01204.x ↗
35. Saint-Venant’s principle10.1007/BF00282253 ↗
36. The effects of side-artifacts on the elastic modulus of trabecular bone10.1016/j.jbiomech.2006.05.012 ↗
37. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
38. Effects of specimen load-bearing and free surface layers on the compressive mechanical properties of cellular materials10.1016/0021-9290(94)90032-9 ↗