journal article·2019-08

Effects of loading rate on the of mechanical behavior of the femur in falling condition

Sina Askarinejad, Joshua E. Johnson, Nima Rahbar, Karen L. Troy

Publisher page

Abstract

The Surgeon General estimates that by 2020, half of all Americans could have weak bones due to bone loss. Osteoporosis causes more than 1.5 million fractures every year. Identifying effective interventions based on individual patient characteristics remains a major challenge. Proximal femur fractures are common and devastating events for individuals with osteoporosis. Since fracture is primarily a mechanical event, noninvasive predictions of fracture strength and location would be useful both for identifying at-risk individuals and evaluating treatment effects. However, bone fracture prediction is complicated due to the complex microstructure and nanostructure of bone. Bone is a highly heterogeneous material with rate-dependent mechanical behavior and large inter-individual variation. In this study, we designed two mechanical test procedures to understand the mechanical response of bone under impact and quasi-static load tests. The boundary conditions of the tests were designed in a way to simulate a fall to the side. The present study consists of three main parts: cadaver testing, quantitative image analysis, and finite element (FE) modeling. We obtained ten human femur bones and used high-resolution CT to quantify the microstructure and density of each sample. Specimen-specific FE models were created to evaluate the ability of various failure criteria to predict experimental fracture. Afterward, the samples were tested and their failure patterns were recorded. The fractured samples were rescanned to analyze the fractured surfaces. Our experimental results show that the loading necessary to fracture the femur samples is much higher in the impact tests. However, the toughening mechanisms are more pronounced in quasi-static tests. We found that FE model formulations were able to accurately predict femur stiffness and strength for quasi-static and impact conditions separately, but that no single formulation could account for the rate-dependent outcomes.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Bone health and osteoporosis research · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Toughening mechanisms in bioinspired multilayered materials10.1098/rsif.2014.0855 ↗
2. Predicting surface strains at the human distal radius during an in vivo loading task finite element model validation and application10.1016/j.jbiomech.2014.04.050 ↗
3. The compressive behavior of bone as a two-phase porous structure10.2106/00004623-197759070-00021 ↗
4. Femoral strength is better predicted by finite element models than QCT and DXA10.1016/S0021-9290(99)00099-8 ↗
5. The response of compact bone in tension at various strain rates10.1007/BF02368492 ↗
6. Factors associated with proximal femur fracture determined in a large cadaveric cohort10.1016/j.bone.2018.08.005 ↗
7. Finite element prediction of surface strain and fracture strength at the distal radius10.1016/j.medengphy.2011.07.016 ↗
8. Bone mineral loss at the proximal femur in acute spinal cord injury10.1007/s00198-013-2323-8 ↗
9. Bone mineral loss at the proximal femur in acute spinal cord injury10.1007/s00198-013-2323-8 ↗
10. Reduction in proximal femoral strength in patients with acute spinal cord injury10.1002/jbmr.2227 ↗
11. Relationship between the duration of paralysis and bone structure: a pQCT study of spinal cord injured individuals10.1016/j.bone.2004.01.001 ↗
12. Bone's mechanostat: a 2003 update10.1002/ar.a.10119 ↗
13. Measurement of impact force, simulation of fall and hip fracture10.1016/S1350-4533(97)00041-6 ↗
14. Accuracy of finite element predictions in sideways load configurations for the proximal human femur10.1016/j.jbiomech.2011.10.019 ↗
15. Strain gradients correlate with sites of periosteal bone formation10.1359/jbmr.1997.12.6.982 ↗
16. The mechanobiology of cancellous bone structural adaptation
17. Osteoporosis after spinal cord injury10.1007/s00198-005-2028-8 ↗
18. Static and dynamic finite element analyses of an idealized structural model of vertebral trabecular bone10.1115/1.2798311 ↗
19. On shear properties of trabecular bone under torsional loading: effects of bone marrow and strain rate10.1016/j.jbiomech.2007.03.008 ↗
20. Biomechanics of trabecular bone10.1146/annurev.bioeng.3.1.307 ↗
21. Femoral bone strength and its relation to cortical and trabecular changes after treatment with PTH, alendronate, and their combination as assessed by finite element analysis of quantitative CT scans10.1359/jbmr.080805 ↗
22. Prediction of femoral fracture load using finite element models: an examination of stress-and strin-based failure theories10.1016/S0021-9290(99)00152-9 ↗
23. Adaptation of the proximal femur to skeletal reloading after long‐duration spaceflight10.1359/jbmr.060509 ↗
24. Mechanical properties of trabecular bone. Dependency on strain rate10.1016/0021-9290(91)90305-7 ↗
25. Computational investigation of ultrastructural behavior of bone using a cohesive finite element approach
26. Bone volume fraction and fabric anisotropy are better determinants of trabecular bone stiffness than other morphological variables10.1002/jbmr.2437 ↗
27. Trabecular bone modulus-density relationships depend on anatomic site10.1016/S0021-9290(03)00071-X ↗
28. The effect of intertrabecular fluid on femoral head mechanics
29. Mate- rial properties of femoral cancellous bone in axial loading10.1007/BF00450930 ↗
30. Wavelet based qualitative assessment of femur bone strength using radiographic imaging. World Academy of Science, Engineering and Technology
31. Bone trabecular analysis of femur radiographs for the assessment of osteoporosis using DWT and DXA10.7763/IJCTE.2013.V5.760 ↗
32. Mechanical properties of human cancellous bone in the femoral head
33. Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis10.2106/00004623-197052030-00005 ↗
34. Off-axis loads cause failure of the distal radius at lower magnitudes than axial loads: a finite element analysis10.1016/j.jbiomech.2007.01.018 ↗
35. Ungural · 1995
36. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur10.1016/S0021-9290(00)00069-5 ↗
37. Fracture mechanics parameters for compact bone effects of density and specimen thickness10.1016/0021-9290(77)90019-7 ↗
38. Wright · 2017