journal article·2011-10

Mechanical and biodegradable properties of porous titanium filled with poly-L-lactic acid by modified in situ polymerization technique

Masaaki Nakai, Mitsuo Niinomi, Daisuke Ishii

Publisher page

Abstract

Porous titanium (pTi) can possess a low Young's modulus equal to that of human bone, depending on its porosity. However, the mechanical strength of pTi deteriorates greatly with increasing porosity. On the other hand, certain medical polymers exhibit biofunctionalities, which are not possessed intrinsically by metallic materials. Therefore, a biodegradable medical polymer, poly-L-lactic acid (PLLA), was used to fill in the pTi pores using a modified in-situ polymerization technique. The mechanical and biodegradable properties of pTi filled with PLLA (pTi/PLLA) as fabricated by this technique and the effects of the PLLA filling were evaluated in this study. The pTi pores are almost completely filled with PLLA by the developed process (i.e., technique). The tensile strength and tensile Young's modulus of pTi barely changes with the PLLA filling. However, the PLLA filling improves the compressive 0.2% proof stress of pTi having any porosity and increases the compressive Young's modulus of pTi having relatively high porosity. This difference between the tensile and compressive properties of pTi/PLLA is considered to be caused by the differing resistances of PLLA in the pores to tensile and compressive deformations. The PLLA filled into the pTi pores degrades during immersion in Hanks' solution at 310 K. The weight loss due to PLLA degradation increases with increasing immersion time. However, the rate of weight loss of pTi/PLLA during immersion decreases with increasing immersion time. Hydroxyapatite formation is observed on the surface of pTi/PLLA after immersion for ≥8 weeks. The decrease in the weight-loss rate may be caused by weight gain due to hydroxyapatite formation and/or the decrease in contact area with Hanks' solution caused by its formation on the surface of pTi/PLLA.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. A new low modulus, biocompatible titanium alloy
2. Can bioactivity be tested in vitro with SBF solution?10.1016/j.biomaterials.2009.01.008 ↗
3. The rate of bone ingrowth into porous metal10.1002/jbm.820100210 ↗
5. Titanium with controllable pore fractions by thermoreversible gelcasting of TiH210.1016/j.actamat.2008.06.035 ↗
6. Processing of titanium foams using magnesium spacer particles10.1016/j.scriptamat.2006.11.010 ↗
7. Effect of Zr and Sn on Young’s modulus and superelasticity of Ti–Nb-based alloys10.1016/j.msea.2006.09.051 ↗
8. Honda · 1961
9. Environmental crazing and intrinsic tensile deformation in polymethylmethacrylate Part 1 Mechanical behaviour10.1007/BF00540922 ↗
10. Implant fixation by bone ingrowth10.1016/S0883-5403(99)90063-3 ↗
11. Design and mechanical properties of new β type titanium alloys for implant materials10.1016/S0921-5093(97)00808-3 ↗
12. Beta TiNbSn alloys with low Young’s modulus and high strength10.2320/matertrans.46.1070 ↗
13. Effect of initial preform porosity on solid-state foaming of titanium10.1557/jmr.2006.0140 ↗
14. Effect of medical polymer filling on tensile properties of biomedical porous pure titanium10.2497/jjspm.55.312 ↗
15. Effect of silane coupling treatment on mechanical properties of porous pure titanium filled with PMMA for biomedical applications10.2320/jinstmet.72.839 ↗
16. Development of biomedical porous titanium filled with medical polymer by in-situ polymerization of monomer solution infiltrated into pores10.1016/j.jmbbm.2009.03.003 ↗
17. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
18. Microstructures and mechanical properties of porous titanium compacts prepared by powder sintering10.2320/matertrans.43.443 ↗
19. Mechanical properties of porous titanium compacts prepared by powder sintering10.1016/j.scriptamat.2003.08.018 ↗
20. Production of titanium porous material “Tiporous” and its evaluation10.4028/www.scientific.net/MSF.534-536.993 ↗
21. Fabrication methods of porous metals for use in orthopaedic applications10.1016/j.biomaterials.2005.12.002 ↗
22. Multifunctional alloys obtained via a dislocation-free plastic deformation mechanism10.1126/science.1081957 ↗
23. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids10.1016/S0142-9612(03)00372-7 ↗
24. Manufacturing technique of titanium powders by gas atomizing process10.2320/materia.34.792 ↗
25. Experiment study on fracture fixation with low rigidity titanium alloy10.1007/s10856-008-3372-y ↗
26. Time-dependent failure of poly(methyl methacrylate)10.1016/0032-3861(76)90215-9 ↗