Numerical and experimental investigations for the evaluation of the wear coefficient of reverse total shoulder prostheses
Source abstract
Abstract
In the present study, numerical and experimental wear investigations on reverse total shoulder arthroplasties (RTSAs) were combined in order to estimate specific wear coefficients, currently not available in the literature. A wear model previously developed by the authors for metal-on-plastic hip implants was adapted to RTSAs and applied in a double direction: firstly, to evaluate specific wear coefficients for RTSAs from experimental results and secondly, to predict wear distribution. In both cases, the Archard wear law (AR) and the wear law of UHMWPE (PE) were considered, assuming four different k functions. The results indicated that both the wear laws predict higher wear coefficients for RTSA with respect to hip implants, particularly the AR law, with k values higher than twofold the hip ones. Such differences can significantly affect predictive wear model results for RTSA, when non-specific wear coefficients are used. Moreover, the wear maps simulated with the two laws are markedly different, although providing the same wear volume. A higher wear depth (+51%) is obtained with the AR law, located at the dome of the cup, while with the PE law the most worn region is close to the edge. Taking advantage of the linear trend of experimental volume losses, the wear coefficients obtained with the AR law should be valid despite having neglected the geometry update in the model.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Shoulder Injury and Treatment · Orthopaedic implants and arthroplasty · Shoulder and Clavicle Injuries
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (45)
Show source-provided references
1. Computational wear prediction of artificial knee joints based on a new wear law and formulation10.1016/j.jbiomech.2011.01.027 ↗
2. Muscle and joint-contact loading at the glenohumeral joint after reverse total shoulder arthroplasty10.1002/jor.21437 ↗
3. Barbour, P.S.M., Barton, R.C., Fisher, N., 1995. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses. In: Proceedings of the 10th International Conference on Wear of Materials (1st ed.). Wear, Switzerland, pp. 250–257.10.1016/0043-1648(95)90031-4 ↗
4. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants10.1115/1.3138543 ↗
5. In vivo gleno-humeral joint loads during forward flexion and abduction10.1016/j.jbiomech.2011.02.142 ↗
6. Grammont reverse prosthesis: design, rationale, and biomechanics10.1016/j.jse.2004.10.006 ↗
7. Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching10.1016/j.jse.2009.01.015 ↗
8. Friction of total hip replacements with different bearings and loading conditions10.1002/jbm.b.30691 ↗
9. Biotribology of artificial hip joints10.5312/wjo.v6.i1.77 ↗
10. A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants10.1016/j.triboint.2014.10.023 ↗
11. Reverse total shoulder arthroplasty—from the most to the least common complication10.1007/s00264-010-1125-2 ↗
12. Wear of crosslinked UHMWPE in a hip joint simulator
13. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations10.1243/09544119JEIM99 ↗
14. Wear in the prosthetic shoulder: association with design parameters10.1115/1.2486060 ↗
15. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure10.1243/09544119JEIM431 ↗
16. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE10.1016/j.jbiomech.2007.09.005 ↗
17. Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter10.1016/j.jbiomech.2009.01.005 ↗
18. Wear-induced loss of mass in reversed total shoulder arthroplasty with conventional and inverted bearing materials10.1016/j.jbiomech.2011.11.055 ↗
19. Kontaxis · 2010
20. Analysis of reverse total shoulder joint forces and glenoid fixation
21. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion10.1016/j.jse.2014.10.018 ↗
22. A new formulation for the prediction of polyethylene wear in artificial hip joints10.1243/09544119JEIM819 ↗
23. Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing10.1243/095441103765212703 ↗
24. Glenohumeral contact forces in reversed anatomy shoulder replacement10.1016/j.jbiomech.2010.05.024 ↗
25. Influence of the wear partition factor on wear evolution modelling of sliding surfaces10.1016/j.ijmecsci.2015.03.022 ↗
26. A comparative study on wear laws for soft-on-hard hip implants using a mathematical wear model10.1016/j.triboint.2012.03.002 ↗
27. Finite element analysis of acetabular wear. Validation, and fixation and backing effects10.1097/00003086-199711000-00012 ↗
28. Reverse total shoulder arthroplasty: current concepts, results, and component wear analysis10.2106/JBJS.J.00769 ↗
29. Analysis of a retrieved Delta III total shoulder prosthesis10.1302/0301-620X.86B8.15228 ↗
30. Quantifying cross-shear under translation, rolling, and rotation, and its effect on UHMWPE wear10.1016/j.wear.2014.03.001 ↗
31. Wear rates of highly cross-linked polyethylene humeral liners subjected to alternating cycles of glenohumeral flexion and abduction10.1016/j.jse.2014.05.001 ↗
32. Computational analysis of polyethylene wear in anatomical and reverse shoulder prostheses10.1007/s11517-014-1221-3 ↗
33. Wear analysis in anatomical and reversed shoulder prostheses10.1080/10255842.2010.499868 ↗
34. Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding10.1243/09544119JEIM146 ↗
35. In vitro wear testing of a contemporary design of reverse shoulder prosthesis10.1016/j.jbiomech.2015.07.022 ↗
36. First wear results from a unique multi-station shoulder joint simulator
37. Simulated joint and muscle forces in reversed and anatomic shoulder prostheses10.1302/0301-620X.90B6.19708 ↗
38. Comparison of polyethylene wear in anatomical and reversed shoulder prostheses10.1302/0301-620X.91B7.21999 ↗
39. Quantification of the effect of cross-path motion on the wear rate of ultra-high molecular weight polyethylene10.1016/S0043-1648(03)00357-0 ↗
40. Wear simulation of reverse total shoulder arthroplasty systems: effect of glenosphere design10.1016/j.jse.2011.10.024 ↗
41. A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding10.1016/S0043-1648(00)00522-6 ↗
42. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement
43. Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene10.1016/S0043-1648(96)07362-0 ↗
44. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces10.1243/09544110360729117 ↗
45. The evaluation of the failed shoulder arthroplasty10.1016/j.jse.2013.12.003 ↗