Deformation mechanisms of prototype composite braided stent-grafts in bending fatigue for peripheral artery application
Source abstract
Abstract
Stent-grafts in peripheral arteries suffer from complex cyclic loadings in vivo, including pulsatile, axial bending and torsion. Normal fatigue durability evaluation technologies, however, are majorly based on pulsation and thus are short of accuracy under the complicated stress conditions experienced physiologically. While there is a little research focused on the cyclic fatigue of stent-grafts in bending, it remains an almost total lack of deformation or fatigue mechanisms. In this work, composite braided stent-grafts incorporating Nitinol (NiTi) yarns and polyethylene terephthalate (PET) multifilament yarns were cycled in bending by the self-developed testing system to investigate their deformation behaviors. Deformation mechanisms at the yarn level were discussed, and NiTi yarn crossover structure was considered the primary factor affecting the deformation modes. Four yarn-crossover-based deformation modes (accordion buckling, diamond-shaped buckling, neck propagation and microbuckling) revealed the mechanisms of energy absorption of braided stent-grafts on the mesoscopic scale. Further, mechanical modes were applied to help regulate stent designs.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Tissue Engineering and Regenerative Medicine · Aortic Disease and Treatment Approaches
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. FDA recommendations for nitinol stent and endovascular graft fatigue characterization and fracture reporting10.1520/JAI100384 ↗
2. Antibacterial surgical silk sutures using a high-performance slow-release carrier coating system10.1021/acsami.5b06239 ↗
3. The effect of aging on deformations of the superficial femoral artery resulting from hip and knee flexion: potential clinical implications10.1016/j.jvir.2009.08.027 ↗
4. In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion10.1097/01.RVI.0000220367.62137.E8 ↗
5. An energy model of yarn bending10.1533/joti.2005.0212 ↗
6. Analysis of yarn bending behaviour
7. A new approach to improve the local compressive properties of PPDO self-expandable stent10.1016/j.jmbbm.2017.02.015 ↗
8. In-vivo imaging of femoral artery nitinol stents for deformation analysis10.1016/j.jvir.2010.10.019 ↗
9. Deformation and failure mechanisms of braided composite tubes in compression and torsion10.1016/S1359-6454(99)00427-9 ↗
10. In vitro evaluation of the radial and axial force of self-expanding esophageal stents10.1055/s-0033-1344985 ↗
11. Energy dissipation in the course of the fatigue degradation: mathematical derivation and experimental quantification10.1016/j.ijsolstr.2015.06.032 ↗
12. Large deformation bending analysis of functionally graded spherical shell using FEM10.12989/sem.2015.53.4.661 ↗
13. Thermoelastic analysis of functionally graded doubly curved shell panels using nonlinear finite element method10.1016/j.compstruct.2015.04.006 ↗
14. Biomechanical incompatibility of popliteal stent placement10.1583/04-127.1 ↗
15. Stent fracture associated with drug-eluting stents: clinical characteristics and implications
16. An in vitro twist fatigue test of fabric stent-grafts supported by Z-stents vs. ringed stents10.3390/ma9020113 ↗
17. Efficient and accurate simulation of the rope–sheave interaction in weight-lifting machines
18. Large amplitude bending behaviour of laminated composite curved panels10.1108/EC-05-2014-0119 ↗
19. NiTi fatigue behavior10.1063/1.328738 ↗
20. Fatigue of NITI thermoelastic martensites10.1016/0001-6160(79)90065-8 ↗
21. A mathematical model to predict the in vivo pulsatile drag forces acting on bifurcated stent grafts used in endovascular treatment of abdominal aortic aneurysms (AAA)10.1016/j.jbiomech.2003.11.014 ↗
22. Fracture of self-expanding nitinol stents stressed in vitro under simulated intravascular conditions10.1016/j.jvs.2008.02.029 ↗
23. Fatigue and durability of Nitinol stents10.1016/j.jmbbm.2007.08.001 ↗
24. Reinoehl, M., Bradley, D., Bouthot, R., Proft, J. The Influence of Melt Pracyice on Final Fatigue Properties of Superelastic NiTi Wires. 2000; pp 397–403.
25. Prevalence and clinical impact of stent fractures after femoropopliteal stenting10.1016/j.jacc.2004.11.026 ↗
26. Nonlinear flexural analysis of single/doubly curved smart composite shell panels integrated with PFRC actuator10.1016/j.euromechsol.2016.08.006 ↗
27. Timoshenko · 1936 · 220
28. Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation10.1016/j.ijcard.2007.12.067 ↗
29. Finite element simulation of the mechanical behavior of synthetic braided ropes and validation on a tensile test10.1016/j.ijsolstr.2014.12.022 ↗
30. On the nature of multiple melting in poly(ethylene terephthalate) (PET) and cyclohexylene dimethylene (PET/CT) coplymer
31. Mechanical response of cardiovascular stents under vascular dynamic bending10.1186/s12938-016-0135-8 ↗
32. Design and mechanical behaviors of sutureless prototype composite nitinol stent-grafts