Regional and depth variability of porcine meniscal mechanical properties through biaxial testing
Source abstract
Abstract
The menisci in the knee joint undergo complex loading in-vivo resulting in a multidirectional stress distribution. Extensive mechanical testing has been conducted to investigate the tissue properties of the knee meniscus, but the testing conditions do not replicate this complex loading regime. Biaxial testing involves loading tissue along two different directions simultaneously, which more accurately simulates physiologic loading conditions. The purpose of this study was to report mechanical properties of meniscal tissue resulting from biaxial testing, while simultaneously investigating regional variations in properties. Ten left, fresh porcine joints were obtained, and the medial and lateral menisci were harvested from each joint (twenty menisci total). Each menisci was divided into an anterior, middle and posterior region; and three slices (femoral, deep and tibial layers) were obtained from each region. Biaxial and constrained uniaxial testing was performed on each specimen, and Young's moduli were calculated from the resulting stress strain curves. Results illustrated significant differences in regional mechanical properties, with the medial anterior (Young's modulus (E)=11.14 ± 1.10 MPa), lateral anterior (E=11.54 ± 1.10 MPa) and lateral posterior (E=9.0 ± 1.2 MPa) regions exhibiting the highest properties compared to the medial central (E=5.0 ± 1.22 MPa), medial posterior (E=4.16 ± 1.13 MPa) and lateral central (E=5.6 ± 1.20 MPa) regions. Differences with depth were also significant on the lateral meniscus, with the femoral (E=12.7 ± 1.22 MPa) and tibial (E=8.6 ± 1.22 MPa) layers exhibiting the highest Young's moduli. This data may form the basis for future modeling of meniscal tissue, or may aid in the design of synthetic replacement alternatives.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Lower Extremity Biomechanics and Pathologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Regional and fiber orientation dependent shear properties and anisotropy of bovine meniscus10.1016/j.jmbbm.2011.06.022 ↗
2. Importance of the medial meniscus in the anterior cruciate ligament-deficient knee10.1002/jor.1100180116 ↗
3. The meniscus: structure, function, repair, and replacement
4. The effect of complete radial lateral meniscus posterior root tear on the knee contact mechanics: a finite element analysis10.1007/s00776-012-0334-5 ↗
5. Functional characterization of normal and degraded bovine meniscus: rate-dependent indentation and friction studies10.1016/j.bone.2012.03.009 ↗
6. Displacements of the menisci under joint load: an in vitro study in human knees10.1016/0021-9290(94)90018-3 ↗
7. Quantification of the transverse carpal ligament elastic properties by sex and region10.1016/j.clinbiomech.2014.05.003 ↗
8. The effect of meniscal tears and resultant partial meniscectomies on the knee contact stresses: a finite element analysis10.1080/10255842.2012.753063 ↗
9. Biaxial mechanical testing of human sclera10.1016/j.jbiomech.2010.02.031 ↗
10. Farinaccio · 1989
11. Biphasic mechanical properties of the knee meniscus
12. Material properties and structure-function relationships in the menisci10.1097/00003086-199003000-00004 ↗
13. A comparison of uniaxial and biaxial mechanical properties of the annulus fibrosus: a porcine model10.1115/1.4003327 ↗
14. Methodology and apparatus to determine material properties of the knee joint meniscus10.1016/S1350-4533(97)00011-8 ↗
15. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint10.1016/S0021-9290(02)00305-6 ↗
16. Biomechanical properties of the transverse carpal ligament under biaxial strain10.1002/jor.21583 ↗
17. Restoration of the meniscus form and function10.1177/0363546513498503 ↗
18. The effects of multiple freeze–thaw cycles on the biomechanical properties of the human bone-patellar tendon-bone allograft10.1002/jor.21373 ↗
19. Is the circumferential tensile modulus within a human medial meniscus affected by the test sample location and cross-sectional area?10.1002/jor.1100180614 ↗
20. Thickness measurement of soft tissue biomaterials: a comparison of five methods10.1016/0021-9290(95)00121-2 ↗
21. Effects of radial tears and partial meniscectomy of lateral meniscus on the knee joint mechanics during the stance phase of the gait cycle—a 3D finite element study10.1002/jor.22358 ↗
22. Structure and function relationships of the meniscus in the knee
23. Indentation properties and glycosaminoglycan content of human menisci in the deep zone10.1016/j.actbio.2012.12.033 ↗
24. Collagenous fibril texture of the human knee joint menisci10.1007/s004290050141 ↗
25. Material properties of the normal medial bovine meniscus10.1002/jor.1100070602 ↗
26. Role of the meniscus in the distribution of stress in the knee10.1097/00003086-198405000-00046 ↗
27. Osteoarthritis after arthroscopic partial meniscectomy10.1177/036354659502300219 ↗
28. New developments in osteoarthritis. Prevention of injury-related knee osteoarthritis: opportunities for the primary and secondary prevention of knee osteoarthritis10.1186/ar3113 ↗
29. A method for planar biaxial testing that includes in-plane shear10.1115/1.2835086 ↗
30. Sanchez-Adams · Regional variation in the mechanical role of the knee meniscus glycosaminoglycans, J. App. Phys. · 2011 · 111 · 1590
31. Radial tie fibers influence the tensile properties of the bovine medial meniscus10.1002/jor.1100120205 ↗
32. Repeated freeze-thaw cycles do not alter biomechanics properties of fibular allograft bone10.1007/s11999-011-2033-5 ↗
33. Meniscal scaffolds: early experience and review of the literature10.1016/j.knee.2012.01.006 ↗
34. Tensile stress–strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
35. Multiview robotic microscope reveals the in-plane kinematics of amphibian neurulation10.1007/s10439-005-3309-2 ↗
36. The role of the menisci in force transmission across the knee10.1097/00003086-197506000-00027 ↗
37. Anisotropic and zonal variations in the tensile properties of the meniscus
38. Collagen crosslinking of human and porcine sclera10.1016/j.jcrs.2003.11.032 ↗