journal article·2014-03

Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles

Toru Moro, Masayuki Kyomoto, Kazuhiko Ishihara, Kenichi Saiga, Masami Hashimoto, Sakae Tanaka, Hideya Ito, Takeyuki Tanaka, Hirofumi Oshima, Hiroshi Kawaguchi, Yoshio Takatori

Publisher page

Abstract

Despite improvements in the techniques, materials, and fixation of total hip arthroplasty, periprosthetic osteolysis, a complication that arises from this clinical procedure and causes aseptic loosening, is considered to be a major clinical problem associated with total hip arthroplasty. With the objective of reducing the production of wear particles and eliminating periprosthetic osteolysis, we prepared a novel hip polyethylene (PE) liner whose surface graft was made of a biocompatible phospholipid polymer-poly(2-methacryloyloxyethyl phosphorylcholine (MPC)). This study investigated the wear resistance of the poly(MPC)-grafted cross-linked PE (CLPE; MPC-CLPE) liner during 15×10(6) cycles of loading in a hip joint simulator. The gravimetric analysis showed that the wear of the acetabular liner was dramatically suppressed in the MPC-CLPE liner, as compared to that in the non-treated CLPE liner. Analyses of the MPC-CLPE liner surface revealed that it suffered from no or very little wear even after the simulator test, whereas the CLPE liners suffered from substantial wears. The scanning electron microscope (SEM) analysis of the wear particles isolated from the lubricants showed that poly(MPC) grafting dramatically decreased the total number, area, and volume of the wear particles. However, there was no significant difference in the particle size distributions, and, in particular, from the SEM image, it was observed that particles with diameters less than 0.50μm were present in the range of the highest frequency. In addition, there were no significant differences in the particle size descriptors and particle shape descriptors. The results obtained in this study show that poly(MPC) grafting markedly reduces the production of wear particles from CLPE liners, without affecting the size of the particles. These results suggest that poly(MPC) grafting is a promising technique for increasing the longevity of artificial hip joints.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. The epidemiology of revision total hip arthroplasty in the United States
2. How have alternative bearings (such as metal-on-metal, highly cross-linked polyethylene, and ceramic-on-ceramic) affected the prevention and treatment of osteolysis?10.5435/00124635-200800001-00008 ↗
3. Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements10.1243/PIME_PROC_1996_210_409_02 ↗
4. Biologic activity of wear particles
5. Arthroplasty of the hip. A new operation10.1016/S0140-6736(61)92063-3 ↗
6. The effect of ultra-high molecular weight polyethylene wear debris on MG63 osteosarcoma cells in vitro
7. The basis for a second-generation highly cross-linked UHMWPE10.1097/01.blo.0000238856.61862.7d ↗
8. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns10.1097/01.blo.0000148783.20469.4c ↗
9. Early osteolysis with Hylamer acetabular liners10.1016/S0883-5403(98)90016-X ↗
10. Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis10.1097/01.blo.0000149821.72760.39 ↗
11. Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty10.3109/17453674.2010.519169 ↗
12. Hylamer vs conventional polyethylene in primary total hip arthroplasty: a long-term case-control study of wear rates and osteolysis10.1016/j.arth.2009.02.006 ↗
13. Photoinduced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on polyethylene membrane surface for obtaining blood cell adhesion resistance10.1016/S0927-7765(99)00158-7 ↗
14. Preparation of phospholipid polymers and their properties as polymer hydrogel membrane10.1295/polymj.22.355 ↗
15. Osteolysis: basic science10.1097/00003086-200112000-00008 ↗
16. Wear and osteolysis in total joint replacements
17. In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system10.1046/j.1525-1594.2003.t01-2-06993.x ↗
18. Structure of water in the vicinity of phospholipid analogue copolymers as studied by vibrational spectroscopy10.1021/la0349673 ↗
19. Early mobilization after protamine reversal of heparin following implantation of phosphorylcholine-coated stents in totally occluded coronary arteries10.1016/S0002-9149(99)00843-7 ↗
20. Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints
21. Enhanced wear resistance of orthopaedic bearing due to the cross-linking of poly(MPC) graft chains induced by gamma-ray irradiation10.1002/jbm.b.30874 ↗
22. Cartilage-mimicking, high-density brush structure improves wear resistance of crosslinked polyethylene: a pilot study10.1007/s11999-010-1718-5 ↗
23. Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: comparisons with the effect of polyethylene cross-linking and ceramic femoral heads10.1016/j.biomaterials.2009.02.020 ↗
24. Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis10.1038/nmat1233 ↗
25. 2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints10.1097/01.blo.0000246553.33434.5f ↗
26. Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints10.1016/j.joca.2010.05.019 ↗
27. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award10.1054/arth.2001.20540 ↗
28. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E10.1016/j.arth.2005.07.009 ↗
29. Biological evaluation and drug delivery application of cationically modified phospholipid polymers10.1016/j.biomaterials.2003.12.034 ↗
30. Forces transmitted by joints in the human body
31. Phosphorylcholine impairs susceptibility to biofilm formation of hydrogel contact lenses10.1016/j.ajo.2008.07.032 ↗
32. Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners10.1007/s11999-010-1555-6 ↗
33. Preclinical biocompatibility assessment of the EVAHEART ventricular assist device: coating comparison and platelet activation10.1002/jbm.a.31006 ↗
34. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators10.1002/jbm.a.30824 ↗