Failure analysis of retrieved PE-UHMW acetabular liners
Source abstract
Abstract
Ultra-high molecular weight polyethylene (PE-UHMW) acetabular liners have a limited lifespan in a patient's body. There are many factors affecting the performance of the implant and furthermore the properties of the polymeric material are changing after implantation. In this work material changes according to structure and morphology and their implication on mechanical properties are in focus. The physical and mechanical properties of ten crosslinked (xL) PE-UHMW and nine conventional (conv) gamma-sterilized PE-UHMW hip components, used as sliding surface in total hip joint replacement, with different in-vivo times are compared. The evaluation of the retrieved acetabular liners is performed in view of crosslinking and conventional gamma-sterilization but also in terms of the influence of gender concerning alteration in properties. The oxidative degradation in the PE-UHMW is investigated by means of Fourier Transformed Infrared Spectroscopy (FTIR). The characterization of the morphology is carried out via differential scanning calorimetry (DSC). A depth profile of the micro-hardness and elastic modulus is taken over the cross-section of the components in order to find the influence of chemical constitution and morphology on the micro-mechanical properties. It could be shown that crosslinking and oxidative degradation influence the degree of crystallinity of the polymer. Oxidation occurs for both types of the material due to in-vivo time. Higher degree of crystallinity can be correlated to higher hardness and indentation modulus. No unequivocal superiority of crosslinked over conventional liners can be observed. The influence of sex concerning alteration of the evaluated properties matters but need to be further investigated.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. Influence of different sterilization procedures on the morphological parameters and mechanical properties of ultra-high-molecular-weight polyethylene10.1002/app.31437 ↗
2. ASTM F2381-04: Standard Test Method for Evaluating Trans-vinylene Yield in Irradiated UHMWPE Fabricated forms Intended for Surgical Implants by Infrared Spectroscopy.
3. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene10.1002/jbm.a.10606 ↗
4. Kinetics of olefin oxidation10.1039/qr9490300001 ↗
5. UHMWPE for arthroplasty: past or future?10.1007/s10195-008-0038-y ↗
6. Gender-specific knees10.1503/cmaj.061696 ↗
7. Gender differences in walking and running on level and inclined surfaces10.1016/j.clinbiomech.2008.07.011 ↗
8. Comparison of cross-linked polyethylene materials for orthopaedic applications10.1097/01.blo.0000073343.50837.03 ↗
9. Analysis of products diffused into PE-UHMW prosthetic components in vivo10.1016/S0142-9612(00)00182-4 ↗
10. Total hip arthroplasty, state of the art for the 21st centrury10.1007/s00264-011-1207-9 ↗
11. Impact of chronic kidney disease stage on lower-extremity arthroplasty10.3928/01477447-20140626-51 ↗
12. Dumbelton · 2009
13. Gender differences in lower extremity mechanics during running10.1016/S0268-0033(03)00025-1 ↗
14. MALDI-TOF mass spectrometry imaging reveals molecular level changes in ultrahigh molecular weight polyethylene joint implants in correlation with lipid adsorption10.1021/ac5025232 ↗
15. Hip disease and the prognosis of total hip replacements: a review of 53698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-9910.1302/0301-620X.83B4.0830579 ↗
16. Clinical fracture of cross-linked UHMWPE acetabular liners10.1016/j.biomaterials.2009.07.013 ↗
17. Normal hip joint contact pressure distribution in single-leg standing—effect of gender and anatomic parameters10.1016/S0021-9290(01)00041-0 ↗
18. Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene10.1016/j.biomaterials.2005.09.010 ↗
19. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report10.2106/00004623-200404000-00025 ↗
20. Holzwarth, U., Cotogno, G., 2012. Total hip Arthroplasty: State of the Art, Challenges and Prospects. JRC Scientific and Policy Reports [online]. Available from 〈https://ec.europa.eu/jrc/sites/default/files/lbna25378enn.pdf〉
21. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses10.1002/jbm.820170510 ↗
22. ISO 5834-4:2005, Implants for surgery – ultra-high-molecular-weight polyethylene-Part 4: Oxidation index measurement method.
23. Gender differences in joint biomechanics during walking normative study in young adults10.1097/00002060-199801000-00002 ↗
24. No difference in gender-specific hip replacement outcomes10.1007/s11999-008-0466-2 ↗
25. Prevalence of primary and revision total hip and knee arthroplasty in the Unites States from 1990 through 2002
26. Kurtz, S. (Ed) 2009. The UHMWPE Handbook. Ultra-High Molecular Weight Polyethylene in Total Joint Replacement. 2nd ed. Elsevier, Oxford.
27. Patient perceived outcomes after primary hip arthroplasty: does gender matter?10.1007/s11999-010-1503-5 ↗
28. The operation of the century: total hip replacement10.1016/S0140-6736(07)60457-7 ↗
29. Early failures of total hip replacement: effect of surgeon volume10.1002/art.20148 ↗
30. The Swedish total hip replacement register
31. PE-UHMW in hip implants: properties of conventional and crosslinked prosthetic components10.1002/adem.200900050 ↗
32. Fractography evolution in accelerated aging of UHMWPE after gamma irradiation in air10.1016/S0142-9612(03)00464-2 ↗
33. The female knee: anatomic variations and the female-specific total knee design10.1007/s11999-008-0536-5 ↗
34. Muratoglu · 2009
35. Age and waiting time as predictors of outcome after total hip replacement for osteoarthritis10.1093/rheumatology/41.11.1261 ↗
36. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
37. Radiation cross-linking in ultra-high molecular weight polyethylene for orthopaedic applications10.1016/j.nimb.2007.08.022 ↗
38. Bone mass and structure at the hip in men and women over the age of 60 years10.1007/s001980050059 ↗
39. The Swedish Knee Arthroplasty Register 1975–1997: an update with special emphasis on 41223 knees operated on in 1988–199710.1080/000164701753532853 ↗
40. Does sex matter in musculoskeletal health? The influence of sex and gender on musculoskeletal health
41. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty10.2106/00004623-200710000-00016 ↗
42. The influence of patient factors on patient-reported outcomes of orthopedic surgery involving implantable devices: a systemeatic review10.1016/j.semarthrit.2014.08.002 ↗
43. Gender differences in hip anatomy: possible implications for injury tolerance in frontal collisions
44. Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living10.1016/j.jbiomech.2005.06.026 ↗