journal article·2019-10Open access

Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions

Mazen Al-Hajjar, Laurent Gremillard, Sabine Begand, Thomas Oberbach, Karen Hans, Daniel Delfosse, Jérôme Chevalier, Louise M. Jennings

Abstract

Ceramic-on-ceramic bearings in total hip replacement have shown the potential to provide low wear solutions in hip replacement. Assessing the tribological performance of these materials is important to predict their long-term performance in patients. In this study, a methodology was devised to assess the tribological in vitro behaviour of composite ceramics under combined adverse edge loading conditions and accelerated ageing. Two commercial ceramic composites were considered, namely Alumina-Toughened Zirconia (ATZ, ceramys®) and Zirconia-Toughened Alumina (ZTA, symarec®). The bearing couples were studied using the Leeds Mark II hip joint simulator for a total of eight million cycles, the first two million under normal gait (no edge loading) and the following six million cycles with the addition of edge loading conditions driven by medial-lateral separation. The bearing couples underwent hydrothermal ageing using an accelerated protocol in autoclave every million cycles. The influence of edge loading combined with ageing was significant for ATZ bearings, resulting in a slower overall ageing kinetics over the wear stripe than on the control heads. During the autoclave ageing steps, the monoclinic fraction increased more over the wear stripe area than over the unworn area. Both results thus indicated that the monoclinic phase was removed during shocks induced by edge loading. The wear performance of the two materials were similar exhibiting relatively low wear rates and low level of microstructural damage for these clinically relevant adverse conditions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Al-Hajjar · 2019
2. Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX(R) delta ceramic-on-ceramic total hip replacement10.1002/jbm.b.31708 ↗
3. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions10.1177/0954411912474613 ↗
4. Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions10.1002/jbm.b.32965 ↗
5. Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions10.1002/jbm.b.33671 ↗
6. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates10.1243/0954411991535068 ↗
7. Ceramic-on-ceramic bearings in total hip arthroplasty10.1097/00003086-200212000-00019 ↗
8. In vivo assessment of total hip femoral head separation from the acetabular cup during 4 common daily activities10.3928/01477447-20110427-06 ↗
9. Experimental study of aluminium in surgery of hip
10. Low-temperature aging of Y-TZP ceramics10.1111/j.1151-2916.1999.tb02055.x ↗
11. On the kinetics and impact of tetragonal to monoclinic transformation in an alumina/zirconia composite for arthroplasty applications10.1016/j.biomaterials.2009.06.022 ↗
12. Measurement of the crystallographically transformed zone produced by fracture in ceramics containing tetragonal zirconia10.1111/j.1151-2916.1982.tb10445.x ↗
13. Ceramic bearings for total hip arthroplasty have high survivorship at 10 years10.1007/s11999-011-2076-7 ↗
14. Dennis DA, Komistek RD, Northcut EJ, Ochoa JA, Hammill C. In Vivo Determination of Hip Joint Separation in Subjects Having Either a Metal on Metal or Metal on Polyethylene Total Hip Arthroplasty. 47th Annual Meeting Orthopaedic Research Society. San Francisco2001.
15. Comparative ageing behaviour of commercial, unworn and worn 3Y-TZP and zirconia-toughened alumina hip joint heads10.1016/j.jeurceramsoc.2012.01.003 ↗
16. Phase Analysis in zirconia systems10.1111/j.1151-2916.1972.tb11290.x ↗
17. Combining ageing and wear to assess the durability of zirconia-based ceramic heads for total hip arthroplasty10.1016/j.actbio.2013.03.030 ↗
18. Sub-surface assessment of hydrothermal ageing in zirconia-containing femoral heads for hip joint applications10.1016/j.actbio.2017.12.021 ↗
19. Phase change and mechanical properties of ZrO2-Y2O3 solid electrolyte after ageing10.1016/0167-2738(81)90138-7 ↗
20. Incidence of modern alumina ceramic and alumina matrix composite femoral head failures in nearly 6 million hip implants10.1016/j.arth.2016.08.011 ↗
21. High cup angle and microseparation increase the wear of hip surface replacements10.1007/s11999-009-0830-x ↗
22. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns10.1054/arth.2000.8100 ↗
23. A testing protocol combining shocks, hydrothermal ageing and friction, applied to Zirconia Toughened Alumina (ZTA) hip implants10.1016/j.jmbbm.2016.09.019 ↗
24. Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing results after a minimum of twenty years of follow-up10.2106/JBJS.H.01829 ↗
25. Ceramic on ceramic arthroplasty of the hip10.1302/0301-620X.98B1.36347 ↗
26. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation10.1002/jbm.b.10035 ↗
27. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation10.1016/S0883-5403(03)00204-3 ↗
28. Calibration curve for quantitative analysis of the monoclinic-tetragonal ZrO2 system by X-ray diffraction10.1111/j.1151-2916.1984.tb19614.x ↗
29. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position10.2106/JBJS.H.00485 ↗
30. Atraumatic fracture of the BIOLOX delta ceramic liner in well-fixed total hip implants10.3928/01477447-20180815-07 ↗