journal article·2011-04Open access

Multi-axial loading micromechanics of the cement–bone interface in postmortem retrievals and lab-prepared specimens

Mark A. Miller, Amos Race, Daan Waanders, Richard Cleary, Dennis Janssen, Nico Verdonschot, Kenneth A. Mann

Abstract

Maintaining adequate fixation between cement and bone is important for successful long term survival of cemented total joint replacements. Mixed-mode loading conditions (combination of tension/compression and shear) are present during in vivo loading, but the micromotion response of the interface to these conditions is not fully understood. Non-destructive, multi-axial loading experiments were conducted on laboratory prepared (n=6) and postmortem (n=6) human cement-bone interfaces. Specimens were mounted in custom loading discs and loaded at 0°, 30°, 60°, and 90° relative to the interface plane where 0° represents normal loading to the interface, and 90° represents shear loading along the longitudinal axis of the femur. Axial compliance did not depend on loading angle for laboratory prepared (p=0.96) or postmortem specimens (p=0.62). The cement-bone interface was more compliant under tensile than compressive loading at the 0° loading angle only (p=0.024). The coupled transverse to axial compliance ratio, which is a measure of the coupled motion, was small for laboratory prepared (0.115 ± 0.115) and postmortem specimens (0.142 ± 0.101). There was a moderately strong inverse relationship between interface compliance and contact index (r(2)=0.65). From a computational modeling perspective, the results of the current study support the concept that the cement-bone interface could be numerically implemented as a compliant layer with the same initial stiffness in tension and shear directions. The magnitude of the compliance could be modified to simulate immediate post-operative conditions (using laboratory prepared data set) or long-term remodeling (using postmortem data set).
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Rock Mechanics and Modeling · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Fatigue of the cement/bone interface: the surface texture of bone and loosening10.1002/jbm.b.30364 ↗
2. The condition of the cement mantle in femoral hip prosthesis implantations—a post mortem retrieval study10.1177/112070000901900202 ↗
3. Global mechanical consequences of reduced cement/bone coupling rigidity in proximal femoral arthroplasty: a three-dimensional finite element analysis10.1016/0021-9290(88)90005-X ↗
4. Mechanical influences on tissue differentiation at bone-cement interfaces10.1016/S0883-5403(05)80154-8 ↗
5. The cement–bone interface: is it susceptible to damage adaptive remodeling?
6. Experimental micromechanics of the cement–bone interface10.1002/jor.20575 ↗
7. Shear fatigue micromechanics of the cement–bone interface: an in vitro study using digital image correlation techniques10.1002/jor.20777 ↗
8. Mechanical strength of the cement–bone interface is greater in shear than in tension10.1016/S0021-9290(99)00107-4 ↗
9. Micro-mechanics of post-mortem retrieved cement–bone interfaces10.1002/jor.20893 ↗
10. A coupled viscoplastic rate-dependent damage model for the simulation of fatigue of cement–bone interfaces10.1016/j.ijplas.2007.02.005 ↗
11. Modelling the mixed-mode failure of cement–bone interfaces10.1016/j.engfracmech.2006.01.005 ↗
12. Does increased bone–cement interface strength have negative consequences for bulk cement integrity? A finite element study10.1007/s10439-008-9616-7 ↗
13. Comparative finite element analysis of the debonding process in different concepts of cemented hip implants10.1007/s10439-010-9996-3 ↗
14. Determination of interfacial fracture toughness of bone–cement interface using sandwich Brazilian disks10.1016/j.engfracmech.2006.02.014 ↗
15. The mechanical effects of different levels of cement penetration at the cement–bone interface10.1016/j.jbiomech.2009.11.033 ↗
16. Modeling the fibrous tissue layer in cemented hip replacements: experimental and finite element methods10.1016/S0021-9290(03)00258-6 ↗
17. Bone–cement interfacial behaviour under mixed mode loading conditions10.1016/j.jmbbm.2010.03.001 ↗