Mechanical and surface chemical analysis of retrieved breast implants from a single centre
Source abstract
Abstract
Introduction Breast implants are associated with complications such as capsular contracture, implant rupture and leakage often necessitating further corrective surgery. Re-operation rates have been reported to occur in up to 15.4% of primary augmentation patients and up to 27% in primary reconstructions patients within the first three years (Cunningham, 2007). The aim of this study was to examine the mechanical and surface chemical properties as well as the fibroblast response of retrieved breast implants in our unit to determine the in vivo changes which occur over time. Methods Ethical approval was obtained. 47 implants were retrieved. Implantation time ranged from 1 month to 388 months (Mean 106.1 months). Tensile strength, elongation, Young's modulus and tear strength properties were measured using Instron 5565 tensiometer on anterior and posterior aspects of the implant. Attenuated total reflectance-fourier transform infra-red spectroscopy (ATR-FTIR), wettability and scanning electron microscopy (SEM) analysis was performed on the shell surfaces. Bicinchoninic acid assay was performed to determine shell protein content. The fibroblast response was determined by seeding HDFa cells on the retrieved implants and cell metabolism measured using Alamar Blue™ assay. Results Mechanical properties fall with increasing duration of implantation. There were no significant changes in ATR-FTIR spectra between ruptured and intact implants nor significant changes in wettability in implants grouped into 5 year categories. SEM imaging reveals surface degradation changes with increasing duration of implantation. Conclusions With increasing duration of implantation, mechanical properties of the breast implants fall. However this was not associated with surface chemical changes as determined by ATR-FTIR and wettability nor protein content of the shells. Thus the reduction in mechanical properties is associated with breast implant failure but further research is required to elucidate the mechanisms.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Breast Implant and Reconstruction · Bone Tissue Engineering Materials · Corneal surgery and disorders
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (24)
Show source-provided references
1. Lipid infiltration as a possible biologic cause of silicone gel breast implant aging10.1097/00006534-199801000-00011 ↗
2. Chemical and structural characterization of several mid-term explanted breast prostheses10.3390/ma9080678 ↗
3. Aging of retrieved gel breast implants: a comparison between two product generations10.1016/j.jmbbm.2015.02.008 ↗
4. Brandon, H.J., Wolf, C.J., 2012. Biomaterials in Plastic Surgery. doi:10.1533/9780857096418.154.10.1533/9780857096418.154 ↗
5. Variability in the properties of silicone gel breast implants10.1097/00006534-200109010-00008 ↗
6. The mentor core study on silicone memory gel breast implants10.1097/01.prs.0000286574.88752.04 ↗
7. Mechanical analysis of explanted silicone breast implants10.1097/00006534-199608000-00008 ↗
8. Mechanical analysis of explanted silicone breast implants10.1097/00006534-199608000-00008 ↗
9. Silicone gel breast implant failure: evaluation of properties of shells and gels for explanted prostheses and meta-analysis of literature rupture data10.1097/00000637-200209000-00001 ↗
10. Silicone gel breast implant failure: evaluation of properties of shells and gels for explanted prostheses and meta-analysis of literature rupture data10.1097/00000637-200209000-00001 ↗
11. A systematic review of complications of implant-based breast reconstruction with prereconstruction and postreconstruction radiotherapy10.1245/s10434-013-3284-z ↗
12. Failure of silicone gel breast implants: is the mechanical weakening due to shell swelling a significant cause of prostheses rupture?10.1016/j.jmbbm.2011.06.019 ↗
13. Textured and smooth breast implants: is there a difference in the chemical structure of silicone?10.1097/SAP.0b013e3181953791 ↗
14. Strength of silicone breast implants10.1097/00006534-199605000-00017 ↗
15. Controlling cellular activity by manipulating silicone surface roughness10.1016/j.colsurfb.2010.03.006 ↗
16. An experimental analysis of shell failure in breast implants10.1016/j.jmbbm.2017.04.005 ↗
17. Mechanical performance of poly implant prosthesis (PIP) breast implants: a comparative study10.1007/s00266-017-0776-4 ↗
18. The effect of post-mastectomy radiation therapy on breast implants: unveiling biomaterial alterations with potential implications on capsular contracture10.1016/j.msec.2015.07.015 ↗
19. Rupture of poly implant prothèse silicone breast implants: an implant retrieval study10.1097/PRS.0b013e3182818a00 ↗
20. Characterisation of breast implant surfaces and correlation with fibroblast adhesion10.1016/j.jmbbm.2013.02.005 ↗
21. Adhesion of mouse fibroblasts on hexamethyldisiloxane surfaces with wide range of wettability10.1002/jbm.b.30638 ↗
22. Effect of surgical insertion on the local shell properties of SILASTIC II silicone gel breast implants10.1163/156856200743544 ↗
23. Capsular contracture in subglandular breast augmentation with textured versus smooth breast implants: a systematic review10.1097/01.prs.0000237013.50283.d2 ↗
24. Surface and mechanical analysis of explanted poly implant prosthèse silicone breast implants10.1002/bjs.9094 ↗