Characterization of perfused and sectioned liver tissue in a full indentation cycle using a visco-hyperelastic model
Source abstract
Abstract
Realistic modeling of biologic material is required for optimizing fidelity in computer-aided surgical training and assistance systems. The modeling of liver tissue has remained challenging due to its nonlinear viscoelastic properties and high hysteresis of the stress-strain relation. While prior studies have described the behavior of liver tissue during the loading status (in elongation, compression, or indentation tests) or unloading status (in stress relaxation or creep tests), a hysteresis curve with both loading and unloading processes was incompletely defined. We seek to use a single material model to characterize the mechanical properties of liver tissue in a full indentation cycle ex vivo perfused and then sectioned. Based on measurements taken from ex-vivo perfused porcine livers, we converted force-displacement curves to stress-strain curves and developed a visco-hyperelastic constitutive model to characterize the liver's mechanical behavior at different locations under various rates of indentation (1, 2, 5, 10, and 20 mm/s). The proposed model is a mixed visco-hyperelastic model with up to 6 coefficients. The normalized root mean square standard deviations of fitted curves are less than 5% and 10% in low (<0.05) and high strain (>0.3) conditions respectively.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Elasticity and Material Modeling · Automotive and Human Injury Biomechanics · Orthopaedic implants and arthroplasty
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (67)
Show source-provided references
1. Visual-perceptual mismatch in robotic surgery10.1007/s00464-016-5358-z ↗
2. Measurement and characterization of soft tissue behavior with surface deformation and force response under large deformations10.1016/j.media.2009.10.006 ↗
3. Rupture probability of porcine liver under planar and point loading10.1088/2057-1976/2/5/055018 ↗
4. Effect of solution and post-mortem time on mechanical and histological properties of liver during cold preservation
5. Effect of normal compression on the shear modulus of soft tissue in rheological measurements10.1016/j.jmbbm.2015.05.011 ↗
6. A rheological network model for the continuum anisotropic and viscoelastic behavior of soft tissue10.1007/s10237-004-0049-4 ↗
7. Boyer · 2011
8. In-vivo and in-situ compressive properties of porcine abdominal soft tissues
9. Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure10.1016/j.jbiomech.2010.03.038 ↗
10. In vivo liver tissue mechanical properties by transient elastography: comparison with dynamic mechanical analysis
11. Computational modeling in liver surgery10.3389/fphys.2017.00906 ↗
12. Combined compression and elongation experiments and non-linear modelling of liver tissue for surgical simulation10.1007/BF02345212 ↗
13. Transversely isotropic properties of porcine liver tissue: experiments and constitutive modelling10.1007/s11517-006-0137-y ↗
14. The normal adult human liver biopsy: a quantitative reference standard10.1002/hep.510280206 ↗
15. Mathematical modelling for keyhole surgery simulations: a biomechanical model for spleen tissue10.1093/imamat/67.1.41 ↗
16. Experimental validation of a flat punch indentation methodology calibrated against unconfined compression tests for determination of soft tissue biomechanics10.1016/j.jmbbm.2016.02.019 ↗
17. Needle insertion modeling and simulation10.1109/TRA.2003.817044 ↗
18. Scale-dependent mechanical properties of native and decellularized liver tissue10.1007/s10237-012-0426-3 ↗
19. Liver tissue characterization from uniaxial stress-strain data using probabilistic and inverse finite element methods10.1016/j.jmbbm.2013.01.008 ↗
20. Fung · 2013
21. Constitutive modeling of liver tissue: experiment and theory10.1007/s10439-009-9812-0 ↗
22. Linear viscoelastic behavior of subcutaneous adipose tissue
23. Hollenstein, M., Nava, A., Valtorta, D., Snedeker, J.G., Mazza, E., 2006. Mechanical characterization of the liver capsule and parenchyma. In: Proceedings of the International Symposium on Biomedical Simulation, Springer, pp. 150–158.10.1007/11790273_17 ↗
24. A layer-specific three-dimensional model for the simulation of balloon angioplasty using magnetic resonance imaging and mechanical testing10.1114/1.1492812 ↗
25. The influence of test conditions on characterization of the mechanical properties of brain tissue10.1115/1.2907746 ↗
26. Hu, T., Desai, J.P., Castellanos, A., Lau, A.C., 2006. Modeling in vivo soft tissue probing. In: Proceedings of the First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006, BioRob 2006, IEEE, pp. 537–542.
27. Constitutive modeling of porcine liver in indentation using 3d ultrasound imaging10.1016/j.jmbbm.2008.08.006 ↗
28. Diffusion of robotic-assisted laparoscopic technology across specialties: a national study from 2008 to 201310.1007/s00464-017-5822-4 ↗
29. Kerdok, A.E., Howe, R.D., 2005. A physical basis for a two time constant constitutive model for liver. In: Proceedings of the ASME Summer Bioengineering Conference.
30. Effects of perfusion on the viscoelastic characteristics of liver10.1016/j.jbiomech.2005.07.005 ↗
31. Kerdok · 2006
32. Kim, J., Srinivasan, M.A., 2005. Characterization of viscoelastic soft tissue properties from in vivo animal experiments and inverse fe parameter estimation. In: Proceedings of the International Conference on Medical Image Computing and Computer-Assisted Intervention, Springer, pp. 599–606.10.1007/11566489_74 ↗
33. Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue10.1016/j.jbiomech.2009.03.002 ↗
34. Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography
35. Development of in vivo constitutive models for liver: application to surgical simulation10.1007/s10439-010-0227-8 ↗
36. Contemporary open and robotic radical prostatectomy practice patterns among urologists in the united states10.1016/j.juro.2012.01.061 ↗
37. Fast porous visco-hyperelastic soft tissue model for surgery simulation: application to liver surgery10.1016/j.pbiomolbio.2010.09.005 ↗
38. Transatlantic robot-assisted telesurgery10.1038/35096636 ↗
39. Viscoelastic characterisation of pig liver in unconfined compression10.1016/j.jbiomech.2014.05.017 ↗
40. The mechanical response of human liver and its relation to histology: an in vivo study10.1016/j.media.2007.06.010 ↗
41. Characterizing viscoelastic mechanical properties of highly compliant polymers and biological tissues using impact indentation10.1016/j.actbio.2018.02.017 ↗
42. Biomechanics of soft tissues
43. A theory of large elastic deformation10.1063/1.1712836 ↗
44. Porohyperviscoelastic model simultaneously predicts parenchymal fluid pressure and reaction force in perfused liver10.1115/1.4007175 ↗
45. In vivo mechanical characterization of human liver10.1016/j.media.2007.10.001 ↗
46. Large deformation isotropic elasticity-on the correlation of theory and experiment for incompressible rubberlike solids10.1098/rspa.1972.0026 ↗
47. Ogden · 1997
48. Ogden, R.W., 2005. Mechanics of rubberlike solids. In: Proceedings of the Mechanics of the 21st Century, Springer, pp. 263–274.10.1007/1-4020-3559-4_17 ↗
49. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments10.1557/JMR.1992.1564 ↗
50. Ottensmeyer · 2004 · 9
51. Large elastic deformations of isotropic materials. iv. further developments of the general theory10.1098/rsta.1948.0024 ↗
52. Sagar, M.A., Bullivant, D., Mallinson, G.D., Hunter, P.J., 1994. A virtual environment and model of the eye for surgical simulation. In: Proceedings of the 21st Annual Conference on Computer Graphics and Interactive Techniques, ACM, pp. 205–212.10.1145/192161.192200 ↗
53. Sakuma, I., Nishimura, Y., Chui, C.K., Kobayashi, E., Inada, H., Chen, X., Hisada, T., 2003. In vitro measurement of mechanical properties of liver tissue under compression and elongation using a new test piece holding method with surgical glue. In: Proceedings of the Surgery Simulation and Soft Tissue Modeling, Springer, pp. 284–292.10.1007/3-540-45015-7_27 ↗
54. A robotic indenter for minimally invasive measurement and characterization of soft tissue response10.1016/j.media.2007.04.001 ↗
55. Modelling liver tissue properties using a non-linear visco-elastic model for surgery simulation10.1016/j.media.2004.11.002 ↗
56. Analysis of vasculature for liver surgical planning10.1109/TMI.2002.801166 ↗
57. The relation between load and penetration in the axisymmetric boussinesq problem for a punch of arbitrary profile10.1016/0020-7225(65)90019-4 ↗
58. In vivo mechanical behavior of intra-abdominal organs10.1109/TBME.2006.879474 ↗
59. Strain rate viscoelastic analysis of soft and highly hydrated biomaterials10.1002/jbm.a.34914 ↗
60. Experimental in vitro mechanical characterization of porcine glisson's capsule and hepatic veins10.1016/j.jbiomech.2011.03.029 ↗
61. Experimental mechanical characterization of abdominal organs: liver, kidney & spleen10.1016/j.jmbbm.2012.07.010 ↗
62. Dynamic measurement of soft tissue viscoelastic properties with a torsional resonator device10.1016/j.media.2005.05.002 ↗
63. The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review10.1007/s00464-008-0298-x ↗
64. Vemaganti, K., Roan, E., 2007. Viscohyperelastic material modeling of liver tissue. In: Proceedings of the ASME 2007 Summer Bioengineering Conference, American Society of Mechanical Engineers, pp. 433–434.10.1115/SBC2007-176728 ↗
65. Biomechanics and functional adaption of tendons and joint ligaments
66. Functional properties of collagenous tissues10.1016/B978-0-12-363706-2.50010-6 ↗
67. Estimating the effective young's modulus of soft tissues from indentation tests–nonlinear finite element analysis of effects of friction and large deformation10.1016/S1350-4533(97)00017-9 ↗