journal article·2015-08Open access

A new design concept for knitted external vein-graft support mesh

Charanpreet Singh, Xungai Wang

Abstract

Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cardiac Structural Anomalies and Repair · Cardiac Valve Diseases and Treatments · Coronary Interventions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Effect of compliance mismatch on vascular graft patency10.1016/0741-5214(87)90148-0 ↗
2. Expandable external support device to improve Saphenous vein graft patency after CABG10.1186/1749-8090-8-122 ↗
3. Vein compliance: a preoperative indicator of vein morphology and veins at risk of vascular graft stenosis10.1002/bjs.1800791011 ↗
4. Pathophysiology of vein graft failure: a review10.1016/S1078-5884(05)80218-7 ↗
5. Inhibition of neointimal formation and hyperplasia in vein grafts by external stent/sheath10.1177/1358863X10366479 ↗
6. Mechanical factors predisposing to intimal hyperplasia and medial thickening in autogenous vein grafts
7. Transient elastic support for vein grafts using a constricting microfibrillar polymer wrap10.1016/j.biomaterials.2008.04.009 ↗
8. Implantation of the eSVS mesh
9. Use of the eSVS mesh: external vein support does not negatively impact early graft patency
10. Saphenous vein graft failure after coronary artery bypass surgery: pathophysiology, management, and future directions10.1097/SLA.0b013e318288c38d ↗
11. Mechanical properties of synthetic arterial grafts10.1016/0021-9290(79)90039-3 ↗
12. A bioabsorbable (polyglactin), nonrestrictive, external sheath inhibits porcine saphenous vein graft thickening10.1016/j.jtcvs.2003.09.054 ↗
13. Biomechanics of coronary artery and bypass graft disease: potential new approaches10.1016/j.athoracsur.2008.07.023 ↗
14. The effect of wall mechanical properties on patency of arterial grafts
15. The effect of rigid external support on vein graft adaptation to the arterial circulation10.1016/0741-5214(89)90047-5 ↗
16. A new outside stent – does it prevent vein graft intimal proliferation?10.1016/S1010-7940(02)00587-0 ↗
17. Changes in the organization of the smooth muscle cells in rat vein grafts10.1114/1.52 ↗
18. The use of external mesh reinforcement to reduce intimal hyperplasia and preserve the structure of human saphenous veins10.1016/j.biomaterials.2013.12.041 ↗
19. 2011 ACCF/AHA guideline for coronary artery bypass graft surgery: a report of the american college of cardiology foundation/American heart association task force on practice guidelines
20. Protective constriction of coronary vein grafts with knitted nitinol10.1093/ejcts/ezs670 ↗
21. A randomized trial of an external Dacron sheath for the prevention of vein graft disease: the extent study10.1016/j.jtcvs.2007.01.092 ↗
22. Pressure applied during surgery alters the biomechanical properties of human saphenous vein graft10.1007/s00380-012-0245-6 ↗
23. New stent for support of veins in arterial grafts10.1001/archsurg.1963.01310160158031 ↗
24. Molecular and cellular changes in vein grafts: influence of pulsatile stretch10.1097/00001573-199811000-00011 ↗
25. Highly flexible nitinol mesh to encase aortocoronary saphenous vein grafts: first clinical experiences and angiographic results nine months postoperatively10.1510/icvts.2010.265116 ↗
26. A biomimetic approach for designing stent-graft structures: caterpillar cuticle as design model10.1016/j.jmbbm.2013.10.014 ↗
27. Pressure-diameter relationship in the human greater saphenous vein10.1016/S0003-4975(03)00896-8 ↗
28. Biologic fate of autogenous vein implants as arterial substitutes: clinical, angiographic and histopathologic observations in femoro-popliteal operations for atherosclerosis10.1097/00000658-197309000-00002 ↗
29. Improving the patency of vascular bypass grafts: the role of suture materials and surgical techniques on reducing anastomotic compliance mismatch10.1053/ejvs.2002.1810 ↗
30. Compliance and formation of distal anastomotic intimal hyperplasia in Dacron mesh tube constricted veins used as arterial bypass grafts10.1097/00002480-199407000-00007 ↗
31. A computational study of knitted Nitinol meshes for their prospective use as external vein reinforcement10.1016/j.jbiomech.2008.01.016 ↗
32. Long-term reduction of medial and intimal thickening in porcine saphenous vein grafts with a polyglactin biodegradable external sheath10.1016/j.jvs.2004.08.047 ↗
33. External supports and the prevention of neointima formation in vein grafts10.1053/ejvs.2002.1676 ↗
34. Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis10.1016/0021-9290(95)00028-3 ↗
35. Viscoelastic behavior of fibers during woven fabric bagging10.1177/004051750007000901 ↗
36. Constrictive external nitinol meshes inhibit vein graft intimal hyperplasia in nonhuman primates10.1016/j.jtcvs.2008.02.068 ↗
37. Knitted nitinol represents a new generation of constrictive external vein graft meshes10.1016/j.jvs.2011.05.023 ↗
38. Utilization of shape memory in external vein-graft meshes allows extreme diameter constriction for suppressing intimal hyperplasia: a non-human primate study10.1016/j.jvs.2009.01.068 ↗
39. The orthotropic viscoelastic behavior of aortic elastin10.1007/s10237-010-0260-4 ↗