journal article·2017-05

Fatigue life of bovine meniscus under longitudinal and transverse tensile loading

Jaremy J. Creechley, Madison E. Krentz, Trevor J. Lujan

Publisher page

Abstract

The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loads either longitudinal or transverse to the principal fiber direction. Fatigue experiments consisted of cyclic loads to 60%, 70%, 80% or 90% of the predicted ultimate tensile strength until failure occurred or 20,000 cycles was reached. The fatigue data in each group was fit with a Weibull distribution to generate plots of stress level vs. cycles to failure (S-N curve). Results showed that loading transverse to the principal fiber direction gave a two-fold increase in failure strain, a three-fold increase in creep, and a nearly four-fold increase in cycles to failure (not significant), compared to loading longitudinal to the principal fiber direction. The S-N curves had strong negative correlations between the stress level and the mean cycles to failure for both loading directions, where the slope of the transverse S-N curve was 11% less than the longitudinal S-N curve (longitudinal: S=108-5.9ln(N); transverse: S=112-5.2ln(N)). Collectively, these results suggest that the non-fibrillar matrix is more resistant to fatigue failure than the collagen fibers. Results from this study are relevant to understanding the etiology of atraumatic radial and horizontal meniscal tears, and can be utilized by research groups that are working to develop meniscus implants with fatigue properties that mimic healthy tissue.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Sports injuries and prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. (ASTM) · 2002
2. (ASTM) · 2015
3. Regional and fiber orientation dependent shear properties and anisotropy of bovine meniscus10.1016/j.jmbbm.2011.06.022 ↗
4. Tendon fatigue in response to mechanical loading
5. Tie-fibre structure and organization in the knee menisci10.1111/joa.12170 ↗
6. Athanasiou KA, Sanchez-Adams J., 2009. Engineering the Knee Meniscus: Morgan & Claypool.10.1007/978-3-031-02576-1 ↗
7. Review of meniscal injury and associated sports10.1177/036354658501300101 ↗
8. Sports injury, occupational physical activity, joint laxity, and meniscal damage
9. Fatigue failure of aircraft components10.1016/j.engfailanal.2007.10.001 ↗
10. Viscoelastic properties of the human medial collateral ligament under longitudinal, transverse and shear loading10.1016/j.orthres.2004.06.002 ↗
11. Is there an association between articular cartilage changes and degenerative meniscus tears?10.1016/j.arthro.2005.08.031 ↗
12. Comparison of nonlinear mechanical properties of bovine articular cartilage and meniscus10.1016/j.jbiomech.2013.09.015 ↗
13. "Fatigue meniscal tears": a description of the lesion and the results of arthroscopic partial meniscectomy10.1007/s00264-015-3010-5 ↗
14. Subrupture tendon fatigue damage10.1002/jor.20722 ↗
15. Changes in articular cartilage after meniscectomy and meniscus replacement using a biodegradable porous polymer implant10.1007/s00167-010-1244-8 ↗
16. Quantitative relationships between microdamage and cancellous bone strength and stiffness10.1016/j.bone.2014.05.023 ↗
17. Direct measurement of hoop strains in the intact and torn human medial meniscus10.1016/0268-0033(96)00003-4 ↗
18. Hydrogel meniscal replacement in the sheep knee: preliminary evaluation of chondroprotective effects10.1177/0363546506292848 ↗
19. Increase in outpatient knee arthroscopy in the United States: a comparison of National Surveys of Ambulatory Surgery, 1996 and 200610.2106/JBJS.I.01618 ↗
20. Analysis of 3D Strain in the Human Medial Meniscus
21. MR accuracy and arthroscopic incidence of meniscal radial tears10.1007/s00256-002-0579-8 ↗
22. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration10.1016/j.biomaterials.2011.06.037 ↗
23. Tendon material properties vary and are interdependent among turkey hindlimb muscles
24. The consequences of meniscectomy10.1302/0301-620X.88B12.18140 ↗
25. The ultrastructure and biochemistry of meniscal cartilage10.1097/00003086-199003000-00003 ↗
26. The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment10.1046/j.1469-7580.1998.19320161.x ↗
27. Prospective evaluation of 1485 meniscal tear patterns in patients with stable knees10.1177/0095399703258743 ↗
28. Compressive cyclic ratcheting and fatigue of synthetic, soft biomedical polymers in solution10.1016/j.jmbbm.2015.09.034 ↗
29. Python for scientific computing10.1109/MCSE.2007.58 ↗
30. Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and Failure10.1115/1.4032354 ↗
31. Material properties of the normal medial bovine meniscus10.1002/jor.1100070602 ↗
32. Mechanisms of fatigue-crack propagation in ductile and brittle solids10.1023/A:1018655917051 ↗
33. The association of meniscal damage with joint effusion in persons without radiographic osteoarthritis: the Framingham and MOST osteoarthritis studies10.1016/j.joca.2008.09.013 ↗
34. In vitro fatigue of human tendons10.1016/S0021-9290(97)00033-X ↗
35. Fatigue damage of human tendons10.1016/S0021-9290(01)00177-4 ↗
36. Viscoelastic properties of a synthetic meniscus implant10.1016/j.jmbbm.2013.08.021 ↗
37. Intraspecies and interspecies comparison of the compressive properties of the medial meniscus10.1114/B:ABME.0000049040.70767.5c ↗
38. Microdamage and mechanical behaviour: predicting failure and remodelling in compact bone10.1046/j.1469-7580.2003.00194.x ↗
39. Taylor TL, Frankovich R, Rumball J., 2009. Bilateral atraumatic medial meniscal tears in a 17-year-old rower. BMJ Case Reports 2009.10.1136/bcr.11.2008.1258 ↗
40. Meniscal tear characteristics in young athletes with a stable knee: arthroscopic evaluation10.1177/0363546506287939 ↗
41. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons10.1016/j.actbio.2016.06.012 ↗
42. Tensile stress-strain characteristics of the human meniscal material10.1016/0021-9290(94)00081-E ↗
43. Review of the clinical results of arthroscopic meniscal repair10.1016/S0968-0160(01)00061-8 ↗
44. Altered regional loading patterns on articular cartilage following meniscectomy are not fully restored by autograft meniscal transplantation10.1016/j.joca.2014.12.003 ↗
45. A comparative study of meniscectomy and nonoperative treatment for degenerative horizontal tears of the medial meniscus10.1177/0363546513488518 ↗
46. Changes in the stiffness, strength, and toughness of human cortical bone with age10.1016/S8756-3282(97)00228-7 ↗