A novel approach to determine primary stability of acetabular press-fit cups
Source abstract
Abstract
Today hip cups are used in a large variety of design variants and in increasing numbers of units. Their development is steadily progressing. In addition to conventional manufacturing methods for hip cups, additive methods, in particular, play an increasingly important role as development progresses. The present paper describes a modified cup model developed based on a commercially available press-fit cup (Allofit 54/JJ). The press-fit cup was designed in two variants and manufactured using selective laser melting (SLM). Variant 1 (Ti) was modeled on the Allofit cup using an adapted process technology. Variant 2 (Ti-S) was provided with a porous load bearing structure on its surface. In addition to the typical (complete) geometry, both variants were also manufactured and tested in a reduced shape where only the press-fit area was formed. To assess the primary stability of the press-fit cups in the artificial bone cavity, pull-out and lever-out tests were carried out. Exact fit conditions and two-millimeter press-fit were investigated. The closed-cell PU foam used as an artificial bone cavity was mechanically characterized to exclude any influence on the results of the investigation. The pull-out forces of the Ti-variant (complete-526 N, reduced-468 N) and the Ti-S variant (complete-548 N, reduced-526 N) as well as the lever-out moments of the Ti-variant (complete-10 Nm, reduced-9.8 Nm) and the Ti-S variant (complete-9 Nm, reduced-7.9 N) show no significant differences in the results between complete and reduced cups. The results show that the use of reduced cups in a press-fit design is possible within the scope of development work.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Dental materials and restorations · Additive Manufacturing Materials and Processes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Stability of press-fit acetabular cups10.1016/0883-5403(92)90052-R ↗
2. Mechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells10.1016/j.jmbbm.2014.02.003 ↗
3. Factors influencing initial cup stability in total hip arthroplasty10.1016/j.clinbiomech.2014.09.006 ↗
4. Initial stability of a cementless acetabular cup design: experimental investigation on the effect of adding fins to the rim of the cup10.1046/j.1525-1594.2001.025008664.x ↗
5. Our experience with the use of TT (trabecular titanium) in hip arthroplasty surgery
6. Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium10.1016/j.arth.2010.12.007 ↗
7. Revision total hip arthroplasty using a tapered, Press-fit cementless revision stem in elderly patients10.1016/j.arth.2011.03.020 ↗
8. Micromotion of plasma spray versus grit-blasted radial head prosthetic stem surfaces10.1016/j.jse.2010.11.010 ↗
9. Evaluation of acetabular stability in uncemented prostheses10.1016/S0883-5403(06)80185-3 ↗
10. A novel method to assess primary stability of press-fit acetabular cups10.1177/0954411914557714 ↗
11. Cementless total hip arthroplasty: a review10.1515/bmt.2010.037 ↗
12. Effenberger, H., 2007. Hüftendoprothetik - Konstruktion, Klassifikation, Implantate, Ergebnisse. Krankenhaus Tamsweg.
13. Laser additive manufacturing of modified implant surfaces with osseointegrative characteristics10.1016/j.phpro.2011.03.048 ↗
14. Biomimetic approaches in bone tissue engineering: integrating biological and physicomechanical strategies10.1016/j.addr.2014.09.005 ↗
15. Effect of process parameters on the surface roughness of overhanging structures in laser powder bed fusion additive manufacturing10.1016/j.procir.2016.02.347 ↗
16. In-vitro and in-vivo investigations of the impaction and pull-out behavior of metal-backed acetabular cups
17. Gollwitzer · 2006
18. Preclinical trial of a novel surface architecture for improved primary fixation of cementless orthopaedic implants10.1016/j.clinbiomech.2014.07.007 ↗
19. Micromotion and friction evaluation of a novel surface architecture for improved primary fixation of cementless orthopaedic implants10.1016/j.jmbbm.2013.01.017 ↗
20. The potential application of a Cobalt Chrome Molybdenum femoral stem with functionally graded orthotropic structures manufactured using laser melting technologies10.1016/j.mehy.2013.10.012 ↗
21. Radiographic fit and fill analysis of a new second-generation proximally coated cementless stem compared to its predicate design10.1016/j.arth.2013.04.029 ↗
22. Biomechanical qualities of threaded acetabular cups10.1007/s00264-002-0368-y ↗
23. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation10.1016/j.medengphy.2014.07.003 ↗
24. Surface treatments of titanium dental implants for rapid osseointegration10.1016/j.dental.2006.06.025 ↗
25. A new era in porous metals: applications in orthopaedics10.1002/adem.200800215 ↗
26. Fabrication, pore structure and compressive behavior of anisotropic porous titanium for human trabecular bone implant applications10.1016/j.jmbbm.2015.02.023 ↗
27. Titanium alloys in total joint replacement - a materials science perspective10.1016/S0142-9612(97)00146-4 ↗
28. Press-fit acetabular cup fixation: principles and testing10.1243/0954411991534780 ↗
29. Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: trabecular titanium10.1016/j.jmbbm.2010.02.001 ↗
30. Morlock · 2002
31. Do human osteoblasts grow into open-porous titanium?10.22203/eCM.v011a02 ↗
32. Open-cellular metal implant design and fabrication for biomechanical compatibility with bone using electron beam melting
33. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays10.1098/rsta.2010.0010 ↗
34. Finite element study of scaffold architecture design and culture conditions for tissue engineering10.1016/j.biomaterials.2009.07.041 ↗
35. Comparative in vitro assessment of the primay stbility of cementless press-fit acetabular cups
36. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)10.1016/j.jmbbm.2009.10.006 ↗
37. Metallic microlattice materials: a current state of the art on manufacturing, mechanical properties and applications10.1016/j.matdes.2016.01.146 ↗
38. Effect of cementless acetabular cup geometry on strain distribution and press-fit stability10.1016/S0883-5403(97)90068-1 ↗
39. Press fit fixation of cementless cups: how much stability do we need indeed?10.1007/s00402-005-0001-9 ↗
40. Auxetic cellular structures through selective electron-beam melting10.1002/pssb.200945513 ↗
41. Development of a porous metallic femoral stem: design, manufacturing, simulation and mechanical testing10.1016/j.matdes.2016.10.064 ↗
42. Laser and electron-beam powder-bed additive manufacturing of metallic implants: a review on processes, materials and designs10.1002/jor.23075 ↗
43. High initial stability in porous titanium acetabular cups: a biomechanical study10.1016/j.arth.2012.07.035 ↗
44. Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability10.1080/10255842.2011.561012 ↗
45. Mechanical equivalent diameter of single struts for the stiffness prediction of lattice structures produced by Electron Beam Melting
46. Does the ingrowth surface make a difference? A retrieval study of 423 cementless acetabular components10.1016/j.arth.2014.10.028 ↗
47. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction—an in vitro biomechanical study10.1007/s00590-014-1571-4 ↗
48. Mechanical properties and osteoconductivity of porous bioactive titanium10.1016/j.biomaterials.2005.03.019 ↗
49. Acetabular components in total hip arthroplasty: Is there evidence that cementless fixation is better?10.2106/JBJS.K.01652 ↗
50. Titanium - the implant material of today10.1007/BF01133326 ↗
51. Porous titanium scaffolds produced by powder metallurgy for biomedical applications10.1590/S1516-14392008000300008 ↗
52. Effects of build orientation and heat treatment on the microstructure and mechanical properties of selective laser melted Ti6Al4 V lattice structures
53. Performance of porous tantalum vs. titanium cup in total hip arthroplasty: randomized trial with minimum 10-year follow-up10.1016/j.arth.2015.01.013 ↗
54. Influence of the structural orientation on the mechanical properties of selective laser melted Ti6Al4V open-porous scaffolds
55. Comparison of single Ti6Al4V struts made using selective laser melting and electron beam melting subject to part orientation10.3390/met7030091 ↗
56. Specific yielding of selective laser-melted Ti6Al4V open-porous scaffolds as a function of unit cell design and dimensions
57. An overview of densification, microstructure and mechanical property of additively manufactured Ti-6Al-4V — comparison among selective laser melting, electron beam melting, laser metal deposition and selective laser sintering, and with conventional powder
58. Wear testing of total hip replacements under severe conditions10.1586/17434440.2015.1050378 ↗