journal article·2020-02

An experimental and computational investigation of the effects of volumetric boundary conditions on the compressive mechanics of passive skeletal muscle

Anurag J. Vaidya, Benjamin B. Wheatley

Publisher page

Abstract

Computational modeling, such as finite element analysis, is employed in a range of biomechanics specialties, including impact biomechanics and surgical planning. These models rely on accurate material properties for skeletal muscle, which comprises roughly 40% of the human body. Due to surrounding tissues, compressed skeletal muscle in vivo likely experiences a semi-confined state. Nearly all previous studies investigating passively compressed muscle at the tissue level have focused on muscle in unconfined compression. The goals of this study were to (1) examine the stiffness and time-dependent material properties of skeletal muscle subjected to both confined and unconfined compression (2) develop a model that captures passive muscle mechanics under both conditions and (3) determine the extent to which different assumptions of volumetric behavior affect model results. Muscle in confined compression exhibited stiffer behavior, agreeing with previous assumptions of near-incompressibility. Stress relaxation was found to be faster under unconfined compression, suggesting there may be different mechanisms that support load these two conditions. Finite element calibration was achieved through nonlinear optimization (normalized root mean square error <6%) and model validation was strong (normalized root mean square error <17%). Comparisons to commonly employed assumptions of bulk behavior showed that a simple one parameter approach does not accurately simulate confined compression. We thus recommend the use of a properly calibrated, nonlinear bulk constitutive model for modeling of skeletal muscle in vivo. Future work to determine mechanisms of passive muscle stiffness would enhance the efforts presented here.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Sports injuries and prevention · Prosthetics and Rehabilitation Robotics · Muscle activation and electromyography studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (57)

Show source-provided references
1. Dynamic stiffness and damping of porcine muscle specimens10.1016/S1350-4533(03)00103-6 ↗
2. A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii10.1016/j.jbiomech.2004.04.009 ↗
3. Investigating the passive mechanical behaviour of skeletal muscle fibres: micromechanical experiments and Bayesian hierarchical modelling10.1016/j.actbio.2019.05.015 ↗
4. “Compressive properties of passive skeletal muscle—the impact of precise sample geometry on parameter identification in inverse finite element analysis10.1016/j.jbiomech.2012.08.023 ↗
5. On the anisotropy of skeletal muscle tissue under compression10.1016/j.actbio.2014.03.003 ↗
6. Long-term mechanical behaviour of skeletal muscle tissue in semi-confined compression experiments10.1016/j.jmbbm.2016.06.012 ↗
7. Passive transverse mechanical properties of skeletal muscle under in vivo compression10.1016/S0021-9290(01)00083-5 ↗
8. On modelling damage process in vaginal tissue10.1016/j.jbiomech.2008.12.002 ↗
9. Passive nonlinear elastic behaviour of skeletal muscle: experimental results and model formulation10.1016/j.jbiomech.2009.08.032 ↗
10. Characterization of human passive muscles for impact loads using genetic algorithm and inverse finite element methods10.1007/s10237-008-0121-6 ↗
11. In vivo muscle stiffening under bone compression promotes deep pressure sores10.1115/1.1894386 ↗
12. A structural model of passive skeletal muscle shows two reinforcement processes in resisting deformation10.1016/j.jmbbm.2013.02.007 ↗
13. A 3D active-passive numerical skeletal muscle model incorporating initial tissue strains. Validation with experimental results on rat tibialis anterior muscle10.1007/s10237-010-0273-z ↗
14. Residual stress produced by ventricular volume reduction surgery has little effect on ventricular function and mechanics: a finite element model study10.1067/mtc.2001.114939 ↗
15. Holzapfel · 2001 · 1049
16. Skeletal muscle mass and distribution in 468 men and women aged 18-88 yr10.1152/jappl.2000.89.1.81 ↗
17. Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI10.1016/j.jbiomech.2016.09.002 ↗
18. Inverse finite element characterization of soft tissues10.1016/S1361-8415(02)00085-3 ↗
19. Deformable modeling of facial tissue for craniofacial surgery simulation10.3109/10929089809149844 ↗
20. Characterization of viscoelastic soft tissue properties from in vivo animal experiments and inverse FE parameter estimation
21. Importance of the superficial tissue layer for the indentation stiffness of articular cartilage10.1016/S1350-4533(01)00123-0 ↗
22. Computer-aided design of a prosthetic socket for an above-knee amputee
23. A continuum model for tension-compression asymmetry in skeletal muscle10.1016/j.jmbbm.2017.09.012 ↗
24. Inverse analysis of constitutive models: biological soft tissues10.1016/j.jbiomech.2006.03.014 ↗
25. Experimental and biphasic FEM determinations of the material properties and hydraulic permeability of the meniscus in tension10.1115/1.1468868 ↗
26. Assessment of mechanical conditions in sub-dermal tissues during sitting: a combined experimental-MRI and finite element approach10.1016/j.jbiomech.2006.06.020 ↗
27. A validated model of passive muscle in compression10.1016/j.jbiomech.2005.10.016 ↗
28. Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling10.1016/j.jbiomech.2008.02.007 ↗
29. Viscoelastic properties of passive skeletal muscle in compression-Cyclic behaviour10.1016/j.jbiomech.2009.02.022 ↗
30. Viscoelastic properties of the cervical spinal ligaments under fast strain-rate deformations10.1016/j.actbio.2007.08.003 ↗
31. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review
32. A comparative study of several material models for prediction of hyperelastic properties: application to silicone-rubber and soft tissues10.1111/j.1475-1305.2006.00257.x ↗
33. “Control of tension–compression asymmetry in Ogden hyperelasticity with application to soft tissue modelling10.1016/j.jmbbm.2015.11.027 ↗
34. The in vitro passive elastic response of chicken pectoralis muscle to applied tensile and compressive deformation10.1016/j.jmbbm.2016.05.021 ↗
35. Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling10.1115/1.2264395 ↗
36. Anisotropic compressive properties of passive porcine muscle tissue10.1115/1.4028088 ↗
37. The development, validation and application of a finite element upper extremity model subjected to air bag loading
38. Muscle force depends on the amount of transversal muscle loading10.1016/j.jbiomech.2014.03.029 ↗
39. Three-dimensional muscle architecture and comprehensive dynamic properties of rabbit gastrocnemius, plantaris and soleus: input for simulation studies10.1371/journal.pone.0130985 ↗
40. Extra- and intracellular water spaces in muscles of man at rest and with dynamic exercise
41. Incompressible fluid plays a mechanical role in the development of passive muscle tension10.1098/rsbl.2016.0630 ↗
42. High strain rate compressive properties of bovine muscle tissue determined using a split Hopkinson bar apparatus10.1016/j.jbiomech.2005.05.015 ↗
43. Dynamic and quasi-static compressive response of porcine muscle10.1016/j.jbiomech.2007.02.001 ↗
44. Systèmes · 2012
45. The anisotropic mechanical behaviour of passive skeletal muscle tissue subjected to large tensile strain10.1016/j.jmbbm.2012.09.001 ↗
46. Human cervical spine ligaments exhibit fully nonlinear viscoelastic behavior10.1016/j.actbio.2010.09.003 ↗
47. A finite element model of the human buttocks for prediction of seat pressure distributions10.1080/10255840410001727832 ↗
48. Modeling the effects of blast on the human thorax using high strain rate viscoelastic properties of human tissue
49. An optimized transversely isotropic, hyper-poro-viscoelastic finite element model of the meniscus to evaluate mechanical degradation following traumatic loading10.1016/j.jbiomech.2015.02.028 ↗
50. Skeletal muscle tensile strain dependence: hyperviscoelastic nonlinearity10.1016/j.jmbbm.2015.08.041 ↗
51. Fully non-linear hyper-viscoelastic modeling of skeletal muscle in compression10.1080/10255842.2015.1118468 ↗
52. How does tissue preparation affect skeletal muscle transverse isotropy?10.1016/j.jbiomech.2016.06.034 ↗
53. Modeling skeletal muscle stress and intramuscular pressure: a whole muscle active–passive approach10.1115/1.4040318 ↗
54. A case for poroelasticity in skeletal muscle finite element analysis: experiment and modeling10.1080/10255842.2016.1268132 ↗
55. The possible role of poroelasticity in the apparent viscoelastic behavior of passive cardiac muscle10.1016/0021-9290(91)90291-T ↗
56. Objective assessment of limb tissue elasticity: development of a manual indentation procedure
57. Objective assessment of limb tissue elasticity: development of a manual indentation procedure