journal article·2021-12Open access

Evaluation of depth-wise post-gel polymerisation shrinkage behaviour of flowable dental composites

Sonam Behl, Ginu Rajan, Raju, Paul Farrar, Leon Prentice, B. Gangadhara Prusty

Abstract

Short fibre reinforced flowable dental composites are gaining acceptance over particulate filled composites due to their competence to impart improved physio-mechanical properties and capability to prevent crack propagation. However, limited research exists to assess their overall post-gel shrinkage behaviour, which is an important factor to determine marginal seal around restoration and hence its longevity. In this paper, depth-wise post-gel shrinkage strain and the resulting factors such as degree of conversion and rheological behaviour of flowable fibre reinforced composite (FRC) containing 5% weight fraction of 5 μm diameter, 350 μm length S-Glass fibres in UDMA/TEGDMA mixture along with 50% strontium filler particles were investigated. Post-gel shrinkage strain was measured using an array of optical fibre Bragg grating sensors (FBGs) of diameter 250 μm and length 1 mm each embedded at three different depths (depth 0 mm, depth 2.5 mm and depth 5 mm from curing light tip) within the flowable dental composite samples. The rheological behaviour during the polymerisation process was carried out using dynamic oscillatory tests. To evaluate the conversion of CC during polymerisation, degree of conversion tests were conducted by using FTIR spectroscopy. The results obtained for FRC samples were further compared with that of particulate filled composite (PFC) samples, with 55% strontium filler particles only within the same resin system. The relationship between post-gel shrinkage strain at different depths, rheological behaviour and degree of conversion was also explored. The experimental results from the sensor embedded materials suggested that the post-gel shrinkage strain was higher at the top surface (depth 0 mm) and was 50% more than at the bottom surface (depth of 5 mm) for dental FRC as well as PFC samples. Further, similar flow behaviour and not significant different (p<0.05) degree of conversion (DC), post-gel shrinkage strain for dental PFC and FRC composites was observed, establishing a convincing positive relationship between all the key factors and further implying that replacement of fibres with fillers did not affect the overall post-gel polymerisation shrinkage behaviour in dental composites. This investigation has also demonstrated that fibre optic sensors-based shrinkage measurements can be an ideal technique to evaluate post-gel shrinkage performance of dental resins with PFCs or FRCs.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Temporomandibular Joint Disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Degree of conversion and surface hardness of bulk-fill composite versus incremental-fill composite10.1016/j.tdj.2015.01.003 ↗
2. Evaluation of polymerization shrinkage and hydroscopic expansion of fiber-reinforced biocomposites using optical fiber Bragg grating sensors10.1016/j.dental.2008.07.006 ↗
3. Flow, strength, stiffness and radiopacity of flowable resin composites
4. Flowable resin composites: a systematic review and clinical considerations
5. Physical and mechanical characterisation of flowable dental composites reinforced with short aspect ratio micro-sized S-Glass fibres10.1016/j.msec.2020.110771 ↗
6. Evaluation of rheological behaviour of flowable dental composites reinforced with low aspect ratio micro-sized glass fibres10.1016/j.dental.2020.10.023 ↗
7. Incremental filling technique and composite material-Part II: shrinkage and shrinkage stresses10.2341/12-442-L ↗
8. Effect of temperature and humidity on post-gel shrinkage, cusp deformation, bond strength and shrinkage stress - construction of a chamber to simulate the oral environment10.1016/j.dental.2015.09.023 ↗
9. Replacement of glass particles by multidirectional short glass fibers in experimental composites: effects on degree of conversion, mechanical properties and polymerization shrinkage10.1016/j.dental.2016.06.008 ↗
10. Fracture toughness of nine flowable resin composites10.1067/mpr.2003.33 ↗
11. Alternatives in polymerization contraction stress management10.1177/154411130401500306 ↗
12. Degree of conversion and mechanical properties of a BisGMA:TEGDMA composite as a function of the applied radiant exposure10.1002/jbm.b.30897 ↗
13. Comparison of post-gel shrinkage strains in light-polymerized composite resins10.1067/mpr.2002.129080 ↗
14. Incremental techniques in direct composite restoration10.4103/JCD.JCD_157_16 ↗
15. Selective atomic-level etching on short S-glass fibres to control interfacial properties for restorative dental composites10.1038/s41598-019-40524-7 ↗
16. Volume contraction in photocured dental resins: the shrinkage-conversion relationship revisited10.1016/j.dental.2005.03.014 ↗
17. Light transmittance and polymerization of bulk-fill composite materials doped with bioactive micro-fillers10.3390/ma12244087 ↗
18. Post-gel shrinkage strain and degree of conversion of preheated resin composite cured using different regimens10.2341/09-072-L ↗
19. The effect of resin matrix composition on the polymerization shrinkage and rheological properties of experimental dental composites10.1016/j.dental.2006.11.004 ↗
20. Resin composite--state of the art10.1016/j.dental.2010.10.020 ↗
21. Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips
22. Mechanical properties and wear of five commercial fibre-reinforced filling materials
23. Short fiber‐reinforced composite restorations: a review of the current literature10.1111/jicd.12330 ↗
24. A comparative study of bulk-fill composites: degree of conversion, post-gel shrinkage and cytotoxicity10.1590/1807-3107bor-2018.vol32.0017 ↗
25. Resin composite restorative materials10.1111/j.1834-7819.2010.01296.x ↗
26. An update on glass fiber dental restorative composites: a systematic review10.1016/j.msec.2014.11.015 ↗
27. The effect of fiber position and polymerization condition on the flexural properties of fiber-reinforced composite10.5005/jcdp-5-2-14 ↗
28. Mechanical properties and fracture behavior of flowable fiber reinforced composite restorations10.1016/j.dental.2018.01.002 ↗
29. Mechanical properties and fracture behavior of flowable fiber reinforced composite restorations10.1016/j.dental.2018.01.002 ↗
30. Characterization of a new fiber-reinforced flowable composite10.1007/s10266-018-0405-y ↗
31. Characterization of restorative short-fiber reinforced dental composites10.4012/dmj.2019-088 ↗
32. Recent advances in the development of dental composite resins10.1039/C1RA00922B ↗
33. Measurement of composite shrinkage using a fibre optic Bragg grating sensor10.1163/156856207780425004 ↗
34. Polymerization profile analysis of resin composite dental restorative materials in real time10.1016/j.jdent.2011.10.006 ↗
35. Evaluation of the physical properties of dental resin composites using optical fiber sensing technology10.1016/j.dental.2016.06.015 ↗
36. Polymerisation shrinkage profiling of dental composites using optical fibre sensing and their correlation with degree of conversion and curing rate10.1038/s41598-019-40162-z ↗
37. In situ measurement of dental resin-based composite volumetric shrinkage and temperature effects using in-fibre bragg grating methods10.1016/j.jmbbm.2019.03.026 ↗
38. Mechanical properties, shrinkage stress, cuspal strain and fracture resistance of molars restored with bulk-fill composites and incremental filling technique10.1016/j.jdent.2015.09.007 ↗
39. Reduced light energy density decreases post-gel contraction while maintaining degree of conversion in composites10.1016/S0300-5712(97)00048-1 ↗
40. Analysis of strain gage method for measurement of post-gel shrinkage in resin composites10.1016/S0109-5641(97)80034-6 ↗
41. Polymerization shrinkage stresses in a premolar restored with different composite resins and different incremental techniques
42. High-aspect ratio fillers: fiber-reinforced composites and their anisotropic properties10.1016/j.dental.2014.07.009 ↗
43. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials10.1080/23337931.2018.1457445 ↗
44. Photo-polymerization shrinkage-stress kinetics in resin-composites: methods development10.1016/S0109-5641(02)00123-9 ↗
45. Yap · 2004 · vol. 29 · 182
46. Measurement of thermal expansion coefficients using an in-fibre Bragg-grating sensor10.1088/0957-0233/9/9/025 ↗
47. Bulk-fill resin composites: polymerization properties and extended light curing10.1016/j.dental.2014.12.010 ↗