Mechanical characterization and finite element implementation of the soft materials used in a novel anthropometric test device for simulating underbody blast loading
Source abstract
Abstract
Soft materials (e.g. polymers) are widely used in biomechanical devices to represent the nonlinear viscoelastic properties inherent in biological soft tissues. Knowledge of their mechanical properties is used to inform design choices and develop accurate finite element (FE) models of human surrogates. The goal of this study was to characterize the behavior of eight polymeric materials used in the design of a novel anthropomorphic test device (ATD) and implement these materials in an FE model of the ATD. Tensile and compressive tests at strain rates ranging from 0.01s-1 to 1000s-1 were conducted on specimens from each material. Stress-strain relationships at discrete strain rates were used to define strain rate-dependent hyper-elastic material models in a commercial finite element solver. Then, the material models were implemented into an FE model of the ATD. The performance of the material models in the FE model was evaluated by simulating experiments that were conducted on the ATD lower limb. The material characterization tests revealed viscoelastic strain rate-dependent properties in the flesh and compliant elements of the ATD. Higher modulus polymers exhibited rate-dependent, strain-hardening properties. A strong agreement was seen between the material model simulations and corresponding experiments. In component simulations, the materials performed well and the model reasonably predicted the forces observed in experiments.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Automotive and Human Injury Biomechanics · Elasticity and Material Modeling · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. ASTM · 2014
2. ASTM · 2015
3. Comparison of Hybrid-III and postmortem human surrogate response to simulated underbody blast loading10.1115/1.4029981 ↗
4. Baker, A.W., Untaroiu, C., Chowhurdy, M., 2015. Development of a finite element model of the WIAMan lower extremity to investigate under-body blasts. In: Proceedings of the 14th International LS-DYNA Users Conference. Detroit.
5. Validation of lower limb surrogates as injury assessment tools in floor impacts due to anti-vehicular land mines10.7205/MILMED.173.12.1180 ↗
6. Chowhurdy · 2017
7. Chowhurdy · 2017
8. Human surrogates for injury biomechanics research10.1002/ca.21152 ↗
9. Crawford · 2016
10. Davidsson, J., Svensson, M.Y., Flogård, A., Håland, Y., Jakobsson, L., Linder, A., Lövsund, P., Wiklund, K., 1998. BioRID I: a new biofidelic rear impact dummy. In: Proceedings of the International Research Council on the Biomechanics of Injury Conference. International Research Council on Biomechanics of Injury, pp. 377–390.
11. Development of dummy and injury index for NHTSA's thoracic side impact protection research program10.4271/840885 ↗
12. Hybrid III-a biomechanically-based crash test dummy10.4271/770938 ↗
13. Gray · 2000 · 2000 · 462
14. Haffner, M., Eppinger, R., Rangarajan, N., Shams, T., Artis, M., Beach, D., 2001. Foundations and elements of the NHTSA THOR alpha ATD design. In: Proceedings of the 17th ESV Conference Paper.
15. LS-DYNA keyword user’s manual
16. Development and testing of a more realistic pelvis for the Hybrid III 6-year-old ATD10.1080/15389588.2010.506502 ↗
17. A tabulated formulation of hyperelasticity with rate effects and damage10.1007/s00466-006-0150-x ↗
18. Kolsky, H., 1949. An investigation of the mechanical properties of materials at very high rates of loading. In: Proceedings of the Physical Society. Section B 62, 676.10.1088/0370-1301/62/11/302 ↗
19. McKay · 2010
20. Merkle, A., Voo, L., Ott, K., Dooley, C., Carneal, C., 2012. APL Status Update, Medical Research Meeting, Sept 11-12, Ft. Rucker.
21. Anthropomorphic Test Devices and Injury Risk Assessments
22. The dynamic behaviour of the floor of a surrogate vehicle under explosive blast loading
23. A validated numerical model of a lower limb surrogate to investigate injuries caused by under-vehicle explosions10.1016/j.jbiomech.2016.02.007 ↗
24. Newell, N., Masouros, S.D., Ramasamy, A., Bonner, T.J., Hill, A.M., Clasper, J.C., Bull, A.M., 2012. Use of Cadavers and Anthropometric Test Devices (ATDs) for Assessing Lower Limb Injury Outcome from Under-vehicle Explosions.
25. Large deformation isotropic elasticity-on the correlation of theory and experiment for incompressible rubberlike solids10.1098/rspa.1972.0026 ↗
26. Development, calibration, and validation of a head-neck complex of THOR mod kit finite element model10.1080/15389588.2014.880886 ↗
27. Development and evaluation of a finite element model of the THOR for occupant protection of spaceflight crewmembers10.1016/j.aap.2015.05.002 ↗
28. Injuries from roadside improvised explosive devices10.1097/TA.0b013e3181848cf6 ↗
29. In-vehicle extremity injuries from improvised explosive devices: current and future foci10.1098/rstb.2010.0219 ↗
30. Outcomes of IED foot and ankle blast injuries10.2106/JBJS.K.01666 ↗
31. Ridella, S., Parent, D., 2011. Modifications to improve the durability, usability, and biofidelity of the THOR-NT dummy. In: Proceedings of the 22nd ESV Conference Paper.
32. Untaroiu · 2005
33. Performance- based Classification of Occupant Posture to Reduce the Risk of Injury in a Collision10.1109/TITS.2012.2223687 ↗
34. Crash reconstruction of pedestrian accidents using optimization techniques10.1016/j.ijimpeng.2008.01.012 ↗
35. Constrained Design Optimization of Rotor-Tilting Pad Bearings Systems10.1115/1.4001811 ↗
36. Comparison of Hybrid III, thor-alpha and PMHS response in frontal sled tests
37. Improvised explosive devices (IEDs) in Iraq and Afghanistan: effects and countermeasures