Characterisation and constitutive modelling of biaxially stretched poly(L-lactic acid) sheet for application in coronary stents
Source abstract
Abstract
A poly(L-lactic acid) stent is exposed to a variety of processing techniques, temperatures and environmental conditions during its lifecycle, from the manufacturing process, to crimping through to deployment within the body. The effect of the biaxial stretching procedure and the effects of temperature and extension rate (post-processing) on the mechanical response of poly(L-lactic acid) are hereby investigated, and a constitutive model calibrated against experimental data is proposed. Dumb-bell specimens were punched from biaxially stretched sheets subjected to different processing histories, and tested under uniaxial tension at various temperatures (20, 37 and 55 °C) and extension rates (1, 5 and 10 mm/min). A Design of Experiments methodology was employed to identify the parameters that had the most significant effect on the mechanical response of the polymer. Results show that the elastic modulus and yield strength of the stretched sheets are strongly dependent on the aspect ratio of the biaxial deformation, along with the temperature during uniaxial deformation (post-processing). In contrast, these mechanical properties were not heavily dependent on extension rate (post-processing). A transversely isotropic, elastic-plastic constitutive model for finite element implementation is proposed, with the intention that it may be used as a design tool for developing high stiffness, thin-strut polymeric stents that contend with the performance of their metallic counterparts.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: biodegradable polymer synthesis and properties · Electrospun Nanofibers in Biomedical Applications · Polymer Nanocomposites and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. US Food and Drug Administration · 2010
2. Abbott · 2012
3. Materials and manufacturing technologies available for production of a pediatric bioabsorbable stent10.1155/2013/137985 ↗
4. Importance of anisotropy when estimating and measuring in situ stresses in rock10.1016/0148-9062(95)00062-3 ↗
5. Effects of stent design parameters on normal artery wall mechanics10.1115/1.2246236 ↗
6. Bergström · 2015
7. An overview of mechanical properties and material modeling of polylactide (PLA) for medical applications10.1007/s10439-015-1455-8 ↗
8. Processing-property relationships of biaxially stretched poly(L-lactic acid) sheet for application in coronary stents10.1016/j.jmbbm.2018.06.017 ↗
9. Computational analysis of the utilisation of the shape memory effect and balloon expansion in fully polymeric stent deployment10.1007/s13239-017-0333-y ↗
10. Computational bench testing to evaluate the short-term mechanical performance of a polymeric stent10.1007/s13239-015-0235-9 ↗
11. Experimental mechanical testing of Poly (l-Lactide) (PLLA) to facilitate pre-degradation characteristics for application in cardiovascular stenting10.1016/j.polymertesting.2016.07.011 ↗
12. Bioresorbable scaffolds: current knowledge, potentialities and limitations experienced during their first clinical applications10.1016/j.ijcard.2012.05.093 ↗
13. Bioresorbable scaffold—a magic bullet for the treatment of coronary artery disease?10.1016/j.ijcard.2016.04.027 ↗
14. Deformation and strength anisotropy of Asan gneiss, Boryeong shale, and Yeoncheon schist10.1016/j.ijrmms.2011.12.004 ↗
15. Cowin · 2013
16. A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent10.1016/j.jbiomech.2015.03.024 ↗
17. Algorithms for the reduction of the number of points required to represent a digitized line or its caricature10.3138/FM57-6770-U75U-7727 ↗
18. Material modeling of polylactide
19. Physical and mechanical properties of PLA, and their functions in widespread applications—a comprehensive review10.1016/j.addr.2016.06.012 ↗
20. Mechanical properties of laser cut poly (L-lactide) micro-specimens: implications for stent design, manufacture, and sterilization10.1115/1.1835349 ↗
21. Comparative study of the dynamic glass transition temperature by DMA and TMDSC10.1016/j.polymertesting.2010.09.005 ↗
22. The effect of static and dynamic loading on degradation of PLLA stent fibers10.1115/1.4027614 ↗
23. Hibbitt · 2016
24. A theory of the yielding and plastic flow of anisotropic metals
25. Matplotlib: a 2D graphics environment10.1109/MCSE.2007.55 ↗
26. ISO Standard 527-2 · 1996
27. Jow · 2017
28. Stents: biomechanics, biomaterials, and insights from computational modeling10.1007/s10439-017-1806-8 ↗
29. Recent advances in high performance poly (lactide): from “green” plasticization to super-tough materials via (reactive) compounding10.3389/fchem.2013.00032 ↗
30. A phenomenological constitutive model for the nonlinear viscoelastic responses of biodegradable polymers10.1007/s00707-012-0760-7 ↗
31. Cardiovascular stent design and vessel stresses: a finite element analysis10.1016/j.jbiomech.2004.07.022 ↗
32. Multi-objective optimizations of biodegradable polymer stent structure and stent microinjection molding process10.3390/polym9010020 ↗
33. Processing technologies for poly (lactic acid)10.1016/j.progpolymsci.2008.05.004 ↗
34. Characterization of biaxial strain of poly (l‐lactide) tubes10.1002/pi.5040 ↗
35. Ludman · 2016
36. Poly (lactic acid): plasticization and properties of biodegradable multiphase systems10.1016/S0032-3861(01)00086-6 ↗
37. Biaxial characterisation of materials for thermoforming and blow moulding10.1179/174328905X64803 ↗
38. Menard · 2008
39. A predictive study of the mechanical behaviour of coronary stents by computer modelling10.1016/j.medengphy.2004.08.012 ↗
40. Modeling the response of nonlinear viscoelastic biodegradable polymeric stents10.1016/j.ijsolstr.2011.12.007 ↗
41. Oliphant · 2006
42. Ottosen · 2005
43. Geometry parameterization and multidisciplinary constrained optimization of coronary stents10.1007/s10237-011-0293-3 ↗
44. Computational analysis of the radial mechanical performance of PLLA coronary artery stents10.1016/j.medengphy.2014.09.014 ↗
45. Python Software Foundation · 2018
46. R Core Team · 2017
47. An iterative procedure for the polygonal approximation of plane curves10.1016/S0146-664X(72)80017-0 ↗
48. Atherosclerosis—an inflammatory disease10.1056/NEJM199901143400207 ↗
49. Sur la distribution des élasticités autour de chaque point d’un solide ou d’un milieu de contexture quelconque, particulièrement lorsqu’il est amorphe sans être isotrope
50. Finite-element-analysis and in vitro study of bioabsorbable polymer stent designs
51. Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes10.1016/j.jacc.2011.05.050 ↗
52. Mechanical properties, morphologies, and crystallization behavior of plasticized poly (L-lactide)/poly (butylene succinate-co-L-lactate) blends10.1016/j.polymer.2007.02.065 ↗
53. Constitutive framework for biodegradable polymers with applications to biodegradable stents10.1097/MAT.0b013e31816ba55a ↗
54. Staab · 2015
55. Risk of stent thrombosis among bare-metal stents, first-generation drug-eluting stents, and second-generation drug-eluting stents: results from a registry of 18,334 patients10.1016/j.jcin.2013.06.015 ↗
56. Rates of primary percutaneous coronary intervention worldwide10.1253/circj.69.95 ↗
57. U S Food and Drug Administration · 2016
58. Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents10.1016/j.jmbbm.2016.08.033 ↗
59. Current status of bioresorbable scaffolds in the treatment of coronary artery disease10.1016/j.jacc.2014.09.041 ↗
60. World Health Organization · 2012
61. World Health Organization · 2017
62. Topology optimization of a novel stent platform with drug reservoirs10.1016/j.medengphy.2008.02.010 ↗
63. Effect of biaxial stretching on thermal properties, shrinkage and mechanical properties of poly (lactic acid) films10.1007/s10924-012-0523-5 ↗
64. Some forms of the strain energy function for rubber10.5254/1.3538343 ↗