Comparative study of the fatigue strength of five acrylic denture resins
Source abstract
Abstract
The aim of this in vitro study was to compare the fatigue resistance of three kinds of heat-polymerized acrylic resins (conventional heat-polymerized, rapid heat-polymerized, high impact acrylic resin), a kind of visible light-cured resin and a kind of self-cured acrylic resin. A total of 60 notched and un-notched specimens (65 mm x 10 mm x 3 mm) were fabricated, 12 from each material. The fatigue resistance was measured by applying repeated three-point bending deflection to the specimens. For statistical analysis, Kruskal-Wallis test followed by Dunn's multiple comparison tests were used. The Kruskal-Wallis test revealed significant differences in the fatigue resistance among some groups (p<0.05). Conventional- and rapid-heat polymerized resins had lower fatigue resistance values than heat-polymerized high impact acrylic resin, but the differences were statistically non-significant according to Dunn's test (p>0.05). High impact acrylic resin was also found to have significantly higher fatigue resistance value than that of self-cured resin and light-cured resin (p<0.05). Further, there was no statistically significant difference between the mean fatigue resistance value of visible light-cured resin and self-cured resin (p>0.05).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Some physical and mechanical properties of a visible light-activated-material10.1016/S0109-5641(88)80064-2 ↗
2. Anusavice · 1996
3. An analysis of causes of fracture of acrylic dentures10.1016/0022-3913(81)90206-7 ↗
4. Craig · 2002
5. Denture fracture—a survey10.1038/sj.bdj.4808449 ↗
6. Flexural and fatigue strengths of denture base resin10.1016/S0022-3913(08)60136-5 ↗
7. Mechanical properties of a light-polymerizing provisional restorative material with and without reinforcement fibers10.1016/S0022-3913(05)80108-8 ↗
8. Fatigue properties of acrylic denture base resins10.4012/dmj.8.243 ↗
9. Effect of glass fiber orientation on the fatigue resistance of acrylic resin denture base
10. Flexure fatigue of 10 commonly used denture base resins10.1016/0022-3913(81)90232-8 ↗
11. Fatigue failure in denture base polymers10.1016/0022-3913(69)90289-3 ↗
12. The staining charecteristics, transverse strength and microhardness of a visible light-cured denture base material10.1016/0022-3913(87)90319-2 ↗
13. Comparative study of the transverse strength of three denture base materials10.1016/j.jdent.2007.09.006 ↗
14. Nutt · 1976 · vol. 360
15. Q’Brien · 2002
16. Fatigue resistance of removable orthodontic appliance reinforced with glass fiber weave10.1046/j.1365-2842.2003.01108.x ↗
17. Effect of relining, water storage and cyclic loading on the flexural strength of a denture base acrylic resin10.1016/j.jdent.2005.10.001 ↗
18. Acrylic denture. Mechanical evaluation; midline fracture
19. Fatigue of testing of denture base polymers10.1111/j.1365-2842.1982.tb00544.x ↗
20. Flexural fatigue tests of some denture base polymers10.1038/sj.bdj.4802483 ↗
21. Adaptation of a visible light-cured denture base material10.1016/0022-3913(89)90138-8 ↗
22. Comparison of in-vitro fatique resistance of acrylic resin partial denture reinforced with continuous glass fibres or metal wire10.1111/j.1532-849X.1996.tb00285.x ↗
23. In vitro fatigue fracture of an acrylic resin-based partial denture: an exploratory study10.1016/0022-3913(94)90342-5 ↗
24. The effect of notch shape and self-cured acrylic resin repair on the fatigue resistance of an acrylic resin denture base10.1111/j.1365-2842.1996.tb01218.x ↗
25. Stress fatigue: basic principles and prosthodontic implications