Biomechanical stimuli play a major role in fracture healing. Changing the fixation stiffness through the course of healing might accelerate bone healing and prevent healing complications. Shape memory alloy (SMA) based implants were developed to allow for non-invasive stiffness alteration during the fracture healing process. To gain a deeper understanding of the implant functionality based on the alloy characteristics and geometric design, the mechanical properties of different shape memory alloys where mechanically characterized. SMA bone plates were manufactured and the structural bending stiffness of the implants was determined at different temperatures and configurations. The temperature required for complete recovery of shape after deformation increased continuously with increasing pseudo-plastic deformation in SMA probes. Full recovery was observed at temperatures ranging from 38°C to 52°C after pseudo-plastic deformations ranging from 0.2% to 1.0% outer fibre strain, respectively. The small fragment inverse-dynamisation implants revealed bending stiffnesses ranging from 0.09Nm2 to 0.34Nm2 in the initial state and from 0.16Nm2 to 0.46Nm2 after shape alteration. Dependent on the design, a relative gain of the implant stiffness ranging from 18.8% to 115.0% could be observed. The large inverse-dynamisation implants revealed bending stiffnesses from 3.7Nm2 to 7.1Nm2 before and 4.1Nm2 to 12.6Nm2 after triggering the shape memory effect. Dependent on the design a gain in stiffness from 11.8% to 117.2% was observed. Warming the SMA implant to 40°C for a short period of time, leads to a moderate increase in implant stiffness of up to 64.5%, while triggering the implant with 50°C leads to a maximum increase in stiffness of up to 127.3%. The Nitinol shape memory bone plates have a huge potential for improving the treatment of long shaft fractures by allowing for the increase, decrease or incremental change of implant stiffness in fracture stabilization. However, the interaction between design, material properties, and manufacturing processes need to be carefully considered for each specific application to achieve optimum function of SMA-based, stiffness altering, fracture-fixation implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone fractures and treatments · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Mechanics and mechano-biology of fracture healing in normal and osteoporotic bone10.1007/s00198-004-1728-9 ↗
2. Early dynamization by reduced fixation stiffness does not improve fracture healing in a rat femoral osteotomy model10.1002/jor.20712 ↗
3. A nickel-titanium shape memory alloy plate for contactless inverse dynamization after internal fixation in a sheep tibia fracture model: a pilot study
4. Effects of static fixation and dynamization after interlocking femoral nailing locked with an external fixator: an experimental study in dogs10.1111/j.1532-950X.2004.04047.x ↗
5. The cell and molecular biology of fracture healing10.1097/00003086-199810001-00003 ↗
6. Timely fracture-healing requires optimization of axial fixation stability10.2106/00004623-200707000-00022 ↗
7. The influence of cyclic compression and distraction on the healing of experimental tibial fractures10.1016/j.orthres.2003.11.007 ↗
8. Effects of internal stress and martensite variants on phase transformation of NiTi shape memory alloy10.1023/A:1006682226289 ↗
9. The initial phase of fracture healing is specifically sensitive to mechanical conditions10.1016/S0736-0266(02)00259-0 ↗
10. Initial vascularization and tissue differentiation are influenced by fixation stability10.1016/j.orthres.2004.09.006 ↗
11. Mencík · 2013 · 42
12. Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications10.1016/j.actbio.2009.12.048 ↗
13. Electromagnetic induction heating of an orthopaedic nickel–titanium shape memory device10.1002/jor.21171 ↗
14. Transcutaneous electromagnetic induction heating of an intramedullary nickel–titanium shape memory implant10.1007/s00264-014-2460-5 ↗
15. Memory plate osteosynthesis for noninvasive modulation of fixation stiffness in a rabbit tibia osteotomy model10.1155/2015/652940 ↗
16. A preliminary study of bending stiffness alteration in shape changing nitinol plates for fracture fixation10.1007/s10439-011-0257-x ↗
17. Evolution of the internal fixation of long bone fractures the scientific basis of biological internal fixation: choosing a new balance between stability and biology10.1302/0301-620X.84B8.0841093 ↗
18. Noninvasive induction implant heating: an approach for contactless altering of mechanical properties of shape memory implants10.1016/j.medengphy.2012.03.010 ↗
19. The course of bone healing is influenced by the initial shear fixation stability10.1016/j.orthres.2005.03.005 ↗
20. A model for intramembranous ossification during fracture healing10.1016/S0736-0266(02)00017-7 ↗
21. Interlocking nail for femoral shaft fractures: is dynamization always necessary?10.1007/s00264-004-0627-1 ↗
22. Van Humbeeck, J., Stalmans, R., 2002. Shape memory alloys, types and functionalities. In: Encycl. Smart Mater., John Wiley & Sons, Inc. 〈http://onlinelibrary.wiley.com/doi/10.1002/0471216275.esm073/abstract〉, (Accessed 24 November 2015).10.1002/0471216275.esm073 ↗