journal article·2012-10

Roughness evolution of metallic implant surfaces under contact loading and nanometer-scale chemical etching

J.J. Ryu, S. Letchuman, P. Shrotriya

Publisher page

Abstract

Surface damage of metallic implant surface at taper lock and clamped interfaces may take place through synergistic interactions between repeated contact loading and corrosion. In the present research, we investigated the influence of surface roughness and contact loading on the mechanical and chemical damage phenomena. Cobalt-chromium (CoCrMo) specimens with two different roughness configurations created by milling and grinding process were subjected to normal and inclined contact loading. During repeated contact loading, amplitude of surface roughness reached a steady value after decreasing during the first few cycles. During the second phase, the alternating experiment of rough surface contact and micro-etching was conducted to characterize surface evolution behavior. As a result, surface roughness amplitude continuously evolved-decreasing during contact loading due to plastic deformation of contacting asperities and increasing on exposure to corrosive environment by the preferential corrosion attack on stressed area. Two different instabilities could be identified in the surface roughness evolution during etching of contact loaded surfaces: increase in the amplitude of dominant wavenumber and increase in amplitude of a small group of roughness modes. A damage mechanism that incorporates contact-induced residual stress development and stress-assisted dissolution is proposed to elucidate the measured instabilities in surface roughness evolution.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced machining processes and optimization · Adhesion, Friction, and Surface Interactions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (41)

Show source-provided references
2. A tribo-electrochemical apparatus for in vitro investigation of fretting-corrosion of metallic implant materials10.1016/S0043-1648(02)00027-3 ↗
3. Influence of fretting regimes on the tribocorrosion behaviour of Ti6Al4V in 0.9wt% sodium chloride solution10.1016/j.wear.2003.11.003 ↗
4. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution10.1016/j.wear.2004.12.012 ↗
5. Kinetically driven growth instability in stressed solids10.1103/PhysRevLett.81.1445 ↗
6. Corrosion and other electrochemical aspects of biomaterials
7. Stress-enhanced ion release—the effect of static loading10.1016/0142-9612(91)90108-M ↗
8. Analysis and convenient formulas for elasto-plastic contacts of nominally flat surfaces: average gap, contact area ratio and plastically deformed volume10.1007/s11249-007-9244-7 ↗
9. Fretting–corrosion behavior of beta titanium alloys in simulated synovial fluid10.1016/j.wear.2011.05.010 ↗
10. Tribo-electrochemical characterization of metallic biomaterials for total joint replacement10.1016/j.actbio.2011.09.034 ↗
11. An analytical expression for the stress field around an elastoplastic indentation/contact10.1016/j.actamat.2006.12.030 ↗
12. A quantitative analysis for the stress field around an elastoplastic indentation/contact10.1557/jmr.2009.0097 ↗
13. Fraker, A.C., 1987. Corrosion of metallic implants and prosthetic devices. In: Fraker, A.C., (Ed.), Materials handbook, Ninth ed. ASM International, vol. 13, pp. 1324–1335.
14. Generalized fractal analysis and its applications to engineering surfaces10.1016/0043-1648(94)06545-4 ↗
15. The behavior of an elastic-perfectly plastic sinusoidal surface under contact loading10.1016/j.wear.2005.09.016 ↗
16. The mechanical and electrochemical processes associated with taper fretting crevice corrosion: a review10.1520/STP12020S ↗
17. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling10.1002/jbm.820271210 ↗
18. A multicenter retrieval study of the taper interfaces of modular hip prostheses10.1097/00003086-200208000-00018 ↗
19. Orthopedic implant fretting corrosion10.1515/CORRREV.2003.21.2-3.183 ↗
20. Differences in the fretting corrosion of metal–metal and ceramic–metal modular junctions of total hip replacements10.1016/S0736-0266(03)00186-4 ↗
21. Elastoplastic indentation of a half-space by a rigid sphere10.1002/nme.1620030402 ↗
22. Effect of C content on the mechanical properties of solution treated as-cast ASTM F-75 alloys
23. Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys10.1007/s10856-010-4224-0 ↗
24. Corrosion of metal orthopaedic implants
25. Metal-on-metal bearing surfaces10.5435/00124635-200902000-00003 ↗
26. Static mechanical-properties of cast and sinter-annealed cobalt–chromium surgical implants10.1007/BF00553274 ↗
27. Evolution of a surface-roughness spectrum caused by stress in nanometer-scale chemical etching10.1103/PhysRevLett.83.3872 ↗
28. Fractal characterization and simulation of rough surfaces10.1016/0043-1648(90)90154-3 ↗
29. Construction of a tribocorrosion test apparatus for the hip joint: validation, test methodology and analysis10.1016/j.wear.2011.01.085 ↗
30. Mischler, S., 2003. Electrochemical control of wear: a third body approach. Tribological Research and Design for Engineering Systems, ed. D.P.M.D.G.L.A.A. Dowson. pp. 47–56.10.1016/S0167-8922(03)80118-9 ↗
31. Triboelectrochemical techniques and interpretation methods in tribocorrosion: a comparative evaluation10.1016/j.triboint.2007.11.003 ↗
32. Mitchell, A., Shrotriya, P., 2006. Stress Assisted Dissolution of Biomedical Grade CoCrMo: Influence of Contact Loads and Residual Stresses.
33. Average stress in matrix and average elastic energy of materals with misfitting inclusions10.1016/0001-6160(73)90064-3 ↗
34. Onset of surface damage in modular orthopedic implants: influence of normal contact loading and stress-assisted dissolution10.1007/s11340-006-9028-2 ↗
35. An approximate distribution of estimates of variance components10.2307/3002019 ↗
36. The role of fretting damage in total hip arthroplasty with modular design hip joints—evaluation of retrieval studies and experimental simulation methods
37. A new approach to plasticity and its application to blunt two dimensional indenters10.1115/1.3427785 ↗
38. The problem of comparing the results of two experiments with unequal errors
39. Tabor · 1951
40. Elastic stress field caused by indenting brittle materials10.1080/01418618208236917 ↗
41. Stress-dependent surface reactions and implications for a stress measurement technique10.1063/1.371999 ↗