Custom Morse taper zirconia abutments: Influence on marginal fit and torque loss before and after thermomechanical cycling
Source abstract
Abstract
The use of zirconia abutments has increased because of aesthetics, but sometimes customization is necessary and its effect is unclear. This study evaluated the marginal fit and torque loss of customized and non-customized aesthetic zirconia abutments associated with Morse taper implants before and after thermomechanical cycling. Twenty-four implant/abutment/crown sets were divided into three groups (N = 8): Zr - non-customized zirconia abutments, Zrc - customized zirconia abutments, and Ti - titanium abutments. The ceramic crowns of the upper canines were made. All of the abutments were tightened with 15-N.cm torque, and the crowns were cemented on the abutments. The misfits and torque loss were measured before and after thermomechanical cycling. The marginal fit was evaluated in two planes throughout 10 different slices, 30 measurements for each face (i.e., buccal, palatal, mesial and distal) and 120 measurements for each sample. A load of 100N, a frequency of 2Hz and 1000,000 cycles with temperature variation of 5°-55°C were used for thermomechanical cycling. Thermomechanical cycling significantly decreased the marginal misfit only with the Zrc (p = 0.002), and the Ti was significantly different from the Zr and Zrc before and after thermomechanical cycling. Thermomechanical cycling did not affect the torque losses of the groups, but a significant difference between the Zr and Zrc (p = 0.0345) before cycling was noted. Customization of zirconia abutments does not significantly affect torque loss and marginal misfit after thermomechanical cycling suggesting that they can be safe for clinical utilization.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. A comparison of precision of fit, rotational freedom, and torque loss with copy-milled zirconia and prefabricated titanium abutments10.11607/jomi.2937 ↗
2. Fracture Strength of zirconia implants after artificial aging10.1111/j.1708-8208.2008.00105.x ↗
3. Outcome analysis of implant restorations located in the anterior maxilla: a review of the recent literature
4. Precision of fit: zirconia three-unit fixed dental prostheses10.1007/s00784-008-0224-6 ↗
5. Bickford · 1995
6. Adaptation of all-ceramic fixed partial dentures10.1016/j.dental.2011.08.004 ↗
7. Esthetic option for the implant- supported single-tooth restoration – treatment sequence with a ceramic abutment
8. Mechanics of the tapered interference fit dental implants10.1016/S0021-9290(03)00177-5 ↗
9. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants10.1016/j.jbiomech.2004.03.006 ↗
10. Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique10.4103/1305-7456.143612 ↗
11. Marginal and internal fit of CAD-CAM-fabricated composite resina and cerâmica crowns scanner by intraoral cameras10.1016/j.prosdent.2016.07.017 ↗
12. Evaluation of the ITI Morse-taper implant/abutment design with an internal modification
13. Measurement of the rotational misfit and implant-abutment gap of allceramic abutments
14. Load fatigue performance of cônica implant-abutment connection: effect of torque level and interface junction
15. Cyclic loading of implant-supported prostheses: changes in component fit over time10.1067/mpr.2003.71 ↗
16. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup
17. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling10.11607/jomi.2727 ↗
18. Clinical methods for evaluating implant framework fit10.1016/S0022-3913(99)70229-5 ↗
19. Fatigue resistance of two implant/abutment joint designs10.1067/mpr.2002.129384 ↗
20. Screw loosening with interchangeable abutments in internally connect implants after cyclic loading
21. A comparativo study of marginal fit of copings prepared with various techgniques of different implant abutments10.4012/dmj.2015-252 ↗
22. Marginal vertical discrepancies of monolithic and veneered zirconia and metal-ceramic three-unit posterior fixed dental prostheses10.11607/ijp.4541 ↗
23. McCullagh · 1989
24. Torque loss of different abutment sizes before and after cyclic loading10.11607/jomi.3868 ↗
25. Bendind moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging10.1111/clr.12192 ↗
26. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems10.1016/S0022-3913(99)70243-X ↗
27. The effect of pressure on a maximum incisal bite force in man10.1016/S0003-9969(96)00106-9 ↗
28. Evaluation of marginal fit of single implant-supported metal cerâmic a crowns prepared by usinag presintered metal blocks
29. Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings
30. Fatigue resistance of ITI implant-abutment connectors-acomparison of the standard cone with a novel internally keyed design10.1034/j.1600-0501.2002.130515.x ↗
31. Effect of mechanical loading on the removal torque of different types tapered connection abutments for dental implants10.1016/j.prosdent.2013.06.007 ↗
32. Range of indications for translucent zirconia modifications: clinical and technical aspects
33. A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions10.1111/j.1600-0501.2009.01787.x ↗
34. Seo, D., Yi, Y., Roh, B., 2009. The Effect of Preparation Design on the Marginal and Internal Gaps in Cerec3 Partial Ceramic Crowns, 37, pp. 374–382.10.1016/j.jdent.2009.01.008 ↗
35. Fracture resistance of yttrium oxide partially-stabilized zirconia all-ceramic bridges after veneering and mechanical fatigue testing10.1016/j.dental.2004.07.013 ↗
36. An in vitro evaluation of titanium, zirconia, and alumina procera abutments with hexagonal connection
37. New prosthetic restorative features of The Ankylos implant system10.1563/1548-1336(2004)30<178:NPRFOT>2.0.CO;2 ↗
38. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone10.1034/j.1600-0501.1999.100601.x ↗
39. Effect of repeated closures and opening torque values in seven abutment-implant systems10.1067/mpr.2000.108069 ↗
40. In vivo fracture resistance of implant-supported all-ceramic restorations10.1016/S0022-3913(03)00514-6 ↗
41. Longitudinal data analysis using generalized linear models10.1093/biomet/73.1.13 ↗