A phospholipid polymer graft layer affords high resistance for wear and oxidation under load bearing conditions
Source abstract
Abstract
Manipulating the surface and substrate of cross-linked polyethylene (CLPE) is an essential approach for obtaining life-long orthopedic bearings. We therefore proposed a bearing material comprised of an antioxidative substrate generated by vitamin E blending (HD-CLPE[VE]) with a poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted surface, and investigated its wear resistance and oxidative stability under accelerated aging and load bearing conditions. Neither the hydration nor friction kinetics of the molecular network structure of the PMPC-grafted surface or the HD-CLPE(VE) substrate were influenced by accelerated aging but rather exhibited high stability even under high oxidation conditions. The characteristics of the PMPC-grafted surface improved the wear and impact fatigue resistance of the HD-CLPE(VE) liner regardless of accelerated aging. Notably, the PMPC-grafted surface was found to affect the potential oxidative stability at the rim part of the acetabular liner. PMPC chains serve several important functions on the surface regardless of load bearing, such as high lubricity or low lipophilicity attributed to phosphorylcholine groups and/or surrounding water-fluid film, and suppression of lipid diffusion attributed to methacrylate main chains on the surface. Together, these results provide preliminary evidence that the PMPC graft layer and vitamin E-blended substrate might positively affect the extent of orthopedic implant durability.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. In vitro wear performance of standard, crosslinked, and vitamin-E-blended UHMWPE10.1002/jbm.a.33297 ↗
2. Analysis of wear, wear particles, and reduced inflammatory potential of vitamin E ultrahigh-molecular-weight polyethylene for use in total joint replacement10.1002/jbm.b.32904 ↗
3. The epidemiology of revision total hip arthroplasty in the United States10.2106/JBJS.H.00155 ↗
4. Comparative epidemiology of revision arthroplasty: failed THA poses greater clinical and economic burdens than failed TKA10.1007/s11999-014-4078-8 ↗
5. Vitamin E-stabilized UHMWPE for total joint implants: a review10.1007/s11999-010-1717-6 ↗
6. Radiation-induced crosslinking of UHMWPE in the presence of co-agents: chemical and mechanical characterisation10.1016/j.polymer.2005.08.095 ↗
7. Effects of vitamin E-diffused highly cross-linked UHMWPE particles on inflammation, apoptosis and immune response against S. aureus10.1016/j.biomaterials.2017.07.028 ↗
8. Mechanisms of cross-linking, oxidative degradation, and stabilization of UHMWPE
9. Analysis of products diffused into UHMWPE prosthetic components in vivo10.1016/S0142-9612(00)00182-4 ↗
10. Boundary lubricants with exceptionally low friction coefficients based on 2D close-packed phosphatidylcholine liposomes10.1002/adma.201101053 ↗
11. Graves S., Turner C., 2016. Australian Orthopaedic Association National Joint Replacement Registry, Annual Report, Australian Orthopaedic Association, Adelaide.
12. Late failure of annealed highly cross-linked polyethylene acetabular liner10.1016/j.jmbbm.2013.08.003 ↗
13. The problem is osteolysis
14. The morphology and composition of the superficial zone of mammalian articular cartilage
15. Interlaboratory reproducibility of standard accelerated aging methods for oxidation of UHMWPE10.1016/S0142-9612(00)00333-1 ↗
16. Retrieval analysis of sequentially annealed highly crosslinked polyethylene used in total hip arthroplasty10.1007/s11999-014-4113-9 ↗
17. Effect of 2-methacryloyloxyethyl phosphorylcholine concentration on photo-induced graft polymerization of polyethylene in reducing the wear of orthopaedic bearing surface10.1002/jbm.a.31511 ↗
18. Enhanced wear resistance of orthopaedic bearing due to the cross-linking of poly(MPC) graft chains induced by gamma-ray irradiation10.1002/jbm.b.30874 ↗
19. Biomimetic hydration lubrication with various polyelectrolyte layers on cross-linked polyethylene orthopedic bearing materials10.1016/j.biomaterials.2012.03.028 ↗
20. Poly(2-methacryloyloxyethyl phosphorylcholine) grafting and vitamin E blending for high wear resistance and oxidative stability of orthopedic bearings10.1016/j.biomaterials.2014.04.051 ↗
21. Effect of UV-irradiation intensity on graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on orthopedic bearing substrate10.1002/jbm.a.34973 ↗
22. Prevention of bacterial adhesion and biofilm formation on a vitamin E-blended, cross-linked polyethylene surface with a poly(2-methacryloyloxyethyl phosphorylcholine) layer10.1016/j.actbio.2015.05.034 ↗
23. Multidirectional wear and impact-to-wear tests of phospholipid-polymer-grafted and vitamin E-blended crosslinked polyethylene: a pilot study10.1007/s11999-014-3995-x ↗
24. A hydrated phospholipid polymer-grafted layer prevents lipid-related oxidative degradation of cross-linked polyethylene10.1016/j.biomaterials.2016.10.021 ↗
25. Failure analysis of retrieved PE-UHMW acetabular liners10.1016/j.jmbbm.2016.01.007 ↗
26. A study of the thermal degradation of methyl methacrylate polymers and copolymers by thermal volatilization analysis10.1016/0014-3057(68)90004-9 ↗
27. Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis10.1038/nmat1233 ↗
28. Long-term hip simulator testing of the artificial hip joint bearing surface grafted with biocompatible phospholipid polymer10.1002/jor.22526 ↗
29. Clinical safety and wear resistance of the phospholipid polymer-grafted highly cross-linked polyethylene liner10.1002/jor.23473 ↗
30. A new mechanism of oxidation in ultrahigh molecular weight polyethylene caused by squalene absorption10.1002/jbm.b.32507 ↗
31. Surface cross-linked UHMWPE can enable the use of larger femoral heads in total joints10.1002/jor.22195 ↗
32. Increasing irradiation temperature maximizes vitamin E grafting and wear resistance of ultrahigh molecular weight polyethylene10.1002/jbm.b.32807 ↗
33. Stabilizing effect of oxygen on thermal degradation of poly (methyl methacrylate)10.1002/(SICI)1521-3927(19990901)20:9<480::AID-MARC480>3.0.CO;2-7 ↗
34. Irradiation of chemically crosslinked ultrahigh molecular weight polyethylene10.1002/(SICI)1099-0488(19960430)34:6<1063::AID-POLB4>3.0.CO;2-Z ↗
35. Surface depth analysis for fluorinated block copolymer films by X-ray photoelectron spectroscopy using C60 cluster ion beam10.1016/j.apsusc.2008.02.089 ↗
36. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators10.1002/jbm.a.30824 ↗
37. Influences of dehydration and rehydration on the lubrication properties of phospholipid polymer-grafted cross-linked polyethylene10.1177/0954411915588969 ↗