In-Vivo response to a novel pillared surface morphology for osseointegration in an ovine model
Source abstract
Abstract
Primary stability and secondary fixation of orthopedic implants to bony tissues are important for healing and long-term functionality. Load sharing and stress transfer are key requirements of an effective implant/tissue interface. This paper presents a novel, macro-scale osseointegration surface morphology which addresses the implant/tissue interface from both the biologic as well as biomechanical perspective. The surface morphology is a controlled, engineered, open topography manifested as discrete pillars projecting from the implant enabling continuous bone ingrowth. The pillared surface is distinct from other porous surfaces and can be differentiated by the localization of the implant material into discrete pillars enabling a continuous mass of bone to freely and easily interdigitate into the pillared structure. Traditional porous structures distribute the implant material throughout the surface forcing the bone to grow in a discontinuous manner. Creating an open and continuous space or "open porosity" in and around the pillar structure allows the bone to easily interdigitate with the implant surface without encumberment from a continuous porous structure. An in-vivo study, using an established ovine model, was undertaken examining the effects of pillar morphology on bone ingrowth and mechanical performance. Cortical and cancellous sites were evaluated utilizing histology, histomophometry, and mechanical pushout, at 4 and 12 weeks. Robust bone ingrowth occurred for all morphologies as was noted in review of the study results. An increase in volume and maturity of bone was noted between the intermediated and final time points. Histomophometry demonstrated over 40% and 80% new bone occupied the available "ingrowth" area at 12 weeks for cancellous and cortical sites (respectively). Histologic review showed little fibrous tissue ingrowth at the interface with no adverse cellular reactions. Testing of cortical samples demonstrated a significant increase in pushout load between the 4 and 12 week timepoints and a 4-8 fold increase in pushout load as compared to the grit blast control. These results demonstrated the effectiveness of the novel interface for orthopedic applications in an in-vivo ovine model.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · 3D Printing in Biomedical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies
2. Survivorship analysis at 15 Years of cemented press-fit condylar total knee arthroplasty10.1016/j.arth.2007.02.012 ↗
3. Long-term followup of the miller-galante total knee replacement10.1097/00003086-200107000-00010 ↗
4. Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium10.1016/j.arth.2010.12.007 ↗
5. Influence of Electron beam melting manufactured implants on ingrowth and shear strength in an ovine model10.1016/j.arth.2012.02.025 ↗
6. Osseointegration of multiphase Anodic spark deposition treated porous titanium implants in an ovine model10.1016/j.arth.2013.10.003 ↗
7. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial10.1302/0301-620X.81B5.0810907 ↗
8. In-vivo response to a discrete, marco-scale surface morphology enabling continuous bony in- growth: effects of surface variations and implant material composition
9. Results of in-vivo testing of a novel macro-scale osseointegration surface morphology
10. Effects of materials on osseointegration into a novel macro scale surface morphology
11. Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model
12. Does hydroxyapatite coating have no advantage over porous coating in primary total hip arthroplasty? A meta-analysis
13. A finite element analysis of the push-out test: influence of test conditions10.1002/jbm.820260111 ↗
14. Hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta-analysis10.1016/j.arth.2008.01.299 ↗
15. Recent advances in nanotubes for orthopedic implants
16. The effects of combined micron-submicron-scale surface roughness and nanoscale features on cell proliferation and differentiation10.1016/j.biomaterials.2011.01.029 ↗
17. Implant osseointegration and the role of microroughness and nanostructures: lessons for spine implants10.1016/j.actbio.2014.03.037 ↗
18. The problem is osteolysis
19. Wear and periprosthetic osteolysis: the problem10.1097/00003086-200112000-00007 ↗
20. Uncemented porous tantalum acetabular components: early follow-up and failures in 599 revision total hip arthroplasties
21. Hallmarks IN the history OF orthopaedic implants for trauma and joint replacement
22. A monoblock porous tantalum acetabular cup has No osteolysis on CT at 10 years10.1007/s11999-010-1500-8 ↗
23. Long-term implant survivorship of cementless total knee arthroplasty: a systematic review of the literature and meta-analysis
24. Hydroxyapatite-coating on titanium arc sprayed titanium implants10.1002/(SICI)1097-4636(19970605)35:3<287::AID-JBM3>3.0.CO;2-D ↗
25. Total knee arthroplasty with an uncemented trabecular metal tibial component: a registry-based analysis10.1016/j.arth.2013.04.014 ↗
26. Uncemented porous tantalum acetabular components: early follow-up and failures in 613 primary total hip arthroplasties10.1016/j.arth.2013.07.037 ↗
27. An introduction to controlled surface morphologies and the hard tissue response
28. In vivo osseointegration of a randomized trabecular titanium structure obtained by an additive manufacturing technique10.1007/s10856-019-6357-0 ↗
29. Factors affecting the durability of primary total knee prostheses10.2106/00004623-200302000-00012 ↗
30. The Anatomical Graduated Component total knee replacement: a long-term evaluation with 20-year survival analysis10.1302/0301-620X.91B6.21854 ↗
31. Spine implant surface technology state of the art, separating fact from fiction10.1097/BRS.0000000000002549 ↗
32. Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures10.1002/(SICI)1097-4636(200007)51:1<15::AID-JBM3>3.0.CO;2-9 ↗
33. The effect of substrate roughness and hydroxyapatite coating thickness on implant shear strength10.1054/arth.2002.30410 ↗
34. No effect of a type I collagen gel coating in uncemented implant fixation10.1002/jbm.b.30256 ↗
35. Midterm results of a porous tantalum monoblock tibia component: clinical and radiographic results of 108 knees10.1016/j.arth.2010.08.017 ↗
36. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface10.1016/j.spinee.2014.12.018 ↗
37. Does PEEK/HA enhance bone formation compared with PEEK in a sheep cervical fusion model?10.1007/s11999-016-4994-x ↗
38. Osseointegration of novel macro-structured surface
39. The in vivo response to a novel Ti coating compared to PEEK: evaluation of the periphery and inner surfaces of an implant10.1016/j.spinee.2018.02.017 ↗
40. Walsh · 2020 · vol. 15
41. Performance of porous tantalum vs. Titanium cup in total hip arthroplasty: randomized trial with minimum 10-year follow-up10.1016/j.arth.2015.01.013 ↗