journal article·2015-11

Mechanical characterization and modelling of the temperature-dependent impact behaviour of a biocompatible poly(L-lactide)/poly(ε-caprolactone) polymer blend

Gustaf Gustafsson, Masahiro Nishida, Yoshitaka Ito, Hans-Åke Häggblad, Pär Jonsén, Tetsuo Takayama, Mitsugu Todo

Publisher page

Abstract

Poly(ε-caprolactone) (PCL) is a ductile, bioabsorbable polymer that has been employed as a blend partner for poly(L-lactic acid) (PLLA). An improvement of the material strength and impact resistance of PLLA/PCL polymer blends compared to pure PLLA has been shown previously. To use numerical simulations in the design process of new components composed of the PLLA/PCL blend, a constitutive model for the material has to be established. In this work, a constitutive model for a PLLA/PCL polymer blend is established from the results of compressive tests at high and low strain rates at three different temperatures, including the body temperature. Finite element simulations of the split Hopkinson pressure bar test using the established constitutive model are carried out under the same condition as the experiments. During the experiments, the changes in the diameter and thickness of the specimens are captured by a high-speed video camera. The accuracy of the numerical model is tested by comparing the simulation results, such as the stress, strain, thickness and diameter histories of the specimens, with those measured in the experiments. The numerical model is also validated against an impact test of non-homogenous strains and strain rates. The results of this study provide a validated numerical model for a PLLA/PCL polymer blend at strain rates of up to 1800 s(-1) in the temperature range between 22°C and 50°C.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: biodegradable polymer synthesis and properties · Bone Tissue Engineering Materials · Silicone and Siloxane Chemistry

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Preparation and characterization of biodegradable PLA polymeric blends10.1016/S0142-9612(02)00466-0 ↗
2. Chen · 2010
3. Cowper · 1957
4. Immiscible polymer blends of semicrystalline biocompatible components: thermal properties and phase morphology analysis of PLLA/PCL blends10.1016/S0032-3861(01)00269-5 ↗
5. Determination of stress–strain characteristics at very high strain rates10.1007/BF02320419 ↗
6. Thermo-mechanical properties of poly ε-caprolactone/poly l-lactic acid blends: addition of nalidixic acid and polyethylene glycol additives10.1016/j.jmbbm.2015.01.022 ↗
7. Gray IIIG.T., 2000. Classic Split Hopkinson Pressure Bar Testing, ASM Handbook, 8, Mechanical Testing and Evaluation. ASM, pp. 462–476.10.31399/asm.hb.v08.a0003296 ↗
8. An experimental assessment of friction effects in the split Hopkinson pressure bar using the ring compression test10.1016/j.ijimpeng.2006.09.003 ↗
9. Modification of poly(L-lactides) by blending: mechanical and hydrolytic behavior10.1002/macp.1996.021970427 ↗
10. Characterization of compressive deformation behavior of multi-layer porous composite materials for articular tissue engineering10.1007/s12206-012-0502-8 ↗
11. Carbon content effect on high-strain-rate tensile properties for carbon steels10.1016/S0734-743X(99)00050-0 ↗
12. Kawata K., Hashimoto S., Kurokawa K. and Kanayama N.,1979. A new testing method for the characterization of materials in high velocity tension, mechanical properties at high rates of strain. In: Harding J. (Ed.), Conference Series No. 47. Insititute of Physics, Bristol and London, pp. 71–80.
13. A study on reduction of friction in impact compressive test based on the split Hopkinson pressure bar method by using a hollow specimen10.4028/www.scientific.net/AMM.566.548 ↗
14. Biofibres, biodegradable polymers and biocomposites: an overview10.1002/(SICI)1439-2054(20000301)276:1<1::AID-MAME1>3.0.CO;2-W ↗
15. Modeling the response of nonlinear viscoelastic biodegradable polymeric stents10.1016/j.ijsolstr.2011.12.007 ↗
16. Strain rate dependence of compressive stress–strain loops of several polymers10.1299/jmmp.2.557 ↗
17. Evaluation of dynamic compressive properties of PLA polymer blends using split Hopkinson pressure bar
18. Norman · 1989 · 333
19. Siviour · Polymer · 2005 · 46 · 1254610.1016/j.polymer.2005.10.109 ↗
20. Improvement of impact fracture properties of PLA/PCL polymer blend due to LTI addition10.1007/s10853-006-0137-1 ↗
21. LS-DYNA, 2007, Keyword user׳s manual, vol. 1, version 971.
22. Effect of annealing on the mechanical properties of PLA/PCL and PLA/PCL/LTI polymer blends10.1016/j.jmbbm.2010.10.003 ↗
23. Effect of LTI Blending on Fracture Properties of PLA/PCL Polymer Blend10.1299/jmmp.1.1157 ↗
24. Fracture micromechanisms of bioabsorbable PLLA/PCL polymer blends10.1016/j.engfracmech.2006.05.021 ↗
25. Blends of Aliphatic Polyesters. I. Physical Properties and Morphologies of Solution-Cast Blends from Poly(DL-lactide) and Poly(epsilon-caprolactone)10.1002/(SICI)1097-4628(19960627)60:13<2367::AID-APP8>3.0.CO;2-C ↗
26. Blends of aliphatic polyesters: VII. Effects of poly(L-lactide-co-e-caprolactone) on morphology, structure, crystallization, and physical properties of blends of poly(L-lactide) and poly(e-caprolactone)10.1002/pi.1093 ↗
27. Considerations for the design of polymeric biodegradable products10.1515/polyeng-2012-0150 ↗