Monotonic and fatigue behavior of five clinically relevant conventional and highly crosslinked UHMWPEs in the presence of stress concentrations
Source abstract
Abstract
Five formulations of clinically relevant UHMWPE (conventional, moderately crosslinked annealed and remelted, and highly crosslinked annealed and remelted) were investigated in a physiologically relevant environment. Their monotonic stress-strain behavior in the presence of notches of two different severities and at two different displacement rates was examined using a custom developed video based system. It was found that both an elevation of yield stress and a truncation of orientation hardening took place under monotonic loading and that these changes were found to be material and elastic stress concentration factor dependent. The fatigue behavior of these materials was examined using the same geometries via a stress-life approach with failure defined as fracture of the specimen in the 1000 to 100,000 cycle lifetime range. The results were modeled using the Basquin relationship (σ=AN(b), where σ=stress and N=lifetime, and A and b are experimentally derived constants) via maximum likelihood estimation methods to account for specimen runout (no failure at 250,000cycles). The conventional material was found to have a greater slope, b, and intercept, A, than the crosslinked materials as well as appearing to have less variance in its failure distributions.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene10.1016/j.jmbbm.2011.03.012 ↗
2. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene10.1002/jbm.a.10606 ↗
3. Collins · 1993
4. Dowling · 1999
5. Highly crosslinked polyethylene is safe for use in total knee arthroplasty10.1007/s11999-008-0472-4 ↗
6. The role of macrophages in osteolysis of total joint replacement10.1016/j.biomaterials.2004.04.035 ↗
7. Karian · 2003
8. 2009
9. Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements10.1016/S0142-9612(02)00102-3 ↗
10. Projections of primary and revision hip and knee arthroplasties in the United States from 2005 to 2030
11. Lawless · 2003
12. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacement10.1002/jor.1100170203 ↗
13. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene
14. Comparative fatigue behavior and toughness of remelted and annealed highly crosslinked polyethylenes10.1002/jbm.b.30807 ↗
15. Comparison between highly cross-linked and conventional polyethylene in total knee arthroplasty10.1016/j.knee.2009.01.005 ↗
16. A note on a general definition of the coefficient of determination10.1093/biomet/78.3.691 ↗
17. Musculoskeletal conditions in the United States
18. Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene10.1016/j.biomaterials.2004.03.022 ↗
19. Influence of the remelting process on the fatigue behavior of electron beam irradiated UHMWPE10.1002/jbm.b.30378 ↗
20. No adjustments are needed for multiple comparisons10.1097/00001648-199001000-00010 ↗
21. Runout analysis in fatigue investigation10.1016/j.engfracmech.2006.08.026 ↗
22. Multiple comparison procedures: the practical solution10.1080/00031305.1990.10475712 ↗
23. Interaction of oxidation and crosslinking in gamma-irradiated ultrahigh molecular weight polyethylene10.1002/jbm.10203 ↗
24. Notch strengthening and hardening behavior of conventional and highly crosslinked UHMWPE under applied tensile loading10.1016/j.biomaterials.2004.09.031 ↗
25. Notched stress-strain behavior of a conventional and a sequentially annealed highly crosslinked UHMWPE10.1016/j.biomaterials.2008.08.010 ↗
26. Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior10.1016/j.jmbbm.2008.12.006 ↗
27. Development and application of the notched tensile test to UHMWPE