Finite element simulation of Reference Point Indentation on bone
Source abstract
Abstract
Reference Point Indentation (RPI) is a novel technique aimed to assess bone quality. Measurements are recorded by the BioDent instrument that applies multiple indents to the same location of cortical bone. Ten RPI parameters are obtained from the resulting force-displacement curves. Using the commercial finite element analysis software Abaqus, we assess the significance of the RPI parameters. We create an axisymmetric model and employ an isotropic viscoelastic-plastic constitutive relation with damage to simulate indentations on a human cortical bone. Fracture of bone tissue is not simulated for simplicity. The RPI outputs are computed for different simulated test cases and then compared with experimental results, measured using the BioDent, found in literature. The number of cycles, maximum indentation load, indenter tip radius, and the mechanical properties of bone: Young׳s modulus, compressive yield stress, and viscosity and damage constants, are varied. The trends in the RPI parameters are then investigated. We find that the RPI parameters are sensitive to the mechanical properties of bone. An increase in Young׳s modulus of bone causes the force-displacement loading and unloading slopes to increase and the total indentation distance (TID) to decrease. The compressive yield stress is inversely proportional to a creep indentation distance (CID1) and the TID. The viscosity constant is proportional to the CID1 and an average of the energy dissipated (AvED). The maximum indentation load is proportional to the TID, CID1, loading and unloading slopes, and AvED. The damage parameter is proportional to the TID, but it is inversely proportional to both the loading and unloading slopes and the AvED. The value of an indenter tip radius is proportional to the CID1 and inversely proportional to the TID. The number of load cycles is inversely proportional to an average of a creep indentation depth (AvCID) and the AvED. The indentation distance increase (IDI) is strongly inversely proportional to the compressive yield stress, and strongly proportional to the viscosity constant and maximum applied load, but has weak relation with the damage parameter, indenter tip radius, and elastic modulus. This computational study advances our understanding of the RPI outputs and provides a starting point for more comprehensive computational studies of the RPI technique.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Metal and Thin Film Mechanics · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. ABAQUS V6.14 theory guide. 〈http://abaqus.software.polimi.it/v6.14/books/stm/default.htm〉
2. Multiscale predictors of femoral neck in situ strength in aging women: contributions of bmd, cortical porosity, reference point indentation, and nonenzymatic glycation10.1002/jbmr.2568 ↗
3. The effect of friction on indenter force and pile-up in numerical simulations of bone nanoindentation10.1016/j.jmbbm.2011.03.026 ↗
4. True gold or pyrite: a review of reference point indentation for assessing bone mechanical properties in vivo10.1002/jbmr.2603 ↗
5. In vivo reference point indentation reveals positive effects of raloxifene on mechanical properties following 6 months of treatment in skeletally mature beagle dogs10.1016/j.bone.2013.07.009 ↗
6. Multi-scale analysis of bone chemistry, morphology and mechanics in the OIM model of osteogenesis imperfecta10.3109/03008207.2014.923860 ↗
7. Characterization of damage mechanisms associated with reference point indentation in human bone."10.1016/j.bone.2015.01.019 ↗
8. Intervertebral discs from spinal nondeformity and deformity patients have different mechanical and matrix properties10.1016/j.spinee.2013.06.089 ↗
9. Variability in reference point microindentation and recommendations for testing cortical bone: Location, thickness and orientation heterogeneity10.1016/j.jmbbm.2015.02.004 ↗
10. Microindentation for in vivo measurement of bone tissue mechanical properties in humans10.1002/jbmr.73 ↗
11. In vivo assessment of bone quality in postmenopausal women with type 2 diabetes10.1002/jbmr.2106 ↗
12. Reference-point indentation correlates with bone toughness assessed using whole-bone traditional mechanical testing10.1016/j.bone.2012.12.015 ↗
13. Insights into reference point indentation involving human cortical bone: Sensitivity to tissue anisotropy and mechanical behavior10.1016/j.jmbbm.2014.05.016 ↗
14. Identifying novel clinical surrogates to assess human bone fracture toughness10.1002/jbmr.2452 ↗
15. Microindentation for in vivo measurement of bone tissue material properties in atypical femoral fracture patients and controls10.1002/jbmr.1731 ↗
16. Nanoscale changes in collagen are reflected in physical and mechanical properties of bone at the microscale in diabetic rats10.1016/j.bone.2013.11.015 ↗
17. The bone diagnostic instrument II: indentation distance increase10.1063/1.2937199 ↗
18. The tissue diagnostic instrument10.1063/1.3127602 ↗
19. Bone diagnostic instrument10.1063/1.2221506 ↗
20. Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation10.1016/j.jmbbm.2014.11.020 ↗
21. Toward high-speed 3D nonlinear soft tissue deformation simulations using Abaqus software10.1007/s11701-015-0531-2 ↗
22. Variability in reference point microindentation and recommendations for testing cortical bone: maximum load, sample orientation, mode of use, sample preparation and measurement spacing10.1016/j.jmbbm.2014.09.030 ↗
23. Toughness and damage susceptibility in human cortical bone is proportional to mechanical inhomogeneity at the osteonal-level10.1016/j.bone.2015.03.020 ↗
24. On the mechanistic origins of toughness in bone10.1146/annurev-matsci-070909-104427 ↗
25. A plastic-damage model for concrete10.1016/0020-7683(89)90050-4 ↗
26. Nano-structural, compositional and micro-architectural signs of cortical bone fragility at the superolateral femoral neck in elderly hip fracture patients vs. healthy aged controls10.1016/j.exger.2014.03.001 ↗
27. Calibration of a constitutive model for the post-yield behaviour of cortical bone10.1016/j.jmbbm.2008.11.003 ↗
28. The bone diagnostic instrument III: testing mouse femora10.1063/1.3147383 ↗
29. Reference point indentation study of age-related changes in porcine femoral cortical bone10.1016/j.jbiomech.2013.04.003 ↗
30. Modelling of bone fracture and strength at different length scales – a review10.1098/rsfs.2015.0055 ↗
31. Towards a standardized reference point indentation testing procedure10.1016/j.jmbbm.2014.01.012 ↗
32. In situ materials characterization using the tissue diagnostic instrument10.1016/j.polymertesting.2009.10.005 ↗
33. Local tissue properties of human osteoarthritic cartilage correlate with magnetic resonance T1rho relaxation times10.1002/jor.21381 ↗
34. The use of traditional and novel techniques to determine the hardness and indentation properties of immature radicular dentin treated with antibiotic medicaments followed by ethylenediaminetetraacetic acid10.4103/1305-7456.143636 ↗
35. Characterization of indentation response and stiffness reduction of bone using a continuum damage model10.1016/j.jmbbm.2009.08.001 ↗
36. Mechanical property determination of bone through nano- and micro-indentation testing and finite element simulation10.1016/j.jbiomech.2007.09.019 ↗