journal article·2021-02

Development of a micro-scale method to assess the effect of corrosion on the mechanical properties of a biodegradable Fe-316L stent material

Jennifer Frattolin, Emanuele Cattarinuzzi, Sriraman Rajagopalan, Dario Gastaldi, Pasquale Vena, Stephen Yue, Olivier F. Bertrand, Rosaire Mongrain

Publisher page

Abstract

The application of biodegradable materials to stent design has the potential to transform coronary artery disease treatment. It is critical that biodegradable stents have sustained strength during degradation and vessel healing to prevent re-occlusion. Proper assessment of the impact of corrosion on the mechanical behaviour of potential biomaterials is important. Investigations within literature frequently implement simplified testing conditions to understand this behaviour and fail to consider size effects associated with strut thickness, or the increase in corrosion due to blood flow, both of which can impact material properties. A protocol was developed that utilizes micro-scale specimens, in conjunction with dynamic degradation, to assess the effect of corrosion on the mechanical properties of a novel Fe-316L material. Dynamic degradation led to increased specimen corrosion, resulting in a greater reduction in strength after 48 h of degradation in comparison to samples statically corroded. It was found that thicker micro-tensile samples (h > 200 μm) had a greater loss of strength in comparison to its thinner counterpart (h < 200 μm), due to increased corrosion of the thicker samples (203 MPa versus 260 MPa after 48 h, p = 0.0017). This investigation emphasizes the necessity of implementing physiologically relevant testing conditions, including dynamic corrosion and stent strut thickness, when evaluating potential biomaterials for biodegradable stent application.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corrosion Behavior and Inhibition · Magnesium Alloys: Properties and Applications · Hydrogen embrittlement and corrosion behaviors in metals

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Corrosion and surface finishing
2. Champagne · 2007
3. Effect of roughness on electrochemical and pitting corrosion of Ti-6Al-4V alloy in 12 wt.% HCl solution at 35 °C10.1016/j.jmrt.2019.11.044 ↗
4. Update on in-stent restenosis
5. Effect of surface roughness on corrosion behaviour of low carbon steel in inhibited 4M hydrochloric acid under laminar and turbulent flow conditions10.1016/j.corsci.2015.11.019 ↗
6. Development of a novel biodegradable metallic stent based on microgalvanic effect10.1007/s10439-015-1458-5 ↗
7. Development of a novel biodegradable metallic stent based on microgalvanic effect10.1007/s10439-015-1458-5 ↗
8. A manufacturing and annealing protocol to develop a cold-sprayed Fe-316L stainless steel biodegradable stenting material10.1016/j.actbio.2019.08.034 ↗
9. A strain-mediated corrosion model for bioabsorbable metallic stents10.1016/j.actbio.2017.04.020 ↗
10. Size effects in miniaturized polycrystalline FCC samples: strengthening versus weakening10.1016/j.ijsolstr.2006.05.009 ↗
11. Influence of statistical size effects on the plastic deformation of coronary stents10.1016/j.jmbbm.2012.12.008 ↗
12. A novel flow chamber for biodegradable alloy assessment in physiologically realistic environments10.1063/1.4821498 ↗
13. A physical corrosion model for bioabsorbable metal stents10.1016/j.actbio.2013.12.059 ↗
14. A corrosion model for bioabsorbable metallic stents10.1016/j.actbio.2011.05.032 ↗
15. The effect of tensile and fluid shear stress on the in vitro degradation of magnesium alloy for stent applications
16. Statistical size effects based on grain size and texture in thin sheets10.1016/j.msea.2006.11.113 ↗
17. An experimental assessment of grain size effects in the uniaxial straining of thin Al sheet with a few grains across the thickness10.1016/j.msea.2005.12.029 ↗
18. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial10.1161/01.CIR.103.23.2816 ↗
19. Laser microprocessing of metallic stent for medical therapy10.1016/j.jmatprotec.2005.05.041 ↗
20. Microstructural size effects on mechanical properties of high purity nickel10.1016/j.ijplas.2010.08.002 ↗
21. The systems biocompatibility of coronary stenting
22. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials10.1016/j.actbio.2007.09.012 ↗
23. Experimental setup and realization of thin film specimens for microtensile tests10.1063/1.3077153 ↗
24. Accurate prediction of wall shear stress in a stented artery: Newtonian versus non-Newtonian models10.1115/1.4004408 ↗
25. Laser micro-processing of cardiovascular stent with fiber laser cutting system10.1016/j.optlastec.2008.06.001 ↗
26. Effect of specimen thickness on mechanical properties of polycrystalline aggregates with various grain sizes10.1016/0001-6160(79)90120-2 ↗
27. The stress-strain behavior of coronary stent struts is size dependent10.1114/1.1569268 ↗
28. The stress-strain behavior of coronary stent struts is size dependent10.1114/1.1569268 ↗
29. Özel · 2016
30. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial10.1016/S0735-1097(03)00119-0 ↗
31. The development of the cold spray process
32. Stable coronary artery disease: revascularisation and invasive strategies10.1016/S0140-6736(15)61220-X ↗
33. Four-year experience with Palmaz-Schatz stenting in coronary angioplasty complicated by dissection with threatened or present vessel closure10.1161/01.CIR.90.6.2716 ↗
34. 2012
35. 2016
36. Fabrication of a polymer-based biodegradable stent using a CO2 laser10.1016/j.acme.2013.08.005 ↗
37. The use of multiple pseudo-physiological solutions to simulate the degradation behavior of pure iron as a metallic resorbable implant: a surface-characterization study10.1039/C6CP02451C ↗
38. Flow-induced corrosion behavior of absorbable magnesium-based stents10.1016/j.actbio.2014.08.034 ↗
39. Flow-induced corrosion of absorbable magnesium alloy: in-situ and real-time electrochemical study10.1016/j.corsci.2015.12.020 ↗
40. Experimental data confirm numerical modeling of the degradation process of magnesium alloys stents10.1016/j.actbio.2012.10.035 ↗
41. Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis10.1007/s11517-009-0432-5 ↗
42. Research on an Mg–Zn alloy as a degradable biomaterial10.1016/j.actbio.2009.06.028 ↗
43. A review on in vitro corrosion performance test of biodegradable metallic materials10.1016/S1003-6326(13)62730-2 ↗