journal article·2021-05

Damage evaluation of HAp-coated porous titanium foam in simulated body fluid based on compression fatigue behavior

Munshi Mohammad Raihan, Yuichi Otsuka, Koudai Tsuchida, Anchalee Manonukul, Kiyoshi Ohnuma, Yukio Miyashita

Publisher page

Abstract

Although pure Ti is nontoxic, alloying elements may be released into the surrounding tissue when Ti alloys are used, and this can cause cytotoxicity. Therefore, this study performed the damage evaluation of hydroxyapatite (HAp)-coated porous Ti components subjected to cyclic compression in a simulated body fluid (SBF). The HAp coating layer was deposited on the surface of porous Ti by electrophoresis, and a dense and homogeneous coating morphology was observed on the surface of the porous Ti. To specify damage types of HAp coating in situ, acoustic emission (AE) measurements and microscopic observations were simultaneously conducted during compressive fatigue loading tests to detect the specific failure mode. Compression tests revealed that the interfacial strength between the HAp coating and porous Ti was higher than the yield strength of the porous body (7-9 MPa). The AE signals were detected only in the plastic deformation stage of porous Ti, which indicated that they were generated because of plastic deformation/fractures in the porous body. Compressive fatigue tests revealed that no significant HAp coating damage occurred when the applied maximum stress was within the elastic limit of porous Ti in air. In contrast, the HAp coating exhibited delamination at the initial stage of cyclic loading at all stress levels in SBF, while the fatigue limit of the coated porous substrate, 2 MPa, was not affected by the SBF medium. Though the delamination of the HAp coating in SBF occurred during the early stages of fatigue loading, the amorphous calcium phosphate layer was recovered partly through re-precipitation from SBF. The AE signals from the delamination of the HAp coating or fracture in porous Ti could be identified using the peak voltage and frequencies. As microscopic observations were limited to certain parts of the porous body, AE signals were clustered according to the types of failure. The clustered AE signals were successfully correlated with the fatigue behavior of porous Ti. Corrosion fatigue was determined to be the primary mechanism for the delamination of the HAp coating on porous Ti in SBF.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Bone Tissue Engineering Materials · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Influence of chitosan on the antibacterial activity of composite coating (peek/hap) fabricated by electrophoretic deposition10.1016/j.porgcoat.2019.01.050 ↗
2. Designing bioactive porous titanium interfaces to balance mechanical properties and in vitro cells behavior towards increased osseointegration10.1016/j.surfcoat.2019.03.001 ↗
3. Differentiation between hydroxyapatite and beta- tricalcium phosphate by means of Raman spectroscopy10.1016/S0955-2219(98)00057-0 ↗
4. Bioactive hydroxyapatite coatings on polymer composites for orthopedic implants10.1002/jbm.a.30284 ↗
5. Effects of applied stress ratio on the fatigue behavior of additively manufactured porous biomaterials under compressive loading10.1016/j.jmbbm.2016.11.022 ↗
6. Improvement of the balance between a reduced stress shielding and bone ingrowth by bioactive coatings onto porous titanium substrates10.1016/j.surfcoat.2018.01.019 ↗
7. Bioactive coatings on porous titanium for biomedical applications10.1016/j.surfcoat.2018.06.037 ↗
8. Mechanical behaviour of cp magnesium with duplex hydroxyapatite and peo coatings10.1016/j.msec.2014.12.081 ↗
9. The mechanical properties of human tibial trabecular bone as a function of metaphyseal location10.1016/0021-9290(83)90097-0 ↗
10. Calcium phosphate coatings: a comparative study between simultaneous vapor deposition and electron beam deposition techniques10.1016/j.surfcoat.2006.06.029 ↗
11. Axial suspension plasma spraying: an ultimate technique to tailor ti6al4v surface with hap for orthopaedic applications10.1016/j.colsurfb.2018.10.071 ↗
12. How does tissue regeneration influence the mechanical behavior of additively manufactured porous biomaterials?10.1016/j.jmbbm.2016.10.003 ↗
13. Fatigue crack propagation in additively manufactured porous biomaterials10.1016/j.msec.2017.03.091 ↗
14. Thermal spraying of biomaterials10.1016/j.surfcoat.2006.04.052 ↗
15. Electrochemical deposition and characterization of hydroxyapatite (hap) on titanium substrate10.1016/j.apcbee.2012.06.044 ↗
16. Porous titanium manufactured by a novel powder tapping method using spherical salt bead space holders: characterisation and mechanical properties10.1016/j.jmbbm.2015.04.018 ↗
17. How useful is sbf in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
18. Failure behavior of plasma-sprayed hap coating on commercially pure titanium substrate in simulated body fluid (sbf) under bending load10.1016/j.jmbbm.2012.05.017 ↗
19. Compression fatigue behavior and failure mechanism of porous titanium for biomedical applications10.1016/j.jmbbm.2016.09.035 ↗
20. Corrosion fatigue behavior of additively manufactured biodegradable porous iron10.1016/j.corsci.2019.05.003 ↗
21. Biodegradation-affected fatigue behavior of additively manufactured porous magnesium
22. Fatigue behavior of plasma sprayed structural-grade hydroxyapatite coating under simulated body fluids10.1016/j.surfcoat.2019.04.028 ↗
23. Corrosion fatigue behavior of additively manufactured biodegradable porous zinc10.1016/j.actbio.2020.02.001 ↗
24. Compressive and fatigue behavior of beta-type titanium porous structures fabricated by electron beam melting10.1016/j.actamat.2016.12.052 ↗
25. Enhanced fatigue characteristics of a topology-optimized porous titanium structure produced by selective laser melting
26. Fatigue and acoustic emission behavior of plasma sprayed hap top coat and hap/ti bond coat with hap top coat on commercially pure titanium
27. Fatigue behavior and apatite precipitation of plasma sprayed hap coating on commercially pure titanium substrate in simulated body fluid (sbf)
28. Biocompatibility of a new biodegradable polymer-hydroxyapatite composite for biomedical applications10.1016/j.jddst.2017.01.008 ↗
29. Microstructure and mechanical properties of commercially pure titanium foam with varied cell size fabricated by replica impregnation method10.1016/j.msea.2015.10.074 ↗
30. Geometry anisotropy and mechanical property isotropy in titanium foam fabricated by replica impregnation method10.1016/j.msea.2016.01.017 ↗
31. Fabrication and characterization of nanostructured hydroxyapatite coating on mg-based alloy by high-velocity oxygen fuel spraying10.1016/j.ceramint.2018.05.093 ↗
32. Influence of alloying elements on cellular response and in-vitro corrosion behavior of titanium-molybdenum-chromium alloys for implant materials10.1016/j.jpor.2020.01.004 ↗
33. Effect of mg concentration on interfacial strength and corrosion fatigue behavior of thermal-sprayed al-mg coating layers10.1016/j.engfailanal.2018.02.012 ↗
34. Bone mechanical properties in healthy and diseased states10.1146/annurev-bioeng-062117-121139 ↗
35. Effect of apatite precipitation on failure behavior of hydroxyapatite coating layer on titanium substrate
36. Effect of dissolution/precipitation on the residual stress redistribution of plasma-sprayed hydroxyapatite coating on titanium substrate in simulated body fluid (sbf)10.1016/j.jmbbm.2014.04.007 ↗
37. 6 - supplementary techniques including blood parasite diagnosis
38. Prediction of cyclic delamination lives of plasma-sprayed hydroxyapatite coating on ti–6al–4v substrates with considering wear and dissolutions10.1016/j.jmbbm.2016.07.026 ↗
39. Cyclic delamination behavior of plasma-sprayed hydroxyapatite coating on ti–6al–4v substrates in simulated body fluid10.1016/j.msec.2016.05.058 ↗
40. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders10.1016/j.msec.2015.11.050 ↗
41. Effects of pore size and porosity of surface-modified porous titanium implants on bone tissue ingrowth10.1016/S1003-6326(19)65161-7 ↗
42. Chapter 1 - natural bone tissue and its biomimetic
43. The effect of simulated body fluid on the mechanical properties of multiblock poly(aliphatic/aromatic-ester) copolymers10.1016/j.biomaterials.2003.12.021 ↗
44. Electrochemical behavior of polypyrrole/chitosan composite coating on ti metal for biomedical applications10.1016/j.carbpol.2018.01.042 ↗
45. Satoshi Kobayashi · 2007
46. Electrophoretic deposition of hydroxyapatite-iron oxide-chitosan composite coatings on ti–13nb–13zr alloy for biomedical applications10.1016/j.tsf.2020.137801 ↗
47. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: an in vivo experiment10.1016/j.msec.2015.10.069 ↗
48. Evaluation of channel-like porous-structured titanium in mechanical properties and osseointegration
49. Mechanical properties, electrochemical corrosion and in-vitro bioactivity of yttria stabilized zirconia reinforced hydroxyapatite coatings prepared by gas tunnel type plasma spraying10.1016/j.jmbbm.2011.11.002 ↗
50. The effect of osteoprotegerin gene modification on wear debris-induced osteolysis in a murine model of knee prosthesis failure10.1016/j.biomaterials.2009.07.032 ↗
51. Compressive and fatigue behavior of functionally graded ti-6al-4v meshes fabricated by electron beam melting10.1016/j.actamat.2018.02.060 ↗