A 3D-transient elastohydrodynamic lubrication hip implant model to compare ultra high molecular weight polyethylene with more compliant polycarbonate polyurethane acetabular cups

Audrey Ford, Zikai Hua, Stephen J. Ferguson, Lisa A. Pruitt, Leiming Gao

Publisher page

Abstract

Wear remains a significant challenge in the design of orthopedic implants such as total hip replacements. Early elastohydrodynamic lubrication modeling has predicted thicker lubrication films in hip replacement designs with compliant polycarbonate polyurethane (PCU) bearing materials compared to stiffer materials like ultra-high molecular weight polyethylene (UHMWPE). The predicted thicker lubrication films suggest improved friction and wear performance. However, when compared to the model predictions, experimental wear studies showed mixed results. The mismatch between the model and experimental results may lie in the simplifying assumptions of the early models such as: steady state conditions, one dimensional rotation and loading, and high viscosities. This study applies a 3D-transient elastohydrodynamic model based on an ISO standard gait cycle to better understand the interaction between material stiffness and film thickness in total hip arthroplasty material couples. Similar to previous, simplified models, we show that the average and central film thickness of PCU (∼0.4μm) is higher than that of UHMWPE (∼0.2μm). However, in the 3D-transient model, the film thickness distribution was largely asymmetric and the minimum film thickness occurred outside of the central axis. Although the overall film thickness of PCU was higher than UHMWPE, the minimum film thickness of PCU was lower than UHMPWE for the majority of the gait cycle. The minimum film thickness of PCU also had a larger range throughout the gait cycle. Both materials were found to be operating between boundary and mixed lubrication regimes. This 3D-transient model reveals a more nuanced interaction between bearing material stiffness and film thickness that supports the mixed results found in experimental wear studies of PCU hip implant designs.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene10.1016/j.jmbbm.2011.03.012 ↗
2. Cushion form bearing for total knee joint replacement part 1: design, friction and lubrication10.1243/PIME_PROC_1995_209_323_02 ↗
3. Assessment of the viscoelastic mechancial properties of polycarbonate urethane for medical devices10.1016/j.jmbbm.2018.02.015 ↗
4. Burger · 2009
5. A comparison of hemiarthroplasty with a novel polycarbonate-urethane acetabular component for displaced intracapsular fractures of the femoral neck
6. Design considerations for cushion form bearing in artificial hip joints10.1243/PIME_PROC_1991_205_269_02 ↗
7. Micro-elastohydrodynamic lubrication of synovial joints10.1243/EMED_JOUR_1986_015_019_02 ↗
8. Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints10.1016/j.actbio.2010.07.011 ↗
9. Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation10.1115/1.4001892 ↗
10. Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: A 20 million cycles wear simulation10.1002/jor.21471 ↗
11. Compliant layer knee bearings. Part II: Preliminary wear assessment10.1016/j.wear.2010.04.002 ↗
12. Micromechanisms of fatigue crack growth in polycarbonate polyurethane: time dependent and hydration effects10.1016/j.jmbbm.2018.01.008 ↗
13. Lubrication modelling of hip joint implants
14. A numerical study of non-Newtonian transient elastohydrodynamic lubrication of metal-on-metal hip prostheses10.1016/j.triboint.2015.03.003 ↗
15. Effect of walking patterns on the elastohydrodynamic lubrication of metal-on-metal total hip replacements10.1177/1350650110396802 ↗
16. Can a “pre-worn” bearing surface geometry reduce the wear of metal-on-metal hip replacements? – A numerical wear simulation study10.1016/j.wear.2018.03.010 ↗
17. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements10.1016/j.medengphy.2009.02.002 ↗
18. Determination of the mechanical properties of Bionate 80A and Bionate 75D for the stress analysis of cushion form bearings10.1243/09544119JEIM372 ↗
19. Prosthetic surgery in fragility ostopathy
20. Effects of orthopaedic wear particles on osteoprogenitor cells10.1016/j.biomaterials.2006.08.023 ↗
21. In vivo deformation, surface damage, and biostability of retrieved dynesys systems10.1097/BRS.0b013e3181d6f84f ↗
22. Wear particles
23. Elastohydrodynamic lubrication analysis of UHMWPE and hip joint replacements
24. Prediction of lubricating film thickness in UHMWPE hip joint replacements10.1016/S0021-9290(00)00181-0 ↗
25. Transient elastohydrodynamic lubrication analysis of and ultra-high molecular weight polyethylene hip joint and replacements10.1243/0954406021525205 ↗
26. Elastohydrodynamic lubrication analysis of hip implants with ultra high molecular weight polyethylene cups under transient conditions
27. Elastohydrodynamic lubrication in biological systems10.1243/135065005X33982 ↗
28. Wear and friction of medical grade polyurethane sliding on smooth metal counterfaces10.1016/0043-1648(93)90554-Y ↗
29. Measurement of lubricating film thickness in low elastic modulus lined bearings, with particular reference to models of cushion form bearings for total joint replacements: Part 1: steady state entraining motion10.1243/PIME_PROC_1994_208_372_02 ↗
30. Kanca · 2017
31. Tribological evaluation of biomedical polycarbonate urethanes against articular cartilage10.1016/j.jmbbm.2018.04.001 ↗
32. Kurtz · 2015
33. Future young patient demand for primary and revision joint replacement: National projections from 2010 to 203010.1007/s11999-009-0834-6 ↗
34. The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements10.1016/S0142-9612(98)00112-4 ↗
35. Transient viscoelastic lubrication analyses of UHMWPE hip replacements10.1016/j.triboint.2018.07.037 ↗
36. Material properties of ultra-high molecular weight polyethylene: Comparison of tension, compression, nanomechanics and microstructure across clinical formulations10.1016/j.jmbbm.2018.03.029 ↗
37. Lubrication and wear modeling of artificial hip joints: A review10.1016/j.triboint.2010.06.010 ↗
38. Cushion bearings versus large diameter head metal-on-metal bearings in total hip arthroplasty: a short-term metal ion study10.1007/s00402-011-1364-8 ↗
39. Soft matter lubrication: does solid viscoelasticity matter?10.1021/acsami.7b09381 ↗
40. Compliant layer acetabular cups: Friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint10.1243/09544119H06404 ↗
41. Polyurethane unicondylar knee prostheses: simulator wear tests and lubrication studies10.1088/0031-9155/52/1/013 ↗
42. Retrieval analysis of a polycarbonate-urethane acetabular cup: a case report10.1615/JLongTermEffMedImplants.v18.i1.570 ↗
43. In vitro macrophage response to polyethylene and polycarbonate-urethane particles10.1002/jbm.a.32529 ↗
44. What’s next? Alternative materials for articulation in total joint replacement10.1016/j.actbio.2012.03.029 ↗
45. Evaluation of the wear performance of a polycarbonate-urethane acetabular component in a hip joint simulator and comparison with UHMWPE and cross-linked UHMWPE10.1177/0885328210394471 ↗
46. Wang · 2005 · 729
47. Wang, F., Jin, Z., 2006. Lubrication modeling of artificial hip joints. In: IUTAM Symposium on Elastohydrodynamics and Microelastohydrodynamics, pp. 385–396.10.1007/1-4020-4533-6_28 ↗
48. A general elastohydrodynamic lubrication analysis of and artificial hip joints employing a compliant layered and socket under steady state rotation10.1243/0954411041932836 ↗
49. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles10.1097/00003086-199009000-00013 ↗
50. Explantation and analysis of the first retrieved human acetabular cup made of polycarbonate urethane: a case report10.1615/JLongTermEffMedImplants.v18.i1.580 ↗