Innovative implant design for continuous implant stability: A mechanical and histological experimental study in the iliac crest of goats
Source abstract
Abstract
OBJECTIVES: this in vivo study reports on mechanical torque data as well as the biological evaluation up to 6 weeks after placement of implants with a unique wide knife thread design in a goat iliac crest model. We hypothesized that implants with this thread design would show substantial primary stability at a continuous level toward secondary stability. METHODS: 64 MegaGen Anyridge® implants were used with diameters 3.5 mm, 4.0 mm, 5.0 mm and 6.0 mm (n = 8). Implants were placed monocortically in the iliac crest of 16 healthy female Saanen goats, both on the right (for torque measurements) and left side (for histology/-morphometry). Torque-in at implant installation and torque-out at 2 and 6 weeks of implantation was measured, as well as bone-to-implant contact (BIC) and bone-area between the screw threads (BA). RESULTS: Histology showed intimate bone-to-implant contact with a maturating trabecular structure between 2 and 6 weeks. Torque values showed a dependency on implant diameter. For all implant diameters, torque-in values were similar to torque-out values at 2 weeks. At 6 weeks however, all torque-out values were significantly increased. BIC and BA percentages showed similar values for all diameters at both 2 and 6 weeks. CONCLUSIONS: These results prove the absence of a lag-phase in implant stability for MegaGen Anyridge® implants in the goat iliac crest model. The increased torque-out values at 6 weeks without increasing BIC and BA percentages correlate with the observed maturation of bone-to-implant contact quality over time. CLINICAL SIGNIFICANCE: It is a challenge to optimize implants with continuous primary stability and rapid transition into secondary stability to minimize the duration of the lag-phase. The results of this study prove the absence of a lag-phase in implant stability for MegaGen Anyridge® implants. Consequently, the data from this work are important for the treatment of individual patients 'translating' these findings into clinical implant procedures.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone health and osteoporosis research · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. The effect of thread pattern upon implant osseointegration10.1111/j.1600-0501.2009.01800.x ↗
2. Osseointegrated titanium implants - requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man10.3109/17453678108991776 ↗
3. Calcium-phosphate-coated oral implants promote osseointegration in osteoporosis10.1177/0022034513505769 ↗
4. Validity and clinical significance of biomechanical testing of implant/bone interface10.1111/j.1600-0501.2006.01365.x ↗
5. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone10.1111/j.1365-2842.2010.02117.x ↗
6. Mechanisms of endosseous integration
7. Does length, diameter, or bone quality affect primary and secondary stability in self-tapping dental implants?10.1016/j.joms.2016.03.011 ↗
8. Initial interfacial healing events around calcium phosphate (Ca-P) coated oral implants10.1034/j.1600-0501.1997.080506.x ↗
9. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years10.1111/j.1600-0501.2012.02547.x ↗
10. Significance of primary stability for osseointegration of dental implants10.1111/j.1600-0501.2005.01201.x ↗
11. A four-year survival rate multicenter prospective clinical study on 377 implants: correlations between implant insertion torque, diameter, and bone quality10.1563/AAID-JOI-D-13-00206 ↗
12. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study10.1111/clr.12945 ↗
13. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years10.1111/j.1600-0501.2012.02546.x ↗
14. Temporal sequence of hard and soft tissue healing around titanium dental implants10.1111/prd.12054 ↗
15. A novel implantation model for evaluation of bone healing response to dental implants: the goat iliac crest10.1111/j.1600-0501.2009.01872.x ↗
16. In vivo bone response and mechanical evaluation of electrosprayed CaP nanoparticle coatings using the iliac crest of goats as an implantation model10.1016/j.actbio.2009.11.030 ↗
17. Snedecor · 1989
18. Metabolic-rate and body-size - a New view on the surface law for basic metabolic-rate10.1007/BF00707392 ↗
19. Biological limits of the undersized surgical technique: a study in goats10.1111/j.1600-0501.2010.02016.x ↗
20. Evaluation of primary and secondary stability of titanium implants using different surgical techniques10.1111/clr.12180 ↗
21. Comparison of different surface modifications for titanium implants installed into the goat iliac crest10.1111/clr.12529 ↗
22. A histological evaluation of TiO2-gritblasted and C-P magnetron sputter coated implants placed into the trabecular bone of the goat; Part 210.1034/j.1600-0501.2000.011004314.x ↗