This study aims to evaluate the effects of implant macrogeometry on the early period of the osseointegration process, comparing four different implant models through biomechanical and histological analysis after implantation in rabbit tibiae. Twenty New Zealand rabbits were used, evaluated at two different times (21 and 28 days) after installation of the implant. Eighty implants with different macrogeometries were used, forming four groups (n = 20 per group): cylindrical implants Ø4.1 mm and 8 mm in length (STRc group); cylindrical-conical implants Ø4.1 mm and 8 mm in length (STRt group); tapered implants Ø4.3 mm and 8 mm in length (NOBt group); and tapered implants with healing chambers Ø4.0 mm and 8 mm in length (MAEt group). Ten samples from each group were analyzed at each proposed time. The initial implant stability quotient (ISQ) was measured by resonance frequency analysis, both at the time of installation and at the time of sacrifice. In the histological sections, the percentage of bone-implant contact (BIC%), newly formed bone, osteoid matrix, and medullary spaces were measured in the pre-determined cortical and medullary bone portion for each sample. The three tapered implant groups (STRt, NOBt, and MAEt) showed higher values for the analyzed parameters in the early osseointegration period, in comparison with the cylindrical implant group (STRc). In all parameters, the three tapered groups showed no difference (p > 0.05); however, all three tapered groups presented significant differences, when compared to the cylindrical group (p < 0.05). No correlation was detected between the parameters analyzed. Within the limitations of the present study, in all parameters analyzed, the tapered implants demonstrated greater results when compared to the cylindrical implants.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. The effect of implant placement torque on crestal bone remodeling after 1 year of loading10.2147/CCIDE.S174895 ↗
2. Effect of drilling dimension on implant placement torque and early osseointegration stages: an experimental study in dogs10.1016/j.joms.2011.08.006 ↗
3. Effect of implant macrogeometry on peri-implant healing outcomes: a randomized clinical trial10.1007/s00784-018-2463-5 ↗
4. Can implant surfaces affect implant stability during osseointegration? A randomized clinical trial10.1590/1807-3107bor-2018.vol32.0110 ↗
5. A comparison of tapered and nontapered implants in the minipig10.11607/jomi.4712 ↗
6. The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: an experimental study in dogs10.1016/j.jmbbm.2011.06.016 ↗
7. Medium- and long-term survival rates of implant-supported single and partial restorations at a maximum follow-up of 12 Years: a retrospective study10.11607/ijp.6883 ↗
8. In vitro assessment of the functional dynamics of titanium with surface coating of hydroxyapatite nanoparticles10.3390/ma12050840 ↗
9. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants10.1016/j.jmbbm.2012.10.010 ↗
10. Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants10.1016/j.dental.2014.10.002 ↗
11. Interventions for replacing missing teeth: different types of dental implants
12. Current trends in dental implants10.5125/jkaoms.2014.40.2.50 ↗
13. Can changes in implant macrogeometry accelerate the osseointegration process?: an in vivo experimental biomechanical and histological evaluations10.1371/journal.pone.0233304 ↗
14. New implant macrogeometry to improve and accelerate the osseointegration: an in vivo experimental study10.3390/app9153181 ↗
15. Peri-implant bone behavior after single drill versus multiple sequence for osteotomy drill10.1155/2018/9756043 ↗
16. Effects on the osseointegration of titanium implants incorporating calcium-magnesium: a resonance frequency and histomorphometric analysis in rabbit tibia10.1111/clr.12909 ↗
17. Effects of the technique and drill design used during the osteotomy on the thermal and histological stimulation10.1038/s41598-020-77762-z ↗
18. Thoughts on limitations of animal models10.1016/j.parkreldis.2008.04.003 ↗
19. Recent advances in dental implants10.1186/s40902-017-0132-2 ↗
20. Role of primary stability for successful osseointegration of dental implants: factors of influence and evaluation
21. The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental study10.1016/j.ijom.2014.03.017 ↗
22. Effect of implant macro-design on primary stability: a prospective clinical study10.4317/medoral.21024 ↗
23. Rabbit as an animal model for experimental research10.4103/1735-3327.92960 ↗
24. The effect of osteotomy dimension on implant insertion torque, healing mode, and osseointegration indicators: a study in dogs10.1097/ID.0000000000000476 ↗
25. Surface roughness of dental implant and osseointegration10.1007/s12663-020-01437-5 ↗
26. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic review10.1016/j.ijom.2014.10.023 ↗
27. Surface modifications to enhance osseointegration-Resulting material properties and biological responses10.1002/jbm.b.34835 ↗
28. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants10.1111/j.1600-0501.2004.01041.x ↗
29. Is there a need for standardization of tightening force used to connect the transducer for resonance frequency analysis in determining implant stability?10.11607/jomi.7361 ↗
30. Analysis of trauma intensity during surgical bone procedures using NF-κB expression levels as a stress sensor: an experimental study in a wistar rat model
31. Blood vessels are concentrated within the implant surface concavities: a histologic study in rabbit tibia10.1007/s10266-013-0116-3 ↗
32. Experimental evaluation in rabbits of the effects of thread concavities in bone formation with different titanium implant surfaces10.1111/cid.12033 ↗
33. Tapered versus cylindrical implant: which shape inflicts less pain after dental implant surgery? A clinical trial10.1016/j.joms.2019.02.027 ↗
34. Impact of dental implant surface modifications on osseointegration10.1155/2016/6285620 ↗
35. The rabbit as experimental model for research in implant dentistry and related tissue regeneration10.3109/08941939.2013.778922 ↗
36. Influence of an alternative implant design and surgical protocol on primary stability10.1590/0103-6440201902324 ↗
37. Dental implant macro-design features can impact the dynamics of osseointegration10.1111/cid.12178 ↗
38. Comparison between tapered and cylindrical implants in the posterior regions of the mandible: a prospective, randomized, split-mouth clinical trial focusing on implant stability changes during early healing10.1111/cid.12501 ↗
39. Modifications of dental implant surfaces at the micro- and nano-level for enhanced osseointegration10.3390/ma13010089 ↗