A finite element study on femoral locking compression plate design using genetic optimization method
Source abstract
Abstract
The locking compression plate (LCP) and screw sets are widely used as internal fixator assemblies to treat long bone fractures. However, the surgeon's critical challenge is choosing the implant set (plate and screws) for each patient. The present study introduces a parametrized simulation-based optimization algorithm for determining an LC system with the best bone-implant stability. For this purpose, a three-dimensional fractured bone supported by an LC system was generated, and the discrete genetic optimization approach was utilized to design the optimum implant. Initially, an algorithm was developed to optimize the optimum layouts for different numbers of screws. For the middle third transverse fracture, six screws were selected as the optimal number of the screws. In a second stage, the model was run to determine the best LC plate dimensions for desired fractured bones. Finally, optimal plates were identified for simple middle third transverse, 60° middle third oblique, and distal third transverse femoral fractures. The results of these simulations and those for other fracture types can be exploited to achieve improved surgical outcomes by selecting proper implants and screws configurations.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone fractures and treatments · Hip and Femur Fractures
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. Biomechanical testing of the locking compression plate : when does the distance between bone and implant significantly reduce construct stability10.1016/j.injury.2006.08.058 ↗
2. Topology Optimization to reduce the stress shielding effect for orthopedic applications
3. Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analyses10.1016/j.medengphy.2007.12.009 ↗
4. Hip forces and gait patterns from rountine activities10.1016/S0021-9290(01)00040-9 ↗
5. Bucholz · 2010
6. Locking compression plate fixation of Vancouver type-B1 periprosthetic femoral fractures10.2106/00004623-200709000-00011 ↗
7. Computational investigations of mechanical failures of internal plate fixation10.1243/09544119JEIM670 ↗
8. Parametric design of patient-specific fixation plates for distal femur fractures
9. A novel computer-aided approach for parametric investigation of custom design of fracture fixation plates
10. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing10.1016/S0021-9290(98)00153-5 ↗
11. Multiscale investigation of the functional properties of the human femur10.1098/rsta.2008.0077 ↗
12. DePuy
13. Femur shaft [WWW Document], n.d. URL https://surgeryreference.aofoundation.org/orthopedic-trauma/adult-trauma/femoral-shaft (accessed 7.15.21).
14. Assessment of function-graded materials as fracture fixation bone-plates under combined loading conditions using finite element modelling10.1016/j.medengphy.2010.11.013 ↗
15. Guidelines for the clinical application of the LCP10.1016/j.injury.2003.09.026 ↗
16. The influence of induced micromovement upon the healing of experimental tibial fractures10.1302/0301-620X.67B4.4030869 ↗
17. A discussion on plating factors that affect stress shielding using finite element analysis10.1299/jbse.5.129 ↗
18. Preoperative planning in orthopedic trauma: benefits and contemporary uses
19. Hall · 2007
20. A modified method for assigning material properties to FE models of bones10.1016/j.medengphy.2007.05.006 ↗
21. Applications of finite element methods and discrete particle swarm optimization algorithms in design of locked compression plates
22. Implicit modeling of screw threads for ef fi cient fi nite element analysis of complex bone-implant systems
23. Distal femoral fractures10.1016/S0030-5898(20)32286-0 ↗
24. Simulation-based particle swarm optimization and mechanical validation of screw position and number for the fixation stability of a femoral locking compression plate
25. The biomechanical effect of bone quality and fracture topography on locking plate fixation in periprosthetic femoral fractures10.1016/j.injury.2014.10.060 ↗
26. Three hundred and twenty-one periprosthetic femoral fractures10.2106/00004623-200606000-00007 ↗
27. Risk factors for failure after treatment of a periprosthetic fracture of the femur
28. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation10.1097/BOT.0b013e3181be6720 ↗
29. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing10.1016/j.clinbiomech.2007.08.004 ↗
30. High failure rates of locking compression plate osteosynthesis with transverse fracture around a well-fixed stem tip for periprosthetic femoral fracture10.3390/jcm9113758 ↗
31. Genetic algorithms: an overview10.1002/cplx.6130010108 ↗
32. Mixed Integer ga Optimization - MATLAB & Simulink - MathWorks Deutschland [WWW Document], n.d. URL https://de.mathworks.com/help/gads/mixed-integer-optimization.html (accessed 7.6.21).
33. The effects of bone screw configurations on the interfragmentary movement in a long bone fixed by a limited contact locking compression plate10.4236/jbise.2015.89055 ↗
34. Abaqus2Matlab : a suitable tool for finite element post-processing10.1016/j.advengsoft.2017.01.006 ↗
35. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology10.1302/0301-620X.84B8.0841093 ↗
36. Patient-specific finite element modeling of bones10.1177/0954411912467884 ↗
37. Finite element-and design of experiment-derived optimization of screw configurations and a locking plate for internal fixation system10.1155/2019/5636528 ↗
38. Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled10.1016/j.injury.2003.09.021 ↗
39. Screw layout optimization to solve fatigue fracture of femoral Ti alloy metal plate
40. Comparison of micro-level and continuum-level voxel models of the proximal femur10.1016/j.jbiomech.2005.10.027 ↗
41. Experimental investigation of bone remodelling using composite femurs10.1016/S0268-0033(03)00072-X ↗
42. Prediction of the time course of callus stiffness as a function of mechanical parameters in experimental rat fracture healing studies--a numerical study10.1371/journal.pone.0115695 ↗
43. Finite element analysis of osteosynthesis screw fixation in the bone stock : an appropriate method for automatic screw modelling10.1371/journal.pone.0033776 ↗
44. The effect of the configuration of the screw fixation on the interfragmentary strain boonthum wongchai department of mechanical engineering , faculty of engineering at Si racha10.3844/ajassp.2012.842.845 ↗
45. Stress prediction in the dynamic compression plate with changing the configuration of the screw fixation10.3844/jcssp.2011.466.470 ↗
46. Clinical effect of locking compression plate via posterolateral approach in the treatment of distal femoral fractures : a new approach
47. Iterative approach for 3D reconstruction of the femur from un-calibrated 2D radiographic images Kibeom