journal article·2023-02Open access

Comparison of linear and nonlinear stepwise μFE displacement predictions to digital volume correlation measurements of trabecular bone biopsies

Pia Stefanek, Alexander Synek, Enrico Dall’Ara, Dieter H. Pahr

Abstract

Digital volume correlation (DVC) enables to evaluate the ability of μFE models in predicting experimental results on the mesoscale. In this study predicted displacement fields of three different linear and materially nonlinear μFE simulation methods were compared to DVC measured displacement fields at specific load steps in the elastic regime (StepEl) and after yield (StepUlt). Five human trabecular bone biopsies from a previous study were compressed in several displacement steps until failure. At every compression step, μCT images (resolution: 36 μm) were recorded. A global DVC algorithm was applied to compute the displacement fields at all loading steps. The unloaded 3D images were then used to generate homogeneous, isotropic, linear and materially nonlinear μFE models. Three different μFE simulation methods were used: linear (L), nonlinear (NL), and nonlinear stepwise (NLS). Regarding L and NL, the boundary conditions were derived from the interpolated displacement fields at StepEl and StepUlt, while for the NLS method nonlinear changes of the boundary conditions of the experiments were captured using the DVC displacement field of every available load step until StepEl and StepUlt. The predicted displacement fields of all μFE simulation methods were in good agreement with the DVC measured displacement fields (individual specimens: R2>0.83 at StepEl and R2>0.59 at StepUlt; pooled data: R2>0.97 at StepEl and R2>0.92 at StepUlt). At StepEl, all three simulation methods showed similar intercepts, slopes, and coefficients of determination while the nonlinear μFE models improved the prediction of the displacement fields slightly in all Cartesian directions at StepUlt (individual specimens: L: R2>0.59 and NL, NLS: R2>0.68; pooled data: L: R2>0.92 and NL, NLS: R2>0.94). Damaged/overstrained elements in L, NL, and NLS occurred at similar locations but the number of overstrained elements was overestimated when using the L simulation method. Considering the increased solving time of the nonlinear μFE models as well as the acceptable performance in displacement prediction of the linear μFE models, one can conclude that for similar use cases linear μFE models represent the best compromise between computational effort and accuracy of the displacement field predictions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Elasticity and Material Modeling · Cellular Mechanics and Interactions · Bone health and osteoporosis research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone10.1016/j.bone.2010.02.025 ↗
2. Characterization of the effects of x-ray irradiation on the hierarchical structure and mechanical properties of human cortical bone10.1016/j.biomaterials.2011.08.013 ↗
3. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
4. Image-based finite element analysis
5. Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: a validation study10.1016/j.jmbbm.2016.09.014 ↗
6. Improved fracture risk assessment based on nonlinear micro-finite element simulations from HRpQCT images at the distal radius10.1002/jbmr.1996 ↗
7. Femoral strength is better predicted by finite element models than QCT and DXA10.1016/S0021-9290(99)00099-8 ↗
8. Micro finite element models of the vertebral body: validation of local displacement predictions10.1371/journal.pone.0180151 ↗
9. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study10.1016/j.jbiomech.2014.07.019 ↗
10. Precision of digital volume correlation approaches for strain analysis in bone imaged with micro-computed tomography at different dimensional levels
11. Research on damage in trabecular bone of the healthy human acetabulum at small strains using nonlinear micro-finite element analysis10.1007/s12204-008-0623-5 ↗
12. A highly scalable matrix-free multigrid solver for μFE analysis based on a pointer-less octree10.1007/978-3-642-29843-1_56 ↗
13. Effects of tissue heterogeneity on trabecular micromechanics examined by microCT-based finite element analysis and digital volume correlation
14. An over-nonlocal implicit gradient-enhanced damage-plastic model for trabecular bone under large compressive strains10.1002/cnm.2728 ↗
15. Accuracy of finite element analyses of CT scans in predictions of vertebral failure patterns under axial compression and anterior flexion10.1016/j.jbiomech.2015.12.004 ↗
16. Material mapping of QCT-derived scapular models: a comparison with micro-CT loaded specimens using digital volume correlation10.1007/s10439-019-02312-2 ↗
17. Performance of QCT-Derived scapula finite element models in predicting local displacements using digital volume correlation10.1016/j.jmbbm.2019.05.021 ↗
18. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
19. Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis10.1016/j.medengphy.2013.02.001 ↗
20. Damage tolerance and toughness of elderly human femora10.1016/j.actbio.2021.01.011 ↗
21. Hierarchical microimaging of bone structure and function10.1038/nrrheum.2009.107 ↗
22. High-resolution finite element models with tissue strength asymmetry accurately predict failure of trabecular bone10.1016/S0021-9290(00)00149-4 ↗
23. Validation of finite element models of the mouse tibia using digital volume correlation10.1016/j.jmbbm.2018.06.022 ↗
24. Prediction of insertion torque and stiffness of a dental implant in bovine trabecular bone using explicit micro-finite element analysis10.1016/j.jmbbm.2019.06.024 ↗
25. A review on recent advances in the constitutive modeling of bone tissue10.1007/s11914-020-00631-1 ↗
26. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms10.1016/j.jbiomech.2017.04.007 ↗
27. A novel approach to evaluate the effects of artificial bone focal lesion on the three-dimensional strain distributions within the vertebral body
28. MicroFE models of porcine vertebrae with induced bone focal lesions: validation of predicted displacements with digital volume correlation10.1016/j.jmbbm.2021.104872 ↗
29. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
30. Nonlinear micro finite element models based on digital volume correlation measurements predict early microdamage in newly formed bone10.1016/j.jmbbm.2022.105303 ↗
31. Mechanical properties and the hierarchical structure of bone10.1016/S1350-4533(98)00007-1 ↗
32. Finite element analysis in bone research: a computational method relating structure to mechanical function10.1016/B978-0-08-055294-1.00093-3 ↗
33. Heterogeneous strain distribution in the subchondral bone of human osteoarthritic femoral heads, measured with digital volume correlation10.3390/ma13204619 ↗
34. Nonlinear micro‐CT based FE modeling of trabecular bone—sensitivity of apparent response to tissue constitutive law and bone volume fraction10.1002/cnm.2941 ↗
35. Modelling of bone fracture and strength at different length scales: a review
36. Experimental validation of a nonlinear μFE model based on cohesive-frictional plasticity for trabecular bone10.1002/cnm.2739 ↗
37. Effect of high-energy X-ray doses on bone elastic properties and residual strains10.1016/j.jmbbm.2011.05.035 ↗
38. Stipsitz
39. Efficient materially nonlinear μFE solver for simulations of trabecular bone failure10.1007/s10237-019-01254-x ↗
40. Prediction of the inelastic behaviour of radius segments: damage-based nonlinear micro finite element simulation vs pistoia criterion10.1016/j.jbiomech.2020.110205 ↗
41. Taylor · 2014
42. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement-bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
43. Elastic full-field strain analysis and microdamage progression in the vertebral body from digital volume correlation10.1111/str.12202 ↗
44. A survey of micro-finite element analysis for clinical assessment of bone strength: the first decade10.1016/j.jbiomech.2014.12.024 ↗
45. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models10.1016/0021-9290(95)80008-5 ↗
46. Micro-finite element simulation of trabecular-bone post-yield behaviour - effects of material model, element size and type10.1080/10255840701848756 ↗
47. SciPy 1.0: fundamental algorithms for scientific computing in Python10.1038/s41592-019-0686-2 ↗
48. Valid μ finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions10.1016/j.jbiomech.2010.02.026 ↗
49. A method for fracture toughness measurement in trabecular bone using computed tomography, image correlation and finite element methods10.1016/j.jmbbm.2020.103838 ↗
50. Relative roles of microdamage and microfracture in the mechanical behavior of trabecular bone10.1016/S0736-0266(01)00053-5 ↗
51. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements10.1115/1.2146001 ↗