Stability of ceramic coatings on retrieved knee prostheses
Source abstract
Abstract
Background In total knee arthroplasty, femoral components with coated or oxidized surfaces are commonly used as alternative to CoCrMo in metal sensitive patients. Data on the in vivo behaviour of different coating types is, however, rare. Aim of the study was the investigation of coating stability with respect to implant and patient specific parameters. Methods Coating thickness and coating thickness reduction, respectively, was measured at 37 retrieved femoral components with TiNbN, TiN, ZrN or oxidized zirconium (OxZr) surface by the crater grinding method. The results were correlated to surface type, manufacturer, time in vivo of the implant, patient body weight and patient activity. Results Mean coating thickness reduction in the overall retrieval collection was 0.6 μm ± 0.8 μm. There was no correlation between coating thickness reduction and coating type, time in vivo, patient body weight, and patient activity. If grouped according to manufacturers, implants of one manufacturer showed an increased coating thickness reduction. 10 of 37 retrievals exhibited coating abrasion with exposure of the underlying alloy. TiNbN coatings showed the highest incidence (9/17) of coating abrasion. No coating breakthrough was observed in the ZrN or OxZr surfaces. Conclusion Our results indicate that TiNbN coatings should be optimized to improve their wear resistance in the long-term.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Metal hypersensitivity in total hip and knee arthroplasty: current concepts
2. Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium10.1016/j.knee.2013.01.004 ↗
3. Evaluation of 1031 primary titanium nitride coated mobile bearing total knee arthroplasties in an orthopedic clinic10.5312/wjo.v8.i12.922 ↗
4. Posterior condyle surface damage on retrieved femoral knee components10.1016/j.arth.2011.03.011 ↗
5. Three-dimensional polyethylene wear of a press-fit titanium prosthesis: factors influencing generation of polyethylene debris10.1016/S0883-5403(97)90021-8 ↗
6. Metal hypersensitivity in total joint arthroplasty10.2106/JBJS.RVW.17.00169 ↗
7. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator10.1097/01.blo.0000148576.70780.13 ↗
8. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis10.1007/s00167-017-4578-7 ↗
9. Retrieval study of commercially available knee implant coatings TiN, TiNbN and ZrN on TiAl6V4 and CoCr28Mo610.1016/j.jmbbm.2020.104034 ↗
10. Matched-pair total knee arthroplasty retrieval analysis: oxidized zirconium vs. CoCrMo10.1016/j.knee.2010.08.011 ↗
11. A comparative surface topographical analysis of explanted total knee replacement prostheses: oxidised zirconium vs cobalt chromium femoral components10.1016/j.medengphy.2017.10.003 ↗
12. Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements10.1007/s00264-016-3314-0 ↗
13. Wear in total knee arthroplasty—just a question of polyethylene?10.1007/s00264-013-2162-4 ↗
14. Tribologie in der Hüftendoprothetik10.1007/s00132-021-04077-w ↗
15. Retrieval analysis of TiN (titanium nitride) coated knee replacements: coating wear and degradation in vivo10.1002/jbm.b.34473 ↗
16. Response by Dr. Lapaj to comment on Lapaj et al.: retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene10.1016/j.jmbbm.2016.04.026 ↗
17. No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial10.1007/s00167-020-05997-4 ↗
18. Metal allergy in primary and revision total knee arthroplasty: a scoping review and evidence-based practical approach10.1302/2633-1462.210.BJO-2021-0098.R1 ↗
19. Allergy in total knee arthroplasty: a review of the facts10.1302/0301-620X.98B4.36767 ↗
20. 2016 · 1
21. 2017 · 1
22. 2022 · 1
23. 2022 · 1
24. 2016
25. Damage from unintentional metal–metal articulation of CoCrMo, TiAlV, and oxidized zirconium knee replacements following polyethylene insert failure10.1016/j.wear.2014.11.007 ↗
26. Metal ion release barrier function and biotribological evaluation of a zirconium nitride multilayer coated knee implant under highly demanding activities wear simulation10.1016/j.jbiomech.2018.07.043 ↗
27. Polyethylene wear and metal release of TiNbN-coated knee implants
28. Reactive sputtered TiXNbYNZ thin films. I. Basic processing relationships10.1016/j.matchemphys.2018.12.033 ↗
29. Reactive sputtered TixNbyN coatings. II. Effect of common deposition parameters10.1016/j.matchemphys.2018.12.046 ↗
30. Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants
31. Titanium-nitride coating of orthopaedic implants: a review of the literature10.1155/2015/485975 ↗
32. No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty10.1007/s00167-014-3359-9 ↗
33. Twelve-year outcomes of an oxinium total knee replacement compared with the same cobalt-chromium design: an analysis of 17,577 prostheses from the Australian orthopaedic association national joint replacement registry10.2106/JBJS.16.00092 ↗