journal article·2011-10

Failure analysis of the fractured wires in sternal perichronal loops

Jesús Chao, Roberto Voces, Carmen Peña

Publisher page

Abstract

We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire fracture was un-branched and transgranular and proceeded by a high cycle fatigue process, apparently in the absence of corrosion. However, stress anlysis indicates that the effective stress produced during strong coughing is lower than the yield strength. Our findings suggest that in order to reduce the risk for sternal dehiscence, the diameter of the wire used should be increased.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Trauma Management and Diagnosis · Reconstructive Surgery and Microvascular Techniques · Shoulder and Clavicle Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. ASTM E112-96 · 2004
2. ASTM E45-97 · 2005
3. ASTM E352-93 · 2006
4. ASTM F1350-91 · 2008
5. The broken wire suture
6. Numerical simulation techniques to study the structural response of the human chest following median sternotomy10.1016/j.athoracsur.2005.03.043 ↗
7. A biomechanical study of median sternotomy closure techniques10.1016/S1010-7940(99)00014-7 ↗
8. Gere · 2002
9. Gere · 2002
10. The influence of a 3.5 NaCl solution on the fatigue damage evolution in a planar slip fcc stainless steel10.1016/0025-5416(85)90100-4 ↗
11. Mechanical analysis of midline sternotomy wound closure10.1016/S0022-5223(99)70251-5 ↗
12. NRIM Fatigue Data Sheet, 1979. Data Sheets on elevated—temperature high-cycle and low-cycle fatigue properties of SUS 316—HP (18Cr-12Ni-2Mo) hot rolled stainless steel plate. No. 15. National Research Institute for Metals, Tokyo, Japan.
13. Ratan · 1993
14. The mechanism of syncope after coughing10.1136/bmj.2.4841.860 ↗
15. Failure analysis of explanted sternal wires10.1016/j.biomaterials.2004.07.005 ↗
16. Corrosion of stainless steel wire alter long-term implantation10.1007/s10047-005-0321-0 ↗
17. Voces-Sánchez, R., 2009. Nueva Técnica de Cierre Posesternotomía. Estudio Clinico y Experimental. Ph.D. Thesis. Departamento de Cirugía de la Universidad de Medicina de Salamanca, Spain.