Topologically controlled tensile behaviour of braided prostheses for anterior cruciate ligaments
Source abstract
Abstract
Anterior cruciate ligament (ACL) is one of the most susceptible ligaments of the knee that can suffer injury. These ruptured ligaments can be treated through surgical intervention using a braided structure that either acts as a substitute graft in isolation or an augmentation device alongside the biological tissue. Therefore, the main objective of the research work is to present an analytical model for predicting the complete set of tensile properties of braided prosthesis consisting of multifilament strands based upon predefined braid geometry and constituent material properties. The model has also accounted for the kinematical changes under defined loading conditions. The research findings have been confirmed by making a comparison between the theoretical and experimental results. The tensile properties of braided prostheses predicted via analytical route matched reasonably well with the experimental results.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Adhesion, Friction, and Surface Interactions · Silk-based biomaterials and applications · Knee injuries and reconstruction techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Physical and chemical decay of prosthetic ACL in vivo implantation10.1016/0267-6605(94)90006-X ↗
2. Dacron augmentation in anterior cruciate ligament reconstruction in dogs10.1097/00003086-198403000-00043 ↗
3. Synthetic devices for reconstructive surgery of the cruciate ligaments: a systematic review10.1016/j.arthro.2014.11.032 ↗
4. Fiber based tissue engineering scaffold for ligament replacement: design considerations and in vitro evaluation10.1016/j.biomaterials.2004.05.014 ↗
5. A classification of prosthetic ligament failures
6. Analysis of retrieved polymer fiber based replacements for the ACL10.1016/S0142-9612(00)00114-9 ↗
7. Intraarticular replacement in the anterior cruciate ligament-deficient knee10.1177/036354658000800101 ↗
8. The ligament augmentation device: an historical perspective10.1016/S0749-8063(99)70061-7 ↗
9. Patients satisfaction needs as related to knee stability and objective findings after ACL reconstruction using the LARS artificial ligament10.1016/S0968-0160(00)00039-9 ↗
10. Mclntyre · 1995
11. Mechanical properties and modelling of a hydrophilic composite used as a biomaterial10.1016/j.compscitech.2005.05.022 ↗
12. Early failure in an artificial anterior cruciate ligament scaffold10.1016/S0968-0160(96)00225-6 ↗
13. A new generation of artificial ligaments in reconstruction of the anterior cruciate ligament. Two-year follow-up of randomised trial10.1302/0301-620X.84B3.0840356 ↗
14. The strength of the anterior cruciate ligament in humans and rhesusmonkeys10.2106/00004623-197658080-00006 ↗
15. Mechanical response of a tubular braided cable with an elastic core10.1177/004051757804800204 ↗
16. Geometrical modelling and control of a triaxial braiding machine for producing 3D preforms10.1016/S1359-835X(03)00061-7 ↗
17. Clinical experience with the Leeds-Keio artificial ligament in anterior cruciate ligament reconstruction: a prospective two-year follow-up study10.1177/036354659502300311 ↗
18. Tensile mechanics of braided sutures10.1177/0040517512445340 ↗
19. Tensile response of tubular braids with an elastic core10.1016/j.compositesa.2012.12.006 ↗
20. Tensile behaviour of structurally gradient braided prostheses for anterior cruciate ligaments10.1016/j.jmbbm.2015.09.018 ↗
21. Polypropylene braid augmented and nonaugmented intraarticular anterior cruciate ligament reconstruction10.1177/036354658501300507 ↗
22. Saraswat · 2015
23. Biocompatibility of polyethylene terephtalate (Trevira-hochfest) augmentation device in repair of the anterior cruciate ligament10.1016/S0142-9612(97)00201-9 ↗
24. Effect of braid angle on fatigue performance of biaxial braided composites10.1016/j.ijfatigue.2006.02.009 ↗
25. Clinical and functional outcome after anterior cruciate ligament reconstruction using the LARS™ system at a minimum follow-up of 10 years10.1016/j.knee.2015.06.003 ↗
26. Host response to implanted dacron grafts. A comparison between mesh and velour10.1001/archsurg.1975.01360180039008 ↗
27. Wet-spun silk fibroin scaffold with hierarchical structure for ligament tissue engineering10.1016/j.matlet.2014.07.115 ↗