Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall
Source abstract
Abstract
The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hernia repair and management · Surgical Sutures and Adhesives · Pelvic and Acetabular Injuries
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. Tuning adhesion failure strength for tissue-specific applications10.1016/j.actbio.2010.07.008 ↗
2. Behavior of a new long-chain cyanoacrylate tissue adhesive used for mesh fixation in hernia repair10.1016/j.jss.2016.09.021 ↗
3. Trasnporous hernia mesh fixation with fibrin sealant in a in vivo model of spray application10.1016/j.jss.2013.03.002 ↗
4. Objective hypoesthesia and pain after transabdominal preperitoneal hernioplasty: a prospective, randomized study comparing tissue adhesive versus spiral tacks10.1007/s00464-011-2003-8 ↗
5. Randomized, controlled, blinded trial of tissucol/tisseel for mesh fixation in patients undergoing lichtenstein technique for primary inguinal hernia repair: rationale and study design of the timeli trial10.1007/s10029-007-0315-3 ↗
6. Laparoscopic spray application of fibrin sealant effects on hemodynamics and spray efficiency at various application pressures and distances10.1007/s00464-007-9235-7 ↗
7. Fernández-Gutiérrez, M., Rodriguez-Mancheño, M., Pérez-Köhler, B., Pascual, G., Bellón, J.M., JS, J.S.R., 2016. Structural analysis and application of n-alkyl cyanoacrylate surgical adhesives to the fixation of meshes for hernia repair. Macromol Biosci 16, 1803–1814.10.1002/mabi.201600246 ↗
8. Assessment of pain and quality of life in lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin-sealant mesh fixation10.3389/fsurg.2014.00045 ↗
9. Meta-analysis of glue versus sutured mesh fixation for lichtenstein inguinal hernia repair10.1002/bjs.9072 ↗
10. Long-term anisotropic mechanical response of surgical meshes used to repair abdominal wall defects10.1016/j.jmbbm.2011.09.005 ↗
11. Hernández-Gascón, B., Peña, E., Melero, H., Pascual, G., Doblaré, M., M. P. Ginebra, M. P., Bellón, J., Calvo, B., 2011. Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall. Acta Biomater 7, 3905–3913.10.1016/j.actbio.2011.06.033 ↗
12. Junqueira · 2007
13. Efficiency and safety of mesh fixation in laparoscopic inguinal hernia repair using n-butyl cyanoacrylate: long-term biocompatibility in over 1,300 mesh fixations10.1007/s10029-011-0887-9 ↗
14. Glubran2 surgical glue: In vitro evaluation of adhesive and mechanical properties10.1016/j.jss.2009.01.034 ↗
15. Cyanoacrylate glue for intra-abdominal mesh fixation of polypropylene-polyvinylidene fluoride meshes in a rabbit model10.1016/j.jss.2009.11.710 ↗
16. Is it possible to eliminate suturesin open (lichtenstein techniques) and laparoscopic (totally extraperitoneal endoscopic) inguinal hernia repair? A randomized controlled trial with tissue adhesive (n-hexil cyanoacrylate)10.1177/1553350613517944 ↗
17. Chronic pain after mesh repair of inguinal hernia: a systematic review10.1016/j.amjsurg.2007.02.012 ↗
18. Randomized clinical trial of tissue glue versus absorbable sutures for mesh fixation in local anaesthetic lichtenstein hernia repair10.1002/bjs.7598 ↗
19. Cytotoxicity of cyanoacrylate-based tissue adhesives and short-term preclinical in vivo biocompatibility in abdominal hernia repair10.1371/journal.pone.0157920 ↗
20. Host tissue response by the expression of collagen to cyanoacrylate adhesives used in implant fixation for abdominal hernia repair10.1007/s10856-017-5869-8 ↗
21. Quinn, J., 2005. Tissue Adhesives in Clinical Medicine. No. v. 1 in Pmph USA Ltd Series. BC Decker, Incorporated.
22. Incisional abdominal hernia: the open mesh repair10.1007/s00423-003-0352-z ↗
23. Nbca medical adhesive (n-butyl-2-cyanoacrylate) versus suture for patch fixation in lichtenstein inguinal herniorrhaphy: a randomized controlled trial10.1016/j.surg.2011.09.031 ↗
24. Short- and long-term biomechanical and morphological study of new suture types in abdominal wall closure10.1016/j.jmbbm.2014.04.014 ↗
25. Biomechanical evaluation of fixation properties of fibrin glue for ventral incisional hernia repair10.1007/s10029-013-1163-y ↗