Mesh manipulation for local structural property tailoring of medical warp-knitted textiles
Source abstract
Abstract
Medical meshes are used as structural reinforcement both in clinical surgery and tissue engineering. However, complex loading conditions often found in such applications result in a non-homogenous stress distribution, for which the uniform reinforcement provided by the meshes is not optimal. This study aims to design a textile reinforcement with a spatially heterogeneous, load-tailored fiber architecture. To this end, we developed a simple method of manipulating a standard uniform mesh by stretching in warp and weft directions to various extents in order to control fiber orientation and fiber volume fraction. Subsequent thermal treatment locked the manipulated configurations allowing further use of the meshes. Firstly, samples in five uniform configurations (two manipulated longitudinally (warp direction), two manipulated transversely (weft direction), one non-manipulated) were obtained and analyzed regarding their morphology as well as their mechanical properties under cyclic uniaxial loading. Significant effects of the manipulation on key characteristics of the pores such as angles, side lengths, aspect ratios, and fiber volume fraction were shown. Tensile testing demonstrated the range of tensile properties achievable with the simple manipulation of the mesh, not only in magnitude but also in the shape of the stress-strain response curve. Finally, local manipulation combining different mesh configurations was exemplarily applied to create a spatially heterogeneous load-tailored reinforcement to match local strain directions in tissue-engineered tubular heart valves. The proposed method enables the use of well-established uniform medical meshes to produce load-tailored non-uniform mesh reinforcement for many applications in an easy-to-implement manner.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electrospun Nanofibers in Biomedical Applications · Textile materials and evaluations · Tissue Engineering and Regenerative Medicine
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Textile properties of synthetic prolapse mesh in response to uniaxial loading10.1016/j.ajog.2016.03.023 ↗
2. Ncorr: open-source 2D digital image correlation matlab software10.1007/s11340-015-0009-1 ↗
3. Evaluation of optical data gained by ARAMIS-measurement of abdominal wall movements for an anisotropic pattern design of stress-adapted hernia meshes produced by embroidery technology
4. An in vivo study of the dimensional changes of the aortic valve leaflets during the cardiac cycle10.1016/S0022-5223(19)40896-9 ↗
5. Biaxial analysis of synthetic scaffolds for hernia repair demonstrates variability in mechanical anisotropy, non-linearity and hysteresis10.1016/j.jmbbm.2014.06.001 ↗
6. A review on the Mullins effect10.1016/j.eurpolymj.2008.11.017 ↗
7. Mechanotransduction and fibrosis10.1016/j.jbiomech.2014.03.031 ↗
8. Small caliber compliant vascular grafts based on elastin-like recombinamers for in situ tissue engineering10.3389/fbioe.2019.00340 ↗
9. A new geometric model of laid-in weft-knitted fabrics10.1177/0040517521992765 ↗
10. Stress adapted embroidered meshes with a graded pattern design for abdominal wall hernia repair
11. Biomechanical properties of native and tissue engineered heart valve constructs10.1016/j.jbiomech.2013.09.023 ↗
12. Textile-based compression therapy in managing chronic oedema: complex interactions10.1177/0268355520947291 ↗
13. Regional stiffening of the mitral valve anterior leaflet in the beating ovine heart10.1016/j.jbiomech.2009.08.028 ↗
14. Can heterogeneous compression textile design reshape skin pressures? A fundamental study10.1177/0040517518779254 ↗
15. An approach to the optimization of preparation of bioprosthetic heart valves10.1016/0021-9290(91)90351-M ↗
16. Mechanical biocompatibility of highly deformable biomedical materials10.1016/j.jmbbm.2015.03.023 ↗
17. Stress analysis of the aortic valve during diastole: important parameters10.1016/0021-9290(76)90091-9 ↗
18. TexMi: development of tissue-engineered textile-reinforced mitral valve prosthesis10.1089/ten.tec.2013.0426 ↗
19. Tissue-engineered heart valve with a tubular leaflet design for minimally invasive transcatheter implantation10.1089/ten.tec.2014.0214 ↗
20. Mechanical characterization of the softening behavior of human vaginal tissue10.1016/j.jmbbm.2010.10.006 ↗
21. Mechanical equilibrium determines the fractal fiber architecture of aortic heart valve leaflets10.1152/ajpheart.1994.266.1.H319 ↗
22. Uniaxial and biaxial mechanical characterization of a prosthetic mesh at different length scales10.1016/j.jmbbm.2013.07.021 ↗
23. A non-biological model system to simulate the in vivo mechanical behavior of prosthetic meshes10.1016/j.jmbbm.2013.01.029 ↗
24. Sauren · 1981
25. Fluid-structure interaction simulation of artificial textile reinforced aortic heart valve: Validation with an in-vitro test10.1016/j.jbiomech.2018.07.018 ↗
26. Multi-scale modelling and simulation of a highly deformable embedded biomedical textile mesh composite10.1016/j.compositesb.2018.01.010 ↗
27. Multi-scale modelling of textile reinforced artificial tubular aortic heart valves10.1007/s11012-016-0479-y ↗
28. Effect of reinforcement volume fraction and orientation on a hybrid tissue engineered aortic heart valve with a tubular leaflet design10.1186/s40323-015-0039-3 ↗
29. Stresses of natural versus prosthetic aortic valve leaflets in vivo10.1016/S0003-4975(10)61250-7 ↗
30. Fiber heart valve prosthesis: influence of the fabric construction parameters on the valve fatigue performances10.1016/j.jmbbm.2014.08.015 ↗
31. Tissue-engineered fibrin-based heart valve with a tubular leaflet design10.1089/ten.tec.2013.0258 ↗
32. MR and PET-CT monitoring of tissue-engineered vascular grafts in the ovine carotid artery10.1016/j.biomaterials.2019.119228 ↗