journal article·2022-11Open access

Application of phase-field fracture theories and digital volume correlation to synchrotron X-ray monitored fractures in human trabecular bone: A case study

Anna Braesch-Andersen, Dan Wu, Stephen J. Ferguson, Cecilia Persson, Per Isaksson

Abstract

Fracture processes of trabecular bone have been studied using various approaches over the years. However, reliable methods to analyse fracture at the single trabecula level are limited. In this study, a digital volume correlation (DVC) and a phase-field fracture model are applied and contrasted for human trabecular bone to analyse its failure under global compression at high resolution. A human trabecular bone sample was fractured in situ under synchrotron-based X-ray micro computed tomography (CT). Reconstructed CT data was then used in DVC algorithms to obtain high-resolution displacement fields in the bone at different load steps. A high-resolution specimen-specific structural mesh was discretized from the CT data and used for the phase-field simulation of the fracturing bone. The DVC analysis showed opening mode cracks as well as shear mode cracks. Strains in cracked regions were analysed. The load distribution in the trabecular structure resulted in two completely separated fracture regions in the sample body. A phenomenon that was also captured in the phase-field model. The results encourage us to believe improvements in boundary conditions and material models are worthwhile pursuing. Findings in this study support further development of a phase-field method to analyse fracture in samples with complex morphology, such as trabecular bone, and the capacity of DVC to quantify strains and slowly growing stable fractures during step-wise loading of trabecular bone.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Numerical methods in engineering · Composite Material Mechanics · Rock Mechanics and Modeling

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. A review on phase-field models of brittle fracture and a new fast hybrid formulation10.1007/s00466-014-1109-y ↗
2. Regularized formulation of the variational brittle fracture with unilateral contact: numerical experiments10.1016/j.jmps.2009.04.011 ↗
3. On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone10.1016/j.bone.2010.02.025 ↗
4. Prediction of bone strength by ΜcT and MDCT-based finite-element-models: how much spatial resolution is needed?10.1016/j.ejrad.2013.10.024 ↗
5. Digital volume correlation: three-dimensional strain mapping using x-ray tomography10.1007/BF02323555 ↗
6. Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue10.1016/S0021-9290(03)00257-4 ↗
7. Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution10.1016/j.bone.2008.11.020 ↗
8. Influence of bone volume fraction and architecture on computed large-deformation failure mechanisms in human trabecular bone10.1016/j.bone.2006.06.016 ↗
9. Numerical experiments in revisited brittle fracture10.1016/S0022-5096(99)00028-9 ↗
10. Characterization of the bone-metal implant interface by digital volume correlation of in-situ loading using neutron tomography10.1016/j.jmbbm.2017.07.001 ↗
11. Crack dynamics and crack tip shielding in a material containing pores analysed by a phase field method10.1016/j.engfracmech.2018.11.013 ↗
12. DVC-based image subtraction to detect microcracking in lightweight concrete10.1111/str.12276 ↗
13. Deformable image registration and 3D strain mapping for the quantitative assessment of cortical bone microdamage10.1016/j.jmbbm.2011.12.009 ↗
14. A global digital volume correlation algorithm based on higher-order finite elements: implementation and evaluation10.1016/j.ijsolstr.2019.03.024 ↗
15. Strain energy density decompositions in phase-field fracture theories for orthotropy and anisotropy10.1016/j.ijsolstr.2020.04.022 ↗
16. Characterising variability and regional correlations of microstructure and mechanical competence of human tibial trabecular bone: an in-vivo HR-PQCT study10.1016/j.bone.2019.01.013 ↗
17. A phase-field model for strength and fracture analyses of fiber-reinforced composites10.1016/j.compscitech.2018.10.031 ↗
18. Revisiting brittle fracture as an energy minimization problem10.1016/S0022-5096(98)00034-9 ↗
19. The application of digital volume correlation (DVC) to study the microstructural behaviour of trabecular bone during compression10.1016/j.jmbbm.2013.09.014 ↗
20. Local strain and damage mapping in single trabeculae during three-point bending tests10.1016/j.jmbbm.2010.12.009 ↗
21. Biomechanics of trabecular bone10.1146/annurev.bioeng.3.1.307 ↗
22. Modeling the onset and propagation of trabecular bone microdamage during low-cycle fatigue10.1016/j.jbiomech.2007.10.020 ↗
23. Influence of trabecular bone on peri-implant stress and strain based on micro-CT finite element modeling of beagle dog10.1155/2016/3926941 ↗
24. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone10.1016/j.jbiomech.2007.04.019 ↗
25. A multi-purpose imaging endstation for high-resolution micrometer-scaled sub-second tomography10.1016/j.ejmp.2016.08.012 ↗
26. Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis10.1016/j.medengphy.2013.02.001 ↗
27. Matlab · 2020
28. A phase field model for rate-independent crack propagation: robust algorithmic implementation based on operator splits10.1016/j.cma.2010.04.011 ↗
29. Thermodynamically consistent phase-fieldmodels of fracture: variational principles and multi-field FE implementations10.1002/nme.2861 ↗
30. Bone mechanical properties in healthy and diseased states10.1146/annurev-bioeng-062117-121139 ↗
31. Trabecular bone microdamage and microstructural stresses under uniaxial compression10.1016/j.jbiomech.2004.05.013 ↗
32. A phase field method to simulate crack nucleation and propagation in strongly heterogeneous materials from direct imaging of their microstructure10.1016/j.engfracmech.2015.03.045 ↗
33. Initiation and propagation of complex 3D networks of cracks in heterogeneous quasi-brittle materials: direct comparison between in situ testing-MicroCT experiments and phase field simulations10.1016/j.jmps.2016.06.004 ↗
34. Convergence behavior of high- resolution finite element models of trabecular bone10.1115/1.2800865 ↗
35. Three-dimensional local measurements of bone strain and displacement: comparison of three digital volume correlation approaches10.1115/1.4030174 ↗
36. Optimization of digital volume correlation computation in SR-MicroCT images of trabecular bone and bone-biomaterial systems10.1111/jmi.12745 ↗
37. Effect of SR-MicroCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation10.1016/j.jmbbm.2018.08.012 ↗
38. Gradient damage models and their use to approximate brittle fracture10.1177/1056789510386852 ↗
39. Detection of crack onset in double cleavage drilled specimens of plaster under compression by digital image correlation - theoretical predictions based on a coupled criterion10.1016/j.euromechsol.2014.12.002 ↗
40. Fiji: an open-source platform for biological-image analysis10.1038/nmeth.2019 ↗
41. Fracture of viscoelastic solids modeled with a modified phase field method10.1016/j.cma.2018.09.018 ↗
42. Effects of trabecular type and orientation on microdamage susceptibility in trabecular bone10.1016/j.bone.2010.02.005 ↗
43. Digital volume correlation including rotational degrees of freedom during minimization10.1007/BF02410982 ↗
44. Crack nucleation in variational phase-field models of brittle fracture10.1016/j.jmps.2017.09.006 ↗
45. Phase field modeling of fracture in anisotropic brittle solids10.1016/j.ijnonlinmec.2017.06.018 ↗
46. Material heterogeneity in cancellous bone promotes deformation recovery after mechanical failure
47. Strain uncertainties from two digital volume correlation approaches in prophylactically augmented vertebrae: local analysis on bone and cement-bone microstructures10.1016/j.jmbbm.2016.12.006 ↗
48. Sub-trabecular strain evolution in human trabecular bone10.1038/s41598-020-69850-x ↗
49. Micro-finite element simulation of trabecular-bone post-yield behaviour - effects of material model, element size and type10.1080/10255840701848756 ↗
50. Young's modulus of trabecular bone at the tissue level: a review10.1016/j.actbio.2018.08.001 ↗
51. A combined experimental and numerical method to estimate the elastic modulus of single trabeculae10.1016/j.jmbbm.2021.104879 ↗