The influence of blood composition and loading frequency on the behavior of embolus analogs
Source abstract
Abstract
In cases of acute ischemic stroke (AIS), mechanical thrombectomy (MT) can be used to directly remove lodged thromboemboli. Despite improvements in patient outcomes, one of the key factors affecting MT success is the mechanical properties of the occlusive thrombus. Therefore, the goal of this study was to investigate the viscoelastic properties of embolus analogs (EAs) and determine the influence of EA hematocrit and loading frequency. Bovine blood EAs were created over a range of physiological hematocrits (0-60%) and cyclic uniaxial compression testing was performed at three loading frequencies to mimic in vivo loading conditions, followed by stress-relaxation testing. It was found that EAs exhibited behaviors typical of hyper-viscoelastic materials and that EA hematocrit played a large role in both EA stiffness and relaxation, with both parameters decreasing as hematocrit increased from 0 to 60%. The viscoelastic behavior of the EAs was also affected by the frequency at which they were loaded, with significant increases in peak stresses between the 0.5 and 2 Hz loaded EAs. Lower hematocrit EAs had very dense fibrin networks while the higher hematocrit EAs consisted of closely packed RBCs with little fibrin present. These results suggest that fibrin contributes to EA stiffness and relaxation behaviors while RBCs play a role in decreasing the overall viscous response and strain-rate dependency. An Ogden hyperelastic model was found to best reproduce the EA loading data while a 3-term Prony series was fit to the stress relaxation data. A hyper-viscoelastic modeling framework was then implemented combining the loading and stress-relaxation fits and the results could match the full cyclic loading data for EAs of varying hematocrit and loading frequency. The results of the experimental mechanical characterization and hyper-viscoelastic curve fitting can be incorporated in future modeling efforts to optimize mechanical thrombectomy for AIS patients.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Acute Ischemic Stroke Management · Diabetic Foot Ulcer Assessment and Management · Venous Thromboembolism Diagnosis and Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Mechanical characterization of thrombi retrieved with endovascular thrombectomy in patients with acute ischemic stroke10.1161/STROKEAHA.120.033527 ↗
2. Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs10.3174/ajnr.A2485 ↗
3. Blood clot fracture properties are dependent on red blood cell and fibrin content10.1016/j.actbio.2021.03.052 ↗
4. A new compressible hyperelastic model for the multi-axial deformation of blood clot occlusions in vessels10.1007/s10237-021-01446-4 ↗
5. Stent retrievers in acute ischemic stroke: complications and failures during the perioperative period10.3174/ajnr.A3746 ↗
6. Determination of the constitutive constants of nonlinear viscoelastic materials10.1023/B:MTDM.0000046750.65395.fe ↗
7. Comparative safety and efficacy of modified TICI 2b and TICI 3 reperfusion in acute ischemic strokes treated with mechanical thrombectomy10.1093/neuros/nyy097 ↗
8. Mechanical behavior of in vitro blood clots and the implications for acute ischemic stroke treatment10.1136/neurintsurg-2019-015489 ↗
9. Investigating the mechanical behavior of clot analogues through experimental and computational analysis10.1007/s10439-020-02570-5 ↗
10. Analysis of human emboli and thrombectomy forces in large-vessel occlusion stroke10.3171/2019.12.JNS192187 ↗
11. The mechanical characterization of bovine embolus analogues under various loading conditions10.1007/s13239-018-0352-3 ↗
12. Analysis of thrombi retrieved from cerebral arteries of patients with acute ischemic stroke10.1161/01.STR.0000230307.03438.94 ↗
13. Thrombectomy 6 to 24 hours after stroke with a mismatch between deficit and infarct10.1056/NEJMoa1706442 ↗
14. Large deformation isotropic elasticity–on the correlation of theory and experiment for incompressible rubberlike solids10.1098/rspa.1972.0026 ↗
15. Non-linear approach in visco-hyperelastic constitutive modelling of polyurethane nanocomposite10.1007/s11043-013-9208-2 ↗
16. Hyper-viscoelastic damage modeling of whole blood clot under large deformation
17. Some applications of elasticity theory to rubber engineering
18. Structural analysis of ischemic stroke thrombi: histological indications for therapy resistance10.3324/haematol.2019.219881 ↗
19. Nonlinear, dissipative phenomena in whole blood clot mechanics10.1039/D0SM01317J ↗
20. A whole blood thrombus mimic: constitutive behavior under simple shear10.1016/j.jmbbm.2020.104216 ↗
21. Finite element analysis of blood clots based on the nonlinear visco-hyperelastic model10.1016/j.bpj.2021.08.034 ↗
22. Heart disease and stroke statistics—2020 update: a report from the American Heart Association10.1161/CIR.0000000000000757 ↗
23. Some forms of the strain energy function for rubber10.5254/1.3538343 ↗