Numerical analysis of the mechanical response of novel swelling bone implants in polyurethane foams
Source abstract
Abstract
In this study, a numerical framework was developed in order to analyze the swelling properties, mechanical response and fixation strength of swelling bone anchors. Using this framework, fully porous and solid implants, along with a novel hybrid design (consisting of a solid core and a porous sleeve), were modeled and studied. Free swelling experiments were conducted to investigate their swelling characteristics. The finite element model of swelling was validated using the conducted free swelling. Compared with the experimental data, results obtained from the finite element analysis proved the reliability of this frame-work. Afterwards, the swelling bone anchors were studied embedded in artificial bones with different densities with two different interface properties: considering frictional interface between the bone anchors and artificial bones (simulating the stages prior to osteointegration, when the bone and implant are not fully bonded and the surface of the implant can slide along the interface), and perfectly bonded (simulating the stages subsequent to osteointegration, when the bone and implant are fully bonded). It was observed that the swelling considerably decreases while the average radial stress on the lateral surface of the swelling bone anchor surges in the denser artificial bones. Ultimately, the pull-out experiments and simulations of the swelling bone anchors from the artificial bones were conducted to look into the fixation strength of the swelling bone anchors. It was found that the hybrid swelling bone anchor exhibits mechanical and swelling properties close to those of solid bone anchors, while also bone in-growth is expected to happen, which is an integral factor to these bone anchors.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Synthesis and characterization of a poly (methyl methacrylate-acrylic acid) copolymer for bioimplant applications10.1002/(SICI)1097-4628(19970103)63:1<75::AID-APP8>3.0.CO;2-P ↗
2. Development of self-anchoring bone implants. i. processing and material characterization10.1002/(SICI)1097-4636(199724)38:4<314::AID-JBM3>3.0.CO;2-R ↗
3. Me- chanical strength and biocompatibility properties of materials for bone in- ternal fixation: a brief overview
4. Tissue engineered human tracheas for in vivo implantation10.1016/j.biomaterials.2010.08.005 ↗
5. The ultimate strength of suture anchors10.1016/0749-8063(95)90084-5 ↗
6. Arthroscopic bankart reconstruction with a bioabsorbable anchor10.1016/S1058-2746(03)00175-7 ↗
7. Treatment of osteochondral lesions of the talus with autologous chondrocyte implantation10.1097/00132587-200403000-00009 ↗
8. Holding power of orthopedic screws in the large metacarpal and metatarsal bones of calves10.2460/ajvr.1994.55.03.415 ↗
9. Role of material surfaces in regulating bone and cartilage cell response10.1016/0142-9612(96)85758-9 ↗
10. Pull-out strength of five suture anchors10.1016/S0749-8063(05)80354-8 ↗
11. Compression and friction properties of rigid polyurethane foams10.1177/0021955X6700300406 ↗
12. A prospective outcome and cost-effectiveness comparison between two ligament reattachment techniques using suture anchors for chronic ankle instability10.1177/1071100714552079 ↗
13. Comsol
14. Friction coefficient and effective interference at the implant-bone interface10.1016/j.jbiomech.2015.07.012 ↗
15. Fundamentals of poroelasticity
16. Complications of bioabsorbable suture anchors in the shoulder10.1177/0363546511417573 ↗
17. Medial canthal ligament reattachment in skull base surgery and trauma10.1097/00005537-200104000-00031 ↗
18. R. Frank, A. Romeo, Arthroscopic soft tissue reconstruction in anterior shoulder instability, Der Orthopäde 47, 121–128.10.1007/s00132-018-3532-9 ↗
19. Cellular materials as porous scaffolds for tissue engineering10.1016/S0079-6425(00)00018-9 ↗
20. On the mechanical behaviour of peek and ha cranial implants under impact loading10.1016/j.jmbbm.2017.01.012 ↗
21. The development of suture anchors for use in soft tissue fixation to bone10.1177/036354659402200214 ↗
22. Stimulation of bone formation by a swelling endosseous implant10.1002/jbm.820120612 ↗
23. Biological and mechanical characteristics of the interface between a new swelling anchor and bone10.1002/jor.1100180324 ↗
24. Osteolysis of the greater trochanter: a result of bone anchors used for abductor reattachment at total hip arthroplasty10.1016/j.arth.2004.12.052 ↗
25. Augmentation of suture anchors with magnesium phosphate cement–simple technique with striking effect10.1016/j.jmbbm.2022.105096 ↗
26. Moisture absorption/desorption effects on flexural property of glass-fiber-reinforced polyester laminates: three-point bending test and coupled hygro- mechanical finite element analysis10.3390/polym8080290 ↗
27. Trabecular deformations during screw pull-out: a micro-CT study of lapine bone10.1007/s10237-017-0891-9 ↗
28. S. Kalidindi, P. Ahmad, A Numerical Investigation of the Mechanics of Swelling-type Intramedullary Hip Implants.
29. Fixation of calcaneal avulsion fractures using screws with and without suture anchors: a biomechanical investigation10.3113/FAI.2007.1183 ↗
30. Suture anchor fixation of comminuted inferior pole patella fracture-novel technique: suture bridge anchor fixation technique10.1007/s00402-020-03671-5 ↗
31. Peek biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
32. The influence of mechanical function on the develop- ment and remodeling of the tibia. an experimental study in sheep10.2106/00004623-197961020-00019 ↗
33. The holding strength of cannulated screws compared with solid core screws in cortical and cancellous bone10.1097/00005131-199310000-00008 ↗
34. Calcific insertional achilles tendinopathy: reattachment with bone anchors10.1177/0363546503258923 ↗
35. Investigation of the mechanical properties and failure modes of hybrid natural fiber composites for potential bone fracture fixation plates10.1016/j.jmbbm.2016.08.035 ↗
36. Mechanical biocompatibility of highly deformable biomedical materials10.1016/j.jmbbm.2015.03.023 ↗
37. McDonald · 2021
38. Interface shear strength and fracture behaviour of porous glass-fibre-reinforced composite implant and bone model material10.1016/j.jmbbm.2011.05.037 ↗
39. Studies of the mechanical and thermal properties of cross-linked poly (methylmethacrylate-acrylic acid-allylmethacrylate)- modified bone cement10.1002/app.23239 ↗
40. Fixation strength of swellable bone anchors in low-density polyurethane foam10.1002/1097-4636(2001)58:2<137::AID-JBM1000>3.0.CO;2-S ↗
41. Experimental study on the loosening of pedicle screws implanted to synthetic bone vertebra models and under non-pull-out mechanical loads10.1016/j.jmbbm.2019.06.013 ↗
42. Marginal bone resorption at dental implant–rtg analysis
43. Prediction of time- dependent swelling of flexible polymer substrates using hygro-mechanical finite element simulations10.1039/C5SM03109E ↗
44. Suture anchor fixation of olecranon fractures: a case series10.1111/sae.12001 ↗
45. A biomechanical evaluation of suture anchors in repair of the rotator cuff, the Journal of Bone and Joint Surgery
46. Sawbones USA
47. Soft tissue reconstruction in the shoulder: com- parison of suture anchors, absorbable staples, and absorbable tacks10.1177/036354659402200523 ↗
48. Fixation pull-out response measurement of bone screws and porous-surfaced posts10.1016/0021-9290(94)90278-X ↗
49. A porous swelling copolymeric material for improved implant fixation to bone10.1002/jbm.b.35238 ↗
50. Biomechanical characterization of porous polysulfone orthopedic implants
51. Fixation strength of swelling copolymeric anchors in artificial bone
52. Fracture fixation10.1148/rg.236035159 ↗
53. Direct bone anchorage of external hearing aids10.1016/0141-5425(83)90080-8 ↗
54. Pullout strength of triply periodic minimal surface-structured bone implants10.1016/j.ijmecsci.2022.107795 ↗
55. A narrative review of the histological and histomorphometrical evaluation of the peri- implant bone in loaded and unloaded dental implants. a 30-year experience (1988–2018)10.3390/ijerph17062088 ↗
56. Development of self- anchoring bone implants. ii. bone-implant interface characteristics in vitro10.1002/(SICI)1097-4636(199724)38:4<328::AID-JBM4>3.0.CO;2-Q ↗
57. An “in vitro” experimental model to predict the mechanical behavior of macroporous scaffolds implanted in articular cartilage10.1016/j.jmbbm.2013.12.024 ↗
58. The history of suture anchors in orthopaedic surgery10.1016/j.clinbiomech.2018.11.008 ↗
59. Use of ultra- sonically interdigitated anchors in haglund's deformity correction surgery10.1177/1938640020908455 ↗