journal article·2020-01

Fluid viscosity but not surface tension, determines the tamponade effect of intravitreal fluids in a novel in vitro eye model of retinal detachment

Asaf Friehmann, Uri Zaretsky Eng, Alexander Rubowitz

Publisher page

Abstract

Purpose To determine the effect of varying surface tension and viscosity of fluids used as tamponade in an in vitro eye model of retinal detachment. Methods We used an in vitro eye model simulating retinal detachment. Fluids with varying surface tension and identical viscosity, and fluids with varying viscosities and identical surface tension were used as tamponade agents to prevent retinal detachment in the model, to determine which of these properties affects each fluid's effectiveness as a retinal tamponade. Results The membrane (simulating retinal detachment) changes over time in a vitro eye model were not affected by varying surface tension given constant fluid viscosity. However, membrane changes were proportional to the viscosity of the fluid, given constant surface tension. Conclusions The tamponade effect of an intravitreal fluid against retinal detachment may not be related as previously assumed, solely to surface tension, but rather is proportionally related to its viscosity.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Retinal and Macular Surgery · Intraocular Surgery and Lenses · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. American Academy of O · 2010
2. Intraocular fluid dynamics and retinal shear stress after vitrectomy and gas tamponade10.1167/iovs.10-6872 ↗
3. Silicone oil: different physical proprieties and clinical applications10.1155/2014/502143 ↗
4. An experimental model of vitreous motion induced by eye rotations10.1186/s40662-015-0020-8 ↗
5. A model for the fluid motion of vitreous humour of the human eye during saccadic movement10.1088/0031-9155/43/6/001 ↗
6. Vitreous substitutes10.1586/17469899.3.2.211 ↗
7. Computer modelling of the surface tension of the gas-liquid and liquid-liquid interface10.1039/C5CS00736D ↗
8. The dynamic surface tension of water10.1021/acs.jpclett.7b00267 ↗
9. Experimental evaluation of in vitro stability of purified polydimethylsiloxanes (silicone oil) in viscosity ranges from 1000 to 5000 centistokes10.1097/00006982-199212031-00007 ↗
10. Heavy tamponade 1: a review of indications, use, and complications10.1038/eye.2008.61 ↗
11. Mechanical models of the dynamics of vitreous substitutes10.1155/2014/672926 ↗
12. The concept of heavy tamponades-chances and limitations10.1007/s00417-008-0861-0 ↗
13. Vitreous substitutes: a comprehensive review10.1016/j.survophthal.2010.09.001 ↗
14. Liang · 2017
15. Micro-surface and -interfacial tensions measured using the micropipette technique: applications in ultrasound-microbubbles, oil-recovery, lung-surfactants, nanoprecipitation, and microfluidics10.3390/mi10020105 ↗
16. The physical and surgical aspects of silicone oil in the vitreous cavity10.1007/BF02334175 ↗
17. Mathematical model of flow in the vitreous humor induced by saccadic eye rotations: effect of geometry10.1007/s10237-009-0159-0 ↗
18. Traction on the retina induced by saccadic eye movements in the presence of posterior vitreous detachment10.1007/s10237-010-0226-6 ↗
19. Mixture of ether and silicone oil for the treatment of inferior complicated retinal detachment10.5301/ejo.5000215 ↗
20. Santhanam · 2016
21. Outcomes of complex retinal detachment repair using 1000- vs 5000-centistoke silicone oil10.1001/archopht.123.4.473 ↗
22. Tamponade or filling effect: changes of forces in myopic eyes10.1155/2014/618382 ↗
23. Feasibility of using experimental high viscosity silicone oils: a pilot study10.1186/s40942-017-0105-8 ↗
24. Mixing processes in the vitreous chamber induced by eye rotations10.1088/0031-9155/55/2/008 ↗
25. Suri · 2006
26. Volume displacement of scleral buckles10.1001/archopht.1985.01050120056019 ↗
27. Hydrodynamic instabilities in miscible fluids10.1088/1361-648X/aa9eaa ↗
28. Tamponade efficiency of perfluorohexyloctane and silicone oil solutions in a model eye chamber10.1136/bjo.2003.024737 ↗
29. The influence of explants on the physical efficiency of tamponade agents10.1007/s004170050325 ↗