journal article·2020-09Open access

Development of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms

Robert J. Cooper, Aiqin Liu, Gavin A. Day, Vithanage N. Wijayathunga, Louise M. Jennings, Ruth K. Wilcox, Alison C. Jones

Abstract

The successful development of cartilage repair treatments for the knee requires understanding of the biomechanical environment within the joint. Computational finite element models play an important role in non-invasively understanding knee mechanics, but it is important to compare model findings to experimental data. The purpose of this study was to develop a methodology for generating subject-specific finite element models of porcine tibiofemoral joints that was robust and valid over multiple different constraint scenarios. Computational model predictions of two knees were compared to experimental studies on corresponding specimens loaded under several different constraint scenarios using a custom designed experimental rig, with variations made to the femoral flexion angle and level of tibial freedom. For both in vitro specimens, changing the femoral flexion angle had a marked effect on the contact distribution observed experimentally. With the tibia fixed, the majority of the contact region shifted to the medial plateau as flexion was increased. This did not occur when the tibia was free to displace and rotate in response to applied load. These trends in contact distribution across the medial and lateral plateaus were replicated in the computational models. In an additional model with the meniscus removed, contact pressures were elevated by a similar magnitude to the increase seen when the meniscus was removed experimentally. Overall, the models were able to capture specimen-specific trends in contact distribution under a variety of different loads, providing the potential to investigate subject-specific outcomes for knee interventions.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Knee injuries and reconstruction techniques · Total Knee Arthroplasty Outcomes · Lower Extremity Biomechanics and Pathologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Combined measurement and modeling of specimen-specific knee mechanics for healthy and ACL-deficient conditions10.1016/j.jbiomech.2017.04.008 ↗
2. A comparison between dynamic implicit and explicit finite element simulations of the native knee joint10.1016/j.medengphy.2016.06.001 ↗
3. The influence of ligament modelling strategies on the predictive capability of finite element models of the human knee joint10.1016/j.jbiomech.2017.08.030 ↗
4. Review of the biomechanics and biotribology of osteochondral grafts used for surgical interventions in the knee10.1177/0954411915615470 ↗
5. The impact of osteoarthritis: implications for research10.1097/01.blo.0000143938.30681.9d ↗
6. Finite element models of the tibiofemoral joint: a review of validation approaches and modelling challenges10.1016/j.medengphy.2019.08.002 ↗
7. Cooper
8. Accuracy of circular contact area measurements with thin-film pressure sensors10.1016/j.jbiomech.2006.12.002 ↗
9. Open knee: open source modeling and simulation in knee biomechanics
10. Deciphering the “art” in modeling and simulation of the knee joint10.1115/1.4043346 ↗
11. A hydrogel meniscal replacement: knee joint pressure and distribution in an ovine model compared to native tissue10.1007/s10439-018-2069-8 ↗
12. Medial meniscal displacement and strain in three dimensions under compressive loads: MR assessment10.1002/jmri.24461 ↗
13. Frictional properties of the meniscus improve after scaffold-augmented repair of partial meniscectomy: a pilot study10.1007/s11999-011-1854-6 ↗
14. Reducing uncertainty when using knee-specific finite element models by assessing the effect of input parameters10.1002/jor.23513 ↗
15. Deformation of articular cartilage during static loading of a knee joint--experimental and finite element analysis10.1016/j.jbiomech.2014.04.013 ↗
16. Nanoindentation of the insertional zones of human meniscal attachments into underlying bone10.1016/j.jmbbm.2008.10.005 ↗
17. Partial meniscectomy changes fluid pressurization in articular cartilage in human knees10.1115/1.4005764 ↗
18. Recent advances in computational mechanics of the human knee joint10.1155/2013/718423 ↗
19. Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator10.1016/j.jbiomech.2015.07.043 ↗
20. Development of a pre-clinical experimental simulation model of the natural porcine knee with appropriate ligamentous constraints
21. Finite element simulation of articular contact mechanics with quadratic tetrahedral elements10.1016/j.jbiomech.2016.01.024 ↗
22. Finite element simulations of a focal knee resurfacing implant applied to localized cartilage defects in a sheep model10.1016/j.jbiomech.2010.12.026 ↗
23. Tribological testing of articular cartilage of the medial compartment of the knee using a friction simulator10.1016/j.triboint.2008.03.012 ↗
24. Computational investigation of the time-dependent contact behaviour of the human tibiofemoral joint under body weight10.1177/0954411914559737 ↗
25. The effects of geometric uncertainties on computational modelling of knee biomechanics10.1098/rsos.170670 ↗
26. Patient-specific knee joint finite element model validation with high-accuracy kinematics from biplane dynamic Roentgen stereogrammetric analysis10.1016/j.jbiomech.2008.06.027 ↗
27. Applicability analysis of validation evidence for biomedical computational models10.1115/1.4037671 ↗
28. Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics10.1016/j.clinbiomech.2005.01.009 ↗
29. The risk of symptomatic knee osteoarthritis after arthroscopic meniscus repair vs partial meniscectomy vs the general population
30. Tissue material properties and computational modelling of the human tibiofemoral joint: a critical review10.7717/peerj.4298 ↗
31. A comparative anatomical study of the human knee and six animal species10.1016/j.knee.2011.07.005 ↗
32. Compression-rate-dependent nonlinear mechanics of normal and impaired porcine knee joints10.1186/s12891-017-1805-9 ↗
33. Computational biomechanics of articular cartilage of human knee joint: effect of osteochondral defects10.1016/j.jbiomech.2009.07.022 ↗
34. Comparison of hexahedral and tetrahedral elements in finite element analysis of the foot and footwear10.1016/j.jbiomech.2011.05.006 ↗
35. Anatomical study: comparing the human, sheep and pig knee meniscus10.1186/s40634-016-0071-3 ↗
36. Influence of meniscectomy and meniscus replacement on the stress distribution in human knee joint10.1007/s10439-008-9515-y ↗
37. Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading10.1016/j.jbiomech.2016.02.033 ↗
38. Collagen morphology in human meniscal attachments: a SEM study10.3109/03008200903349639 ↗
39. The combined effect of frontal plane tibiofemoral knee angle and meniscectomy on the cartilage contact stresses and strains10.1007/s10439-009-9781-3 ↗
40. Magnetic resonance image analysis of meniscal translation and tibio-menisco-femoral contact in deep knee flexion10.1002/jor.20553 ↗
41. Multiobjective optimization of cartilage stress for non-invasive, patient-specific recommendations of high tibial osteotomy correction angle--a novel method to investigate alignment correction10.1016/j.medengphy.2016.11.013 ↗
42. 3D finite element model of meniscectomy: changes in joint contact behavior10.1115/1.2132370 ↗
43. Influence of meniscus shape in the cross sectional plane on the knee contact mechanics10.1016/j.jbiomech.2015.03.002 ↗
44. The influence of articular cartilage thickness reduction on meniscus biomechanics10.1371/journal.pone.0167733 ↗