journal article·2021-12

Comparison of long-term kinematics and wear of total knee arthroplasty implant designs

Caleigh E. Bourdon, Jordan S. Broberg, Richard W. McCalden, Douglas D. Naudie, Steven J. MacDonald, Brent A. Lanting, Matthew G. Teeter

Publisher page

Abstract

We sought to evaluate wear and kinematics in well-established implants of posterior stabilized (PS) and cruciate retaining (CR) designs. Ninety-one knees implanted for at least five years were examined. The implants were Genesis II PS (Smith & Nephew, Memphis, TN), Sigma PS (DePuy Synthes, Warsaw, IN), or Sigma CR. Radiostereometric analysis (RSA) images were acquired at multiple flexion angles and the 3D positions of the implant components were determined using model-based RSA software. The location of the center of the contact area between the femoral and polyethylene components was used to obtain contact kinematics, and the magnitude of the virtual intersection between the components indicated linear wear. All three groups had paradoxical anterior motion on both condyles, experienced similar net external rotation, and exhibited instances of internal rotation during flexion. The maximum observed wear rate was significantly greater for the Sigma PS than the Genesis II PS on the medial condyle (mean difference = 0.032 mm/year, p = 0.044), but not the lateral condyle, while there was no difference between the Sigma PS and Sigma CR for either condyle. Knees with lateral condylar separation had greater maximum wear rates on the medial condyle (mean difference = 0.033 mm/year, p = 0.001), while those with medial condylar separation had greater maximum wear rates on the lateral condyle (mean difference = 0.044 mm/year, p = 0.014). At long term follow-up in patients with well-functioning implants, there were differences in kinematics and wear resistance between implants. These results suggest that implant design affects long-term kinematics and wear in well-functioning implants and that condylar separation should be avoided to minimize wear.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Total Knee Arthroplasty Outcomes · Orthopaedic implants and arthroplasty · Knee injuries and reconstruction techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Total knee arthroplasty kinematics10.1016/j.arth.2019.05.037 ↗
2. The Genesis II in primary total knee replacement: a systematic literature review of clinical outcomes10.1016/j.knee.2011.02.003 ↗
3. Comparison of contact kinematics in posterior-stabilized and cruciate-retaining total knee arthroplasty at long-term follow-up10.1016/j.arth.2019.07.046 ↗
4. Asymmetric polyethylene inserts promote favorable kinematics and better clinical outcome compared to symmetric inserts in a mobile bearing total knee arthroplasty10.1007/s00167-018-5207-9 ↗
5. In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty10.1016/j.arth.2007.09.019 ↗
6. Long-term results of posterior-cruciate-retaining Genesis I total knee arthroplasty10.1007/s00776-011-0152-1 ↗
7. The influence of total knee arthroplasty geometry on mid-flexion stability: an experimental and finite element study10.1016/j.jbiomech.2013.01.025 ↗
8. Five-year results of the Sigma total knee arthroplasty10.1016/j.knee.2006.06.003 ↗
9. Comparison of quasi-static and dynamic squats: a three-dimensional kinematic, kinetic and electromyographic study of the lower limbs10.1016/j.gaitpost.2014.02.016 ↗
10. Mobile-bearing total knee arthroplasty: design factors in minimizing wear
11. Femoral condylar lift-off in vivo in total knee arthroplasty
12. Conventry award paper: multicenter determination of in vivo kinematics after total knee arthroplasty10.1097/01.blo.0000092986.12414.b5 ↗
13. Polyethylene wear and variations in knee kinematics
14. In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis10.1302/0301-620X.101B11.BJJ-2018-1447.R2 ↗
15. The effect of total knee arthroplasty on knee joint kinematics and kinetics during gait10.1016/j.arth.2010.03.021 ↗
16. The influence of femoral condylar lift-off on the wear of artificial knee joints10.1243/09544119JEIM215 ↗
17. Comparison of patient-reported outcomes based on implant brand in total knee arthroplasty
18. In vivo measurement of total knee replacement wear10.1016/S0968-0160(03)00070-X ↗
19. Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses10.1007/s11999-009-1179-x ↗
20. Tibiofemoral conformity variation offers changed kinematics and wear performance of customized posterior-stabilized total knee arthroplasty10.1007/s00167-018-5045-9 ↗
21. The role of polyethylene design on postoperative TKA flexion: an analysis of 1534 cases10.1007/s11999-009-1127-9 ↗
22. Retrieval analysis of cruciate-retaining and posterior-stabilized total knee arthroplasty and correlations to laxity and wear10.1016/j.arth.2020.03.027 ↗
23. A novel method for in vivo knee prosthesis wear measurement10.1016/j.jbiomech.2004.02.023 ↗
24. Current total knee designs: does baseplate roughness or locking mechanism design affect polyethylene backside wear?
25. The kinematics and stability of single‐radius versus multi‐radius femoral components related to Mid‐range instability after TKA10.1002/jor.22170 ↗
26. In vitro quantification of wear in tibial inserts using microcomputed tomography10.1007/s11999-010-1490-6 ↗
27. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography
28. Radiostereometric analysis permits in vivo measurement of very small levels of wear in TKA10.1097/CORR.0000000000000399 ↗
29. Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty10.1007/s00167-017-4765-6 ↗
30. Knee joint kinematics, fixation and function related to joint area design in total knee arthroplasty10.1080/000164702760300299 ↗
31. Model-based Roentgen stereophotogrammetry of orthopaedic implants10.1016/S0021-9290(01)00028-8 ↗
32. The impact of coronal plane alignment on polyethylene wear and damage in total knee arthroplasty: a retrieval study10.1016/j.arth.2016.12.048 ↗
33. Comparison of stability and kinematics of the natural knee versus a PS TKA with a ‘third condyle’10.1007/s00167-014-3016-3 ↗
34. In vivo determination of cam-post engagement in fixed and mobile-bearing TKA10.1007/s11999-013-3257-3 ↗