Experimental validation of a micro-CT finite element model of a human cadaveric mandible rehabilitated with short-implant-supported partial dentures
Source abstract
Abstract
PURPOSE: This study aimed to address the predictive value of a micro-computed tomography (μCT)-based finite element (μFE) model of a human cadaveric edentulous posterior mandible, rehabilitated by short dental implants. Hereby, three different prosthetic/implant configurations of fixed partial dentures ("Sp"-3 splinted crowns on 3 implants, "Br" - Bridge: 3 splinted crowns on 2 implants, and "Si"- 3 single crowns) were analysed by comparing the computational predictions of the global stiffness with experimental data. METHODS: Experimental displacement of the bone/implant/prosthesis system was measured under axial and oblique loads of 100 N using an optical deformation system (GOM Aramis) and the overall movement of the testing machine (Zwick Z030). Together with the measured machine force, an "Aramis" (optical markers) and "Zwick" (test machine) stiffness were calculated. FE models were created based on μCT-scans of the cadaveric mandible sample (n = 1) before and after implantation and using stl-files of the crowns. The same load tests and boundary conditions were simulated on the models and the μFE-results were compared to experimental data using linear regression analysis. RESULTS: of 0.80, but the FEA-stiffness was 7.2 times higher. The factor was highly dependent on the test configuration. Sp-configuration showed the largest stiffness followed by Br-configuration (17% difference in experiment and 21% in FEA). CONCLUSIONS: The current study showed good qualitative agreement between the experimental and predicted global stiffness of different short implant configurations. It could be deduced that 1:1 splinting of the short implants by the crowns is most favorable for the stiffness of the implant/prosthesis system. However, in the clinical context, the absolute in silico readings must be interpreted cautiously, as the FEA showed a considerable overestimation of the values.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Facial Trauma and Fracture Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (55)
Show source-provided references
1. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification10.1002/jbm.a.30894 ↗
2. A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants10.1111/j.1708-8208.2007.00059.x ↗
3. Finite element modeling mesh quality, energy balance and validation methods: a review with recommendations associated with the modeling of bone tissue10.1016/j.jbiomech.2013.03.022 ↗
4. 'Finite element analysis of dental implants with validation: to what extent can we expect the model to predict biological phenomena? A literature review and proposal for classification of a validation process10.1186/s40729-018-0119-5 ↗
5. Cook · 2001
6. 'Effect of crown-to-implant ratio and crown height space on marginal bone stress: a finite element analysis10.1186/s40729-021-00368-1 ↗
7. 'Should the restoration of adjacent implants be splinted or nonsplinted? A systematic review and meta-analysis10.1016/j.prosdent.2018.03.004 ↗
8. 'Considerations for reporting finite element analysis studies in biomechanics10.1016/j.jbiomech.2011.11.038 ↗
9. 'Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up10.5051/jpis.2015.45.6.210 ↗
10. 'Bone's mechanostat: a 2003 update10.1002/ar.a.10119 ↗
11. 'A finite element analysis to compare stress distribution on extra-short implants with two different internal connections10.3390/jcm8081103 ↗
12. 'Comparison of finite element results with photoelastic stress analysis around dental implants with different threads10.17219/dmp/85077 ↗
13. 'Methods used for assessing stresses in buccomaxillary prostheses: photoelasticity, finite element technique, and extensometry10.1097/SCS.0b013e31819ba3a6 ↗
14. Occlusion in implant dentistry. A review of the literature of prosthetic determinants and current concepts
15. Splinting effect on posterior implants under various loading modes: a 3D finite element analysis
16. 'Biostatistics series module 6: correlation and linear regression10.4103/0019-5154.193662 ↗
17. 'Validation of computational models in biomechanics10.1243/09544119JEIM649 ↗
18. 'Zirconia: established facts and perspectives for a biomaterial in dental implantology10.1002/jbm.b.31147 ↗
19. 'Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading
20. Influence of forces on peri-implant bone10.1111/j.1600-0501.2006.01360.x ↗
21. Long-term retrospective study based on implant success rate in patients with risk factor: 15-year follow-up10.5005/jp-journals-10024-2217 ↗
22. 'Bite force and influential factors on bite force measurements: a literature review
23. Occlusion on oral implants: current clinical guidelines10.1111/joor.12239 ↗
24. 'Finite element analysis of bone-implant biomechanics: refinement through featuring various osseointegration conditions10.1016/j.ijom.2011.12.026 ↗
25. Patient selection and preparation
26. Splinted and nonsplinted crowns with different implant lengths in the posterior maxilla by three-dimensional finite element analysis
27. Guidelines for developing and reporting machine learning predictive models in biomedical research: a multidisciplinary view10.2196/jmir.5870 ↗
28. 'Success rate of short dental implants supporting single crowns and fixed bridges10.1111/clr.12693 ↗
29. 'The prosthetic influence and biomechanics on peri-implant strain: a systematic literature review of finite element studies10.5037/jomr.2016.7304 ↗
30. 'Comparison of stress and strain distribution around splinted and nonsplinted 6-mm short implants in posterior mandible: a finite element analysis study10.1097/ID.0000000000000709 ↗
31. Finite element contact analysis as a critical technique in dental biomechanics: a review10.1016/j.jpor.2014.03.001 ↗
32. 'Dental implants press fit phenomena: biomechanical analysis considering bone inelastic response10.1016/j.dental.2008.11.002 ↗
33. Active tactile sensibility of three-unit implant-supported FPDs versus natural dentition
34. Survival rates of short dental implants (</=6 mm) compared with implants longer than 6 mm in posterior jaw areas: a meta-analysis10.1111/clr.13289 ↗
35. '3D-FEA of osseointegration percentages and patterns on implant-bone interfacial stresses10.1016/S0300-5712(96)00061-9 ↗
36. Rehabilitation of the atrophic mandible with short implants in different positions: a finite elements study10.1016/j.msec.2017.03.310 ↗
37. Use of stress analysis methods to evaluate the biomechanics of oral rehabilitation with implants10.1563/AAID-JOI-D-11-00066 ↗
38. Clinical outcomes of partial and full-arch all-ceramic implant-supported fixed dental prostheses. A systematic review and meta-analysis10.1111/clr.13345 ↗
39. Long-term effectiveness of 6 mm micro-rough implants in various indications: a 4.6- to 18.2-year retrospective study10.1111/clr.13795 ↗
40. 'Key factors influencing short implant success10.1007/s10006-020-00841-y ↗
41. Short dental implants: a review of literature10.1615/JLongTermEffMedImplants.2020033390 ↗
42. Application of finite element model in implant dentistry: a systematic review10.4103/JPBS.JPBS_296_18 ↗
43. Roarche · 1998
44. Long-term follow-up of single crowns supported by short, moderately rough implants-A prospective 10-year cohort study10.1111/clr.13386 ↗
45. Assessment of maximum voluntary bite force in adults with normal occlusion and different types of malocclusions10.5005/jp-journals-10024-1181 ↗
46. 'Implants and the periodontium
47. Bone particles and the undersized surgical technique10.1177/0022034510363263 ↗
48. Immediate loading implants: review of the critical aspects10.11138/orl/2017.10.2.129 ↗
49. Finite element analysis of bone stress in the posterior mandible using regular and short implants, in the same context, with splinted and nonsplinted prostheses10.11607/jomi.5611 ↗
50. 'Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae10.1007/s10237-011-0347-6 ↗
51. 'Clinical behavior of short dental implants: systematic review and meta-analysis10.3390/jcm9103271 ↗
52. Extracting clinically relevant data from finite element simulations10.1016/j.clinbiomech.2005.01.010 ↗
53. Generation of microdamage around endosseous implants10.1111/j.1600-0501.2009.01808.x ↗
54. Effect of model parameters on finite element analysis of micromotions in implant dentistry10.1563/AAID-JOI-D-11-00221 ↗
55. Short versus standard implants for single-crown restorations in the posterior region: a systematic review and meta-analysis10.1016/j.prosdent.2019.09.030 ↗