Measuring intraocular pressure (IOP) is crucial and remains challenging in diagnosing glaucoma, as it is associated with cornea deformation during inflation. In this study, a three-dimensional analytical model based on hyperelastic constitutive relationship to predict correlation between cornea vertex displacement and the IOP is proposed. The analytical model is validated by rigorous experiments. Rabbit corneas were selected for this study and their mechanical properties were obtained using uniaxial tensile tests. To mimic the environment in which the cornea exists, an artificial anterior chamber equipped with water-injection pipelines was constructed to study the relationship between the corneal vertex displacement with IOP value in practical situation. The experimental results of rabbits corneas prove that the IOP can be deduced based on the measured corneal vertex displacement by the analytical model. Furthermore, subtle difference occurs when comparing the calculated human IOPs with those measured by medical equipment, demonstrating that the proposed method is suitable for monitoring the IOP of human. This novel IOP predicting method provides new inspiration for the design of eyepieces, as well as the preoperative preparation for laser surgery and evaluation of corneal damage.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Glaucoma and retinal disorders · Corneal surgery and disorders · Corneal Surgery and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (36)

Show source-provided references
1. Effect of the second invariant of the Cauchy–Green deformation tensor on the local dynamics of dielectric elastomers10.1016/j.ijnonlinmec.2021.103807 ↗
2. Application of structural analysis to the mechanical behaviour of the cornea10.1098/rsif.2004.0002 ↗
3. Characterization of non-linear mechanical behavior of the cornea10.1038/s41598-020-68391-7 ↗
4. Variations in eyeball diameters of the healthy adults10.1155/2014/503645 ↗
5. The architecture of the corneal stroma10.1136/bjo.85.4.379 ↗
6. Constitutive laws for biomechanical modeling of refractive surgery10.1115/1.2796033 ↗
7. IntraLase femtosecond laser vs mechanical microkeratomes in LASIK for myopia: a systematic review and meta-analysis10.3928/1081597X-20111228-02 ↗
8. Hyperelastic materials behavior modeling using consistent strain energy density functions10.1007/s00707-009-0239-3 ↗
9. Open-angle glaucoma
10. The mechanical properties of the rabbit and human cornea10.1016/0021-9290(86)90135-1 ↗
11. The mean shape of the human cornea10.1080/713820960 ↗
12. A comparison among Neo-Hookean model, Mooney-Rivlin model, and Ogden model for chloroprene rubber10.1007/s12541-012-0099-y ↗
13. Transport processes across the rabbit corneal epithelium: a review10.3109/02713688509025145 ↗
14. Wireless, passive strain sensor in a doughnut-shaped contact lens for continuous non-invasive self-monitoring of intraocular pressure10.1039/C9LC00735K ↗
15. Accuracy of transpalpebral tonometer compared to Goldmann applanation tonometer in normal and glaucomatous eyes
16. Glaucoma and its treatment: a review10.1093/ajhp/62.7.691 ↗
17. An introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations
18. Epidermal growth factor receptor in corneal damage: update and new insights from recent reports10.3109/15569527.2010.498398 ↗
19. The organization of collagen in the corneal stroma
20. Intraocular pressure
21. Measuring intraocular pressure10.1097/ICU.0000000000000129 ↗
22. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo10.1006/bulm.1999.0102 ↗
23. Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations10.1115/1.2982251 ↗
24. Nearly-incompressible transverse isotropy (NITI) of cornea elasticity: model and experiments with acoustic micro-tapping OCE10.1038/s41598-020-69909-9 ↗
25. The number of people with glaucoma worldwide in 2010 and 202010.1136/bjo.2005.081224 ↗
26. The pathophysiology and treatment of glaucoma A review10.1001/jama.2014.3192 ↗
27. Comparative analysis of rabbit cornea and human cornea histology
28. The global impact of glaucoma
29. The strain-energy function of a hyperelastic material in terms of the extension ratios10.1063/1.1710039 ↗
30. The pathophysiology and treatment of glaucoma: a review10.1001/jama.2014.3192 ↗
31. Biomechanical model of the human cornea: considering shear stiffness and regional variation of collagen anisotropy and density10.1016/j.jmbbm.2014.11.006 ↗
32. Mucin coatings prevent tissue damage at the cornea–contact lens interface
33. Nonlinear material properties of intact cornea and sclera10.1016/0014-4835(72)90139-X ↗
34. Development of a rabbit corneal equivalent using an acellular corneal matrix of a porcine substrate
35. An improved C4.5 algorithm using L’ hospital rule for large dataset10.17485/ijst/2018/v11i47/132538 ↗
36. A study on the biomechanical properties of pig corneas based on overall eyeball expansion experiments and simulations