journal article·2021-12

Real-time replication of three-dimensional and time-varying physiological loading cycles for bone and implant testing: A novel protocol demonstrated for the proximal human femur while walking

Saulo Martelli, John J. Costi

Publisher page

Abstract

In vitro real-time replication of three-dimensional, time-varying load profiles acting on human bones during physical activity can advance bone and implant testing protocols. This study aimed to develop a novel protocol for applying the three-dimensional, time-varying hip contact force while walking to a human femur specimen. The target force profile was obtained from the literature. A proximal femur from an elderly female donor was instrumented using ten rosette strain gages and tested using a custom-made hexapod robot. A load-control algorithm determined the robot position generating the target force at low frequency (0.0004 Hz). Five cycles of the robot position were played back at five intermediate frequencies up to real-time (0.04, 0.08, 0.16, 0.4, and 0.8 Hz). The hip reaction force, the length of the actuators (position), and cortical strains were compared. The error in the load-control force was 0.3 ± 4.2 N (mean ± SD). The last three force, position, and strain cycles varied by less than 1.1% for every frequency analyzed. Across frequencies, the force increased by 28% at 0.8 Hz as a logarithmic function of frequency (R2 = 0.98). The position and strain error linearly increased with frequency up to 0.4 Hz. The median position error and the interquartile range of the strain error reached 15% and 13% at 0.8 Hz. Changes of force and cortical strain at increasing frequencies were linearly related (R2 = 0.99). Therefore, the protocol developed can provide repeatable three-dimensional time-varying load profiles, although the comparison of the specimen deformation obtained across frequencies should be considered with care, particularly in the higher frequency range. This information supports the design of dynamic tests of bone and implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Orthopedic Infections and Treatments · Total Knee Arthroplasty Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (42)

Show source-provided references
1. In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur10.1002/jor.1100150620 ↗
2. Virtual trial to evaluate the robustness of cementless femoral stems to patient and surgical variation10.1016/j.jbiomech.2018.11.013 ↗
3. Biomechanical robustness of a contemporary cementless stem to surgical variation in stem size and position10.1115/1.4039824 ↗
4. Effect of degeneration on the six degree of freedom mechanical properties of human lumbar spine segments10.1002/jor.23334 ↗
5. Metal-on-Metal hybrid surface arthroplasty: two to six-year follow-up study10.2106/00004623-200401000-00006 ↗
6. Postoperative lower limb joint kinematics following tibial plateau fracture : a 2-year longitudinal study10.1016/j.gaitpost.2020.10.005 ↗
7. Hip contact forces and gait patterns from routine activities10.1016/S0021-9290(01)00040-9 ↗
8. Bone compressive strength: the influence of density and strain rate10.1126/science.996549 ↗
9. Effects of extracellular matrix viscoelasticity on cellular behaviour10.1038/s41586-020-2612-2 ↗
10. Properties of Bone
11. Structural behaviour and strain distribution of the long bones of the human lower limbs10.1016/j.jbiomech.2009.11.022 ↗
12. In vitro replication of spontaneous fractures of the proximal human femur10.1016/j.jbiomech.2007.03.015 ↗
13. Strain distribution in the proximal human femoral metaphysis10.1243/09544119JEIM497 ↗
14. Mechanical testing of bones: the positive synergy of finite-element models and in vitro experiments10.1098/rsta.2010.0046 ↗
15. Stiffness analysis and control of a Stewart platform-based manipulator with decoupled sensor-actuator locations for ultrahigh accuracy positioning under large external loads10.1115/1.4027945 ↗
16. Morphology based anisotropic finite element models of the proximal femur validated with experimental data10.1016/j.medengphy.2016.08.010 ↗
17. A new test rig for static and dynamic evaluation of knee motion based on a cable-driven parallel manipulator loading system10.1007/s11012-015-0124-1 ↗
18. Biomechanical behaviours of the bone-implant interface: a review10.1098/rsif.2019.0259 ↗
19. The effect of walking speed on quality of gait in older adults10.1016/j.gaitpost.2018.07.004 ↗
20. Age-dependence of femoral strength in white women and men10.1359/jbmr.091033 ↗
21. Mechanical loading of the femoral neck in human locomotion10.1002/jbmr.3529 ↗
22. Personalised 3D knee compliance from clinically viable knee laxity measurements: a proof of concept ex vivo experiment10.1016/j.medengphy.2018.12.003 ↗
23. Adaptive velocity-based six degree of freedom load control for real-time unconstrained biomechanical testing10.1016/j.jbiomech.2014.06.023 ↗
24. Simulating dynamic activities using a five-axis knee simulator10.1115/1.1846070 ↗
25. Modelling human locomotion to inform exercise prescription for osteoporosis10.1007/s11914-020-00592-5 ↗
26. Stochastic modelling of muscle recruitment during activity10.1098/rsfs.2014.0094 ↗
27. Sensitivity of femoral strain calculations to anatomical scaling errors in musculoskeletal models of movement10.1016/j.jbiomech.2015.08.001 ↗
28. Strain energy in the femoral neck during exercise10.1016/j.jbiomech.2014.03.036 ↗
29. Time-elapsed synchrotron-light microstructural imaging of femoral neck fracture10.1016/j.jmbbm.2018.05.016 ↗
30. Femoral shaft strains during daily activities: implications for atypical femoral fractures10.1016/j.clinbiomech.2014.08.001 ↗
31. Extensive risk analysis of mechanical failure for an epiphyseal hip prothesis: a combined numerical-experimental approach10.1243/09544119JEIM728 ↗
32. Dynamic response of bone and muscle tissue10.1152/jappl.1966.21.4.1231 ↗
33. A home exercise program for tibial bone strengthening based on in vivo strain measurements10.1097/00002060-200106000-00009 ↗
34. The impact of hip implant alignment on muscle and joint loading during dynamic activities10.1016/j.clinbiomech.2018.02.010 ↗
35. Body anthropometry and bone strength conjointly determine the risk of hip fracture in a sideways fall
36. A combined robotic/universal force sensor approach to determine in situ forces of knee ligaments10.1016/0021-9290(96)00056-5 ↗
37. To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?10.1016/j.jbiomech.2014.08.024 ↗
38. Femoral loads during gait in a patient with massive skeletal reconstruction10.1016/j.clinbiomech.2011.09.006 ↗
39. Finite element modeling of resurfacing hip prosthesis: estimation of accuracy through experimental validation10.1115/1.4000065 ↗
40. Strain Gauge Analysis of Hard Tissues: Factors Influencing Measurements
41. Asymmetric varus and valgus stability of the anatomic cadaver knee and the load sharing between collateral ligaments and bearing surfaces10.1115/1.4027662 ↗
42. Population-based bone strain during physical activity: a novel method demonstrated for the human femur10.1007/s10439-020-02483-3 ↗